{"product_id":"weidmuller-8965500000-act20-feed-in-pro-s-act20-series-power-feed-in-module","title":"Weidmuller 8965500000 ACT20-FEED-IN-PRO-S ACT20 Series Power Feed-In Module","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nDesigned to optimize power distribution within modular DIN-rail systems, the \u003cstrong\u003eWeidmuller 8965500000 ACT20-FEED-IN-PRO-S\u003c\/strong\u003e provides a centralized feed-in point for the ACT20 series and CH20M bus system. This high-efficiency module simplifies cabinet wiring by distributing supply voltage directly to adjacent modules via the rail bus, reducing point-to-point wiring and minimizing installation time.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eHigh efficiency rating exceeding 97.9% to minimize thermal dissipation inside the enclosure.\u003c\/li\u003e\n  \u003cli\u003eWide input voltage range of 19.2 V DC to 31.2 V DC for compatibility with standard 24 V DC industrial power supplies.\u003c\/li\u003e\n  \u003cli\u003eIntegrated screw connection technology ensuring secure, vibration-resistant field wiring.\u003c\/li\u003e\n  \u003cli\u003eSupports collective error signaling and status monitoring for enhanced system diagnostics.\u003c\/li\u003e\n  \u003cli\u003eCompact 22.5 mm width matching standard ACT20 series form factor to optimize DIN-rail space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.25rem;\"\u003e\n  \u003cli\u003eCentralized power distribution in industrial automation control panels.\u003c\/li\u003e\n  \u003cli\u003eSignal conditioning and isolation racks utilizing the CH20M rail bus system.\u003c\/li\u003e\n  \u003cli\u003eProcess industries requiring dense, modular DIN-rail instrument configurations.\u003c\/li\u003e\n  \u003cli\u003ePower grouping and segment isolation in complex PLC and DCS I\/O systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eWeidmuller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eArticle Number (SKU)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e8965500000\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eACT20-FEED-IN-PRO-S\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProduct Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePower Feed-In Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eSupply Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e19.2 to 31.2 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e\u0026lt;= 2.0 W\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eEfficiency\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e\u0026gt; 97.9%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eConnection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eScrew connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eProtection Degree\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e-20 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0% to 95% (non-condensing)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e119.2 mm x 22.5 mm x 113.6 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e0.140 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003e1.20 kg (including protective packaging)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 0.5rem; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eInput + \/ -\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003ePrimary 24 V DC supply input connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eCH20M Bus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eDirect power distribution contacts to the DIN-rail bus\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.5rem; font-weight: bold;\"\u003eStatus Relay\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.5rem;\"\u003eCollective error message output (normally closed \/ normally open contact)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe ACT20-FEED-IN-PRO-S is fully compatible with all Weidmuller ACT20 series signal converters and isolators that utilize the CH20M DIN-rail bus. It can replace standard passive feed-in terminals when active collective error monitoring and diagnostic feedback are required for the control system.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nEnsure that the total current drawn by all modules connected to the CH20M bus does not exceed the maximum bus current rating (typically 4 A). If your module configuration exceeds this limit, you must install an additional feed-in module to segment the power distribution groups.\n\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhen wiring the collective error relay, integrate the contact into your PLC's safety loop or alarm input. This ensures that any power loss or module fault on the CH20M bus is instantly flagged in the control room, reducing troubleshooting downtime.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; border-bottom: 2px solid #2b6cb0; padding-bottom: 0.25rem; margin-top: 1.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    De-energize all primary and auxiliary power sources before mounting, removing, or wiring the module. Ensure the DIN-rail bus contacts are completely clean and properly aligned before snapping the unit onto the rail to prevent physical damage to the contact pins.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the CH20M DIN-rail bus elements onto the TS 35 DIN rail if they are not already installed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the ACT20-FEED-IN-PRO-S with the rail and snap it firmly into place, ensuring the bus connector pins seat correctly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 V DC input supply lines to the designated screw terminals using the correct wire gauge and torque specifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 1.75rem; height: 1.75rem; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the collective error relay output to your supervisory control system for active diagnostic monitoring.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":53102130594155,"sku":"8965500000","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/8965500000-gdquort342v.png?v=1776137171","url":"https:\/\/www.plcprotech.com\/pt\/products\/weidmuller-8965500000-act20-feed-in-pro-s-act20-series-power-feed-in-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}