{"product_id":"weidmuller-1504250000-ie-sw-bl06-1tx-4poe-1sc-basic-line-unmanaged-poe-ethernet-switch","title":"Switch Ethernet PoE Não Gerenciado Basic Line Weidmuller 1504250000 IE-SW-BL06-1TX-4POE-1SC","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nIntegrando-se perfeitamente em arquiteturas industriais de controle rigorosas, o switch Ethernet não gerenciado Weidmuller IE-SW-BL06-1TX-4POE-1SC facilita a transmissão robusta de dados e fornecimento de energia. Esta variante de hardware, identificada pelo número da peça 1504250000, possui \u003cstrong\u003equatro portas Power over Ethernet (PoE)\u003c\/strong\u003e, \u003cstrong\u003euma porta padrão Fast Ethernet de cobre\u003c\/strong\u003e e \u003cstrong\u003euma porta de fibra óptica multimodo SC-Duplex\u003c\/strong\u003e para suportar comunicação de longa distância de até 5 km.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003ePrincipais Características\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eQuatro portas PoE compatíveis com IEEE 802.3af\/at para alimentação simplificada de dispositivos de campo.\u003c\/li\u003e\n  \u003cli\u003eUma porta de fibra multimodo 100BaseFX com conector SC-Duplex para uplinks de longa distância imunes a ruídos.\u003c\/li\u003e\n  \u003cli\u003eEntradas de energia dupla redundante (12\/24\/48 V DC) para maximizar o tempo de atividade do sistema.\u003c\/li\u003e\n  \u003cli\u003eCarcaça de alumínio com classificação IP30 projetada para montagem em trilho DIN economizando espaço.\u003c\/li\u003e\n  \u003cli\u003eArquitetura de comutação Store-and-Forward com tabela MAC de 2 K endereços.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAplicações Industriais Pesadas\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eSistemas industriais de vigilância IP e segurança em plantas de manufatura.\u003c\/li\u003e\n  \u003cli\u003eIntegração de ponto de acesso WLAN em ambientes de armazém.\u003c\/li\u003e\n  \u003cli\u003eRede de nós de sistema de controle distribuído (DCS) em instalações de água\/esgoto.\u003c\/li\u003e\n  \u003cli\u003eMonitoramento de tráfego e estações de telemetria externas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eParâmetro\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eValor da Especificação\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFabricante\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNúmero da Peça\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1504250000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCódigo do Modelo\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIE-SW-BL06-1TX-4POE-1SC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTipo de Switch\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePoE não gerenciado\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTotal de Portas\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e6\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePortas PoE\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e4x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePortas de Cobre\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x RJ45 (10\/100BaseT(X))\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePortas de Fibra\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x SC-Duplex Multimodo (100BaseFX)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDistância de Transmissão\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5 km (típico)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTaxa de Transmissão\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e100 Mbps\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTensão de Entrada\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e12\/24\/48 V DC (Entradas redundantes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCorrente de Inrush\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e64,56 A a 48 V DC (0,1 a 1 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTipo de Conexão\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1x Bloco terminal removível de 4 pinos\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTamanho da Tabela MAC\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTamanho do Buffer de Pacotes\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e768 kBit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMaterial da Carcaça\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAlumínio\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eClasse de Proteção\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTemperatura de Operação\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-10 °C a 60 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTemperatura de Armazenamento\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-40 °C a 85 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eUmidade de Operação\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5% a 95% (sem condensação)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDimensões (L x A x P)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e50 mm x 115 mm x 70 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePeso Líquido\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e375 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePeso para Envio (Calculado)\u003c\/td\u003e\n        \u003ctd style=\"padding: 1.00g;\"\u003e1,0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConexões e Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eTerminal \/ Porta\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold;\"\u003eFunção \/ Atribuição\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePino 1 (Bloco Terminal de 4 Pinos)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1+ (Entrada de Energia Primária)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePino 2 (Bloco Terminal de 4 Pinos)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV1- (Terra da Energia Primária)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePino 3 (Bloco Terminal de 4 Pinos)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2+ (Entrada de Energia Redundante)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePino 4 (Bloco Terminal de 4 Pinos)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eV2- (Terra de Alimentação Redundante)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePortas 1 a 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePorta 10\/100BaseT(X) RJ45 com Injetor PoE\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePorta 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePorta de Cobre Padrão 10\/100BaseT(X) RJ45\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePorta 6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePorta de Fibra Multimodo SC-Duplex 100BaseFX\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInsights Empíricos de Engenharia\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eModelos Alternativos e Compatibilidade\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nA série IE-SW-BL06 serve como substituição direta para configurações antigas da série IE-SW-BL05 quando a injeção PoE é necessária na borda. Certifique-se de que as fontes de alimentação existentes sejam classificadas para o orçamento total de PoE (tipicamente 15,4W por porta para PoE padrão) mais o consumo interno do switch.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eArmamentos e Notas de Engenharia para Aplicação\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nAo operar na extremidade inferior da faixa de tensão de entrada (12V ou 24V DC), verifique se o conversor interno step-up pode fornecer estável os 48V DC necessários para conformidade PoE aos PDs (Dispositivos Alimentados) conectados. Em ambientes de alta vibração, certifique-se de que o clipe do trilho DIN esteja travado com segurança e os parafusos do bloco terminal de 4 pinos estejam apertados com torque de 0,5 Nm para evitar perda intermitente de energia.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.25rem;\"\u003eDicas para Comissionamento e Fiação\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nSempre use cabos de par trançado blindado (STP) Cat5e ou Cat6 para as portas de cobre para mitigar interferência eletromagnética (EMI) em painéis de alta tensão. A porta de fibra SC-Duplex deve ser limpa com um limpador aprovado para conectores de fibra óptica antes da inserção para evitar atenuação do sinal ao longo do percurso máximo de 5 km.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eDiretrizes de Instalação\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003e\n    AVISO CRÍTICO: Desligue todas as fontes de energia antes de tentar a instalação, fiação ou manutenção. Certifique-se de que as linhas de alimentação redundantes estejam completamente isoladas. O não cumprimento desses protocolos pode resultar em choque elétrico, danos ao equipamento ou tempo de inatividade inesperado do sistema.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMonte o switch em um trilho DIN TS 35 padrão, garantindo que o gancho superior encaixe primeiro no trilho, depois pressione para baixo até que a trava encaixe no lugar.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConecte o parafuso de aterramento funcional na carcaça de alumínio ao sistema local de terra de proteção (PE) usando um fio mínimo de 14 AWG.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eLigue as fontes de alimentação redundantes ao bloco terminal removível de 4 pinos, verificando a polaridade correta para as entradas V1 e V2.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eInsira o bloco terminal no soquete do switch e fixe os parafusos de retenção.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConecte os cabos de cobre RJ45 e o cabo de fibra óptica multimodo SC-Duplex em suas respectivas portas.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102123254123,"sku":"IE-SW-BL06-1TX-4POE-1SC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-bl06-1tx-4poe-1sc-tvtmcarvlvx.png?v=1776137753","url":"https:\/\/www.plcprotech.com\/pt\/products\/weidmuller-1504250000-ie-sw-bl06-1tx-4poe-1sc-basic-line-unmanaged-poe-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}