{"product_id":"vibro-meter-gsi127-244-127-000-017-a2-b02-galvanic-separation-unit","title":"VIBRO-METER GSI127 244-127-000-017 A2-B02 Unidade de Separação Galvânica","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI127 244-127-000-017 (GSI127)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma unidade de separação galvânica de alto desempenho projetada para uso nas cadeias de proteção de máquinas e no\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVM600. Esta unidade serve como uma interface crítica de segurança e condicionamento de sinal, proporcionando isolamento elétrico entre os condicionadores de sinal montados no campo (como o IQS450) e o sistema de monitoramento (como a placa MPC4). Ao evitar loops de terra e proteger a eletrônica sensível contra transientes de alta tensão, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI 127\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarante a integridade dos dados de vibração e deslocamento nos ambientes industriais mais exigentes, incluindo usinas de energia e zonas perigosas de refinarias.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica (Detalhada)\u003c\/h3\u003e\n\u003cp\u003eA configuração\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e244-127-000-017 (A2-B02)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé especificamente adaptada para transmissão de sinal de alta precisão e distribuição de energia para sensores de campo.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolamento Galvânico:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtiliza acoplamento por transformador de alta integridade para fornecer isolamento triplo (entrada, saída e alimentação), eliminando efetivamente interferências de ruído causadas por diferenças de potencial de terra.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistribuição de Alimentação:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA unidade transfere energia intrinsecamente segura para o condicionador de sinal do lado do campo enquanto retorna um sinal isolado preciso de 4-20 mA ou tensão para a sala de controle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEspecificação A2-B02:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e*\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndica uma característica específica do sinal de saída (tipicamente uma faixa de saída de tensão otimizada para racks VM600).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB02:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigna a configuração de montagem e conexão, frequentemente com montagem em trilho DIN para fácil instalação em caixas de junção ou painéis de marshalling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProteção Ex:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProjetado para atuar como um aparelho associado, permitindo que a unidade interfira com sensores localizados em áreas perigosas Zona 0 ou Zona 1.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eGSI127 244-127-000-017\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuíça\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão de Isolamento\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4000 Vrms (Entrada para Saída)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTensão de Alimentação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de Saída\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTensão\/ Corrente (Dependente da configuração)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 a 70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMontagem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrilho DIN (35 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePor que a separação galvânica é necessária em uma cadeia de medição TQ402\/IQS450?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEm grandes instalações industriais, o potencial de terra em uma turbina (campo) e na sala de controle (rack) pode diferir por vários volts. Sem o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI127\u003c\/strong\u003e, essa diferença cria um loop de terra que injeta ruído na medição, levando a alertas falsos de vibração ou a falhas de máquinas mascaradas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO GSI127 244-127-000-017 requer calibração externa?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão. A unidade é um dispositivo de \"ganho unitário\" ou função de transferência fixa. É calibrada de fábrica para garantir que o sinal que entra na unidade do campo seja idêntico ao sinal que sai para o rack, mantendo um alto grau de linearidade.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO que acontece se a alimentação de 24 VDC para o GSI127 for interrompida?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA unidade deixará de transmitir o sinal. No entanto, seu design isolado garante que a falha de energia no lado da alimentação não cause curto-circuito ou surtos no circuito do sensor do lado do campo, protegendo seus transdutores caros.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiação Intrinsecamente Segura:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAssegure que os terminais \"Azul\" (área perigosa) estejam fisicamente separados dos terminais \"Cinza\/Preto\" (área segura) por pelo menos 50 mm, ou utilize uma barreira física. Este é um requisito obrigatório para manter a certificação Ex-i do circuito.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento do Trilho DIN:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmbora o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI127\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eforneça isolamento galvânico, o próprio trilho DIN deve ser conectado a um aterramento de instrumento de alta integridade. Isso oferece um caminho para qualquer interferência eletromagnética (EMI) capturada pela blindagem interna da unidade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento de Calor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAo instalar múltiplas unidades\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI127\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eem uma única caixa de junção, mantenha um espaçamento mínimo de 5 mm entre as unidades para permitir convecção passiva, pois os conversores DC\/DC internos geram uma pequena quantidade de calor durante a operação.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI127\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ese destaca por sua tecnologia de\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeslocamento de Fase Ultra-Baixo\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. No monitoramento de vibração, o tempo (fase) do sinal é tão importante quanto a amplitude para diagnósticos como a \"Análise de Órbita\". Diferente dos isoladores industriais padrão, o GSI127 é projetado para manter a integridade da fase do sinal até 20 kHz, garantindo que seus diagnósticos de máquinas sejam baseados em formas de onda precisas e não distorcidas.\u003c\/p\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695211114859,"sku":"GSI127 244-127-000-017 A2-B02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-gsi127-244-127-000-017-a2-b02-galvanic-separation-unit-adaknxup3o4_a39a9750-f65c-442b-a97a-5a92fc85b878.jpg?v=1766130837","url":"https:\/\/www.plcprotech.com\/pt\/products\/vibro-meter-gsi127-244-127-000-017-a2-b02-galvanic-separation-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}