{"product_id":"weidmuller-1504370000-ie-sw-vl05m-3tx-2st-managed-industrial-ethernet-switch","title":"Weidmuller 1504370000 IE-SW-VL05M-3TX-2ST Managed Industrial Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Managing deterministic data distribution across harsh manufacturing environments is the primary function of the \u003cstrong\u003eWeidmuller 1504370000 IE-SW-VL05M-3TX-2ST\u003c\/strong\u003e managed industrial Ethernet switch. This high-performance network node integrates copper and fiber interfaces to bridge long-distance field segments while maintaining robust electromagnetic immunity. Encased in a rugged metal housing, it provides reliable \u003cstrong\u003eStore and Forward\u003c\/strong\u003e data switching for time-critical automation architectures.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManaged Network Control:\u003c\/strong\u003e Comprehensive configuration options for traffic prioritization, VLAN segmentation, and ring redundancy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHybrid Port Configuration:\u003c\/strong\u003e Features 3 RJ45 Fast Ethernet ports and 2 Multimode fiber ports with ST-Duplex connectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Optical Range:\u003c\/strong\u003e Supports reliable fiber optic transmission distances up to 5 km.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Redundancy:\u003c\/strong\u003e Dual redundant 12\/24\/48 V DC power inputs ensure continuous operation during primary supply failures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial-Grade Build:\u003c\/strong\u003e IP30-rated metal chassis designed to withstand high mechanical vibration and thermal stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eHeavy Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWind Power Generation:\u003c\/strong\u003e Linking nacelle control systems to ground-level SCADA networks over optical fiber.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater and Wastewater Treatment:\u003c\/strong\u003e Connecting distributed PLC nodes across large physical footprints without electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and Gas Processing:\u003c\/strong\u003e Safe deployment in control cabinets requiring robust thermal management and redundant power feeds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e High-speed machine-to-machine (M2M) communication on standard DIN rail assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-VL05M-3TX-2ST\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504370000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eManaged\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTransmission Speed\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e100 Mbps (Fast Ethernet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRJ45 Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e3x 10\/100BaseT(X)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eFiber Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2x Multimode (ST-Duplex)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eTypical Fiber Distance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 km\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMAC Table Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e2 K\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePacket Buffer Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 Mbit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e12 \/ 24 \/ 48 V DC (Redundant Inputs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1x Removable 6-pin terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eMetal (IP30 Protection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDIN rail, Panel (with optional mounting kit)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-10 degC to 60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eAmbient Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e53.6 mm x 135 mm x 105 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e650 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.5 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTerminal Block Pin Assignment\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003ePin Number\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eSignal Designation\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.5rem; font-weight: bold;\"\u003eFunctional Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary DC Power Input (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV1-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary DC Power Input (-)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFault\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRelay Contact (Normally Closed on failure)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eFault\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eRelay Contact (Normally Closed on failure)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2+\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSecondary Redundant DC Power Input (+)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003e6\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eV2-\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eSecondary Redundant DC Power Input (-)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  The IE-SW-VL05M-3TX-2ST managed switch is a direct functional upgrade over unmanaged variants such as the IE-SW-VL05-3TX-2ST. When replacing an unmanaged switch with this managed unit, network administrators must configure the IP address and disable unused protocols to prevent broadcast storms. Ensure that the remote fiber transceiver matches the 1300 nm wavelength specification of this device's multimode ST ports.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  In high-temperature environments exceeding 50 degC, natural convection cooling is critical. Avoid mounting this switch directly adjacent to high-heat-dissipating components like power supplies or motor drives; maintain a minimum clearance of 25 mm on both sides. When calculating the fiber optic power budget, factor in a typical 5 km limit and account for connector attenuation (typically 0.75 dB per ST junction) to prevent signal degradation.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\n  Always ground the IP30 metal chassis using the dedicated grounding screw located on the top panel to establish a low-impedance path for electrostatic discharge. When wiring redundant power supplies, connect V1 and V2 to separate physical power sources. This configuration allows the internal fault relay to trip and signal an external PLC alarm immediately if one of the power loops loses voltage.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all electrical power sources before attempting to wire or mount the switch. Do not plug or unplug the 6-pin terminal block while circuits are live, as this can cause electrical arcing and damage internal components.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eSnap the switch onto a standard TS 35 DIN rail, ensuring the DIN rail clip locks firmly into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect a dedicated grounding wire (minimum 14 AWG) from the chassis ground screw to the main cabinet earth ground.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eWire the 12\/24\/48 V DC power lines to the removable 6-pin terminal block, then insert the block firmly into the switch socket.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 1rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eInsert the RJ45 copper communication cables and the ST-Duplex multimode fiber optic connectors into their respective ports.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127579499,"sku":"IE-SW-VL05M-3TX-2ST","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-vl05m-3tx-2st-a2e2rkxptss.png?v=1776137763","url":"https:\/\/www.plcprotech.com\/pt\/products\/weidmuller-1504370000-ie-sw-vl05m-3tx-2st-managed-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}