{"product_id":"vibro-meter-ipc-704-244-704-000-042-charge-to-current-signal-conditioner","title":"VIBRO-METER IPC 704 244-704-000-042 Condicionador de Sinal Carga para Corrente","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPC 704 (244-704-000-042)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um condicionador de sinal de alta precisão projetado especificamente para interfacear com\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCA xxx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacelerômetros piezoelétricos e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP xxx\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esensores de pressão dinâmica. Como componente central da linha de produtos\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, ele converte sinais baseados em carga de alta impedância em saídas estáveis de corrente ou tensão. Essa conversão é vital para\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Instrumentação Supervisória de Turbinas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ee monitoramento de condição, pois permite a transmissão confiável do sinal por distâncias de até 1 km usando cabeamento padrão, protegendo efetivamente dados críticos contra interferências eletromagnéticas comuns em usinas e ambientes industriais.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica (Detalhes)\u003c\/h3\u003e\n\u003cp\u003eA configuração\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e244-704-000-042\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresenta uma construção de hardware versátil destinada à confiabilidade industrial extrema.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmplificação de Carga:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO equipamento funciona como um amplificador de carga de alto ganho que aceita sinais em picocoulombs (pC) e fornece uma saída de baixa impedância.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArquitetura de Filtragem:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePossui filtros passa-alta e passa-baixa configuráveis para restringir a faixa de frequência às assinaturas mecânicas específicas de interesse, como frequências de passagem de lâminas ou desgaste de rolamentos.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegração Opcional:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEste modelo pode ser configurado com um integrador interno, permitindo converter dados de aceleração em unidades de velocidade (mm\/s ou in\/s) diretamente antes da transmissão.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmissão de Sinal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtiliza uma técnica de modulação de corrente, que é inerentemente mais resistente a quedas de tensão e ruído elétrico do que sistemas tradicionais baseados em tensão.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProteção RFI\/EMI:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA carcaça de alumínio moldado atua como uma gaiola de Faraday, enquanto filtros internos de RFI protegem os estágios de entrada\/saída contra interferência de radiofrequência.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIPC 704 (244-704-000-042)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuíça\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibilidade de Entrada\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCA xxx (Acelerômetros), CP xxx (Pressão)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFaixa de Frequência\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,5 Hz a 20 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de Saída\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCorrente de 2 fios ou tensão de 3 fios\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 a 85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaterial da Carcaça\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlumínio Moldado\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertificação para Áreas Perigosas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI, cCSAus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo a modulação de corrente beneficia o monitoramento a longa distância?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAo usar modulação de corrente, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPC 704\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarante que a precisão do sinal não seja degradada pela resistência de cabos longos. Isso permite que o condicionador seja instalado em uma caixa de junção próxima à máquina, enquanto a eletrônica de processamento (como um rack\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e) esteja localizada até 1.000 metros de distância em uma sala de controle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eÉ necessário um dispositivo de separação galvânica para este condicionador?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSim, ao usar a configuração de transmissão por corrente, uma unidade de separação galvânica\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé necessária para fornecer a alimentação e isolamento necessários ao circuito, garantindo proteção contra loops de terra.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a função da verificação \"Sensor OK\" no IPC 704?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO condicionador monitora a tensão de polarização do transdutor conectado. Se o sensor ou o cabo de entrada estiverem em curto ou circuito aberto, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPC 704\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eajustará sua saída para um nível de erro predefinido, permitindo que o sistema de monitoramento dispare um alarme de \"Falha no Sensor\" em vez de um desligamento falso por vibração.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRequisitos do Cabo de Entrada:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComo sensores piezoelétricos produzem sinais de alta impedância, o cabo entre o sensor e o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPC 704\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeve ser um cabo coaxial de baixo ruído especializado ou cabo mineral isolado (MI). Fiação industrial padrão neste segmento causará ruído significativo devido ao efeito triboelétrico.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguração do Filtro:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAntes da comissionamento, verifique as configurações dos jumpers ou ligações de solda para os filtros passa-alta e passa-baixa. Para vibração típica de turbinas a gás, uma configuração passa-alta de 10 Hz é frequentemente usada para eliminar o \"lavagem\" térmico de baixa frequência.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento da Carcaça:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA carcaça de alumínio deve estar firmemente conectada ao aterramento local do instrumento. Se montada em trilho DIN, certifique-se de que o próprio trilho tenha um caminho de baixa resistência até a terra para maximizar a eficácia dos filtros internos de RFI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPC 704 244-704-000-042\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ese destaca por seu\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlto Alcance Dinâmico\u003c\/strong\u003e. É capaz de processar pulsações mínimas de pressão em câmaras de combustão e vibrações estruturais intensas simultaneamente sem saturar o amplificador. Seu circuito projetado na Suíça oferece uma capacidade de \"Partida a Frio\", alcançando precisão de medição estabilizada em segundos após a energização, o que é crítico para monitorar ativos que passam por ciclos rápidos de partida.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695206887787,"sku":"IPC704 244-704-000-042","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-ipc704-244-704-000-042-signal-conditioner-gqqkpucqxyz_115d7ab8-f7e2-4c91-9e82-9cda418cc766.jpg?v=1766130717","url":"https:\/\/www.plcprotech.com\/pt\/products\/vibro-meter-ipc-704-244-704-000-042-charge-to-current-signal-conditioner","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}