{"product_id":"weidmuller-1504420000-ie-sw-ip67t-5m12-unmanaged-industrial-ethernet-switch","title":"Weidmuller 1504420000 IE-SW-IP67T-5M12 Unmanaged Industrial Ethernet Switch","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned for decentralized, cabinet-free installation in demanding environments, the \u003cstrong\u003eWeidmuller 1504420000\u003c\/strong\u003e (model \u003cstrong\u003eIE-SW-IP67T-5M12\u003c\/strong\u003e) provides reliable Fast Ethernet distribution directly on machinery. This unmanaged switch features a fully encapsulated plastic housing with an \u003cstrong\u003eIP67 ingress protection rating\u003c\/strong\u003e, eliminating the need for protective junction boxes and reducing field wiring complexity.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eFive 10\/100BaseT(X) ports utilizing robust M12 D-coded female connectors.\u003c\/li\u003e\n  \u003cli\u003eIP67-rated encapsulated plastic housing resistant to dust, moisture, and temporary water immersion.\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range from -40 degC to 75 degC for extreme thermal environments.\u003c\/li\u003e\n  \u003cli\u003eFlexible power supply options supporting 24\/36 V DC or 24 V AC via an A-coded M12 connector.\u003c\/li\u003e\n  \u003cli\u003eIntegrated overload current protection (1.1 A) and reverse polarity protection.\u003c\/li\u003e\n  \u003cli\u003eStore-and-Forward switching architecture with wire-speed forwarding rates.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eHeavy Industrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomotive Assembly:\u003c\/strong\u003e Direct mounting on robotic arms and welding cells where space is limited.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFood \u0026amp; Beverage:\u003c\/strong\u003e Washdown areas requiring dust-tight and water-resistant networking hardware.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Decentralized conveyor control and sorting systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOutdoor Infrastructure:\u003c\/strong\u003e Exposed field installations subject to wide temperature fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1504420000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIE-SW-IP67T-5M12\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSwitch Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eUnmanaged\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEthernet Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5 x M12 D-coded (Female, 4-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 x M12 A-coded (Male, 5-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e24\/36 V DC, 24 V AC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.12 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOverload Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.1 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eReverse Polarity Protection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eAvailable\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePlastic (Encapsulated)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP67\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eMounting Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWall mounting (screwed in)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 75 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-40 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e60 mm x 125 mm x 29.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e270 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eInterface Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnector Specification\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003ePin Assignment \/ Function\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEthernet Ports (1 to 5)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eM12 Female, D-coded, 4-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 1: TD+, Pin 2: RD+, Pin 3: TD-, Pin 4: RD-\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Input Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eM12 Male, A-coded, 5-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePin 1: V+, Pin 2: V+, Pin 3: V-, Pin 4: V-, Pin 5: FE (Functional Earth)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem; font-weight: bold;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IE-SW-IP67T-5M12 serves as a direct upgrade path for older IP30 or IP20 DIN-rail switches when migrating to decentralized, cabinet-free field architectures. Ensure that all mating patch cables are industrial-grade, double-shielded Cat5e or higher with molded M12 D-coded connectors to maintain signal integrity in high-EMI environments.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem; font-weight: bold;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile the encapsulated plastic housing is highly resilient to moisture, it is not rated for continuous high-pressure washdowns (IP69K). For washdown zones, mount the switch in a semi-protected location or shield it from direct high-pressure spray. Unused M12 ports must be sealed with IP67-rated protective caps to prevent moisture ingress and internal pin corrosion.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2d3748; margin-top: 1rem; margin-bottom: 0.5rem; font-weight: bold;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use a calibrated torque wrench to tighten the M12 connectors to the manufacturer-recommended 0.6 Nm. Under-tightening compromises the IP67 seal, while over-tightening can strip the plastic threads or deform the internal O-ring. Ensure Pin 5 (FE) of the power connector is connected to a low-impedance local ground point to minimize noise coupling.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 1px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0;\"\u003eCRITICAL WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0.5rem 0 0 0;\"\u003eDisconnect all power sources before mounting or servicing the switch. Failure to de-energize the system prior to connection or disconnection of M12 cables can result in electrical arcing, damage to the internal transceiver components, or personal injury.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003ePosition the switch on a flat, rigid mounting surface. Secure the unit using the integrated mounting holes with appropriate M4 screws.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the functional earth (FE) wire to Pin 5 of the power cable, ensuring a low-resistance path to the machine ground.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eAlign and plug in the M12 A-coded power cable. Hand-tighten, then torque to exactly 0.6 Nm.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eConnect the M12 D-coded Ethernet cables to the active ports. Seal all unused ports with IP67 protective caps.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102127055211,"sku":"IE-SW-IP67T-5M12","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ie-sw-ip67t-5m12-pppbuq0fw5r.png?v=1776137762","url":"https:\/\/www.plcprotech.com\/pt\/products\/weidmuller-1504420000-ie-sw-ip67t-5m12-unmanaged-industrial-ethernet-switch","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}