{"product_id":"vm600-cpum-200-595-033-111-vibro-meter-modular-cpu-card","title":"VM600 CPUM 200-595-033-111 Placa CPU Modular Vibro-Meter","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVM600 CPUM (200-595-033-111)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé o controlador principal do rack e gateway de comunicações para o sistema de proteção de máquinas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter VM600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Como a \"inteligência\" do rack, esta placa modular de CPU gerencia o fluxo de dados entre as placas de medição individuais (como a MPC4 ou AMC6) e os sistemas de controle externos. Ela oferece capacidades essenciais de rede, incluindo comunicações Ethernet e seriais, permitindo configuração remota, monitoramento de condição e diagnóstico do sistema. Em um ambiente crítico de missão\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSI (Instrumentação Supervisória de Turbinas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM 200-595-033-111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarante que os dados de status e eventos de alarme sejam registrados e transmitidos com alta integridade para o sistema DCS ou SCADA da planta.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica (Detalhada)\u003c\/h3\u003e\n\u003cp\u003eA variante\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200-595-033-111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresenta uma revisão específica de hardware e firmware da plataforma CPUM, frequentemente utilizada em configurações de alta disponibilidade.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMestre do Barramento VME:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAtua como controlador mestre do backplane VM600, coordenando a sincronização de todas as placas de monitoramento e gerenciando o tráfego interno do barramento VME.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePortas de Comunicação Duplas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipado com interfaces Ethernet (10\/100Base-T) e RS-232\/RS-485 para suportar vários protocolos industriais, incluindo Modbus TCP e Modbus RTU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface do Painel Frontal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePossui uma porta dedicada de \"Configuração\" e LEDs de diagnóstico que fornecem feedback visual imediato sobre a saúde do rack, status da comunicação e carga da CPU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArquitetura Modular:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProjetado para ser emparelhado com uma placa correspondente\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIOCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Comunicação de Entrada\/Saída) na parte traseira do rack para facilitar conexões físicas externas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParâmetro\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetalhes da Especificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModelo\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCPUM 200-595-033-111\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMarca\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibro-Meter (Meggitt)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigem\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuíça\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTipo de Processador\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eArquitetura RISC de alta velocidade\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocolos de Comunicação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP, Modbus RTU, Proprietário VM600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperatura de Operação\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 a 65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeso\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLargura do Slot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSlot Único (VME padrão 6U)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConsumo de Energia\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 W (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo faço para atualizar o firmware do CPUM 200-595-033-111?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs atualizações de firmware devem ser realizadas via porta de configuração do painel frontal usando o software\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVibro-Meter MPS (Sistema de Proteção de Máquinas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Certifique-se de que o rack esteja no modo \"Bypass\" antes de iniciar a transferência para evitar interrupção do barramento de segurança.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO CPUM controla os relés de disparo nas placas MPC4?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé uma placa de gerenciamento e comunicação. A lógica de disparo e a execução dos relés são tratadas localmente pelas placas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMPC4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara garantir que a função de segurança permaneça autônoma mesmo se o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efalhar.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eO que devo fazer se o LED \"Status\" piscar em vermelho?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUm LED vermelho piscando normalmente indica uma incompatibilidade de configuração ou um erro de comunicação no barramento VME. Use os logs do sistema no software MPS para identificar qual placa no rack está falhando na comunicação com o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePosicionamento do Slot:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM 200-595-033-111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeve ser instalado no \"Slot Controlador\" designado do rack VM600 (normalmente o slot mais à esquerda, Slot 0 ou 1). Certifique-se de que as alças ejetoras estejam totalmente encaixadas para garantir uma conexão segura com o backplane VME.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGerenciamento de Endereço IP:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDurante a comissionamento, atribua um endereço IP estático ao\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara evitar perda de comunicação com o DCS. Evite usar DHCP em redes de infraestrutura crítica.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlanejamento de Redundância:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEm configurações \"Dual-Rack\" ou de \"Alta Disponibilidade\", duas placas\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epodem ser usadas para fornecer redundância de comunicação. Certifique-se de que ambas as placas estejam executando revisões de firmware idênticas para manter a sincronização.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVantagens de Engenharia\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUM 200-595-033-111\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ese destaca pelo seu design de\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGateway Ciber-Resiliente\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e. Ele atua como um buffer entre o sensível barramento interno de segurança e a rede externa da planta, protegendo a lógica de proteção das máquinas contra interferências oriundas da rede. Além disso, seu processamento de alta velocidade permite o manuseio simultâneo de requisições Modbus do DCS e fluxos de dados de alta resolução para o software de monitoramento de condição sem latência, proporcionando uma ponte perfeita entre proteção e predição.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"VIBRO-METER","offers":[{"title":"Default Title","offer_id":52695212622187,"sku":"VM600 CPU M 200-595-033-111","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/vibro-meter-vm600-cpu-m-200-595-033-111-cpum-modular-cpu-card-rxv4ejbqubb_1ed4bd63-ef88-4104-95c3-14adf76241f9.jpg?v=1766130873","url":"https:\/\/www.plcprotech.com\/pt\/products\/vm600-cpum-200-595-033-111-vibro-meter-modular-cpu-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}