{"product_id":"yokogawa-adv142-p13-s1-centum-vp-ac-digital-input-module","title":"Módulo de Entrada Digital AC Yokogawa ADV142-P13 S1 CENTUM VP","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142-P13 S1 (ADV142)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um módulo de entrada digital isolada robusto de 16 canais, projetado para o sistema de controle distribuído (DCS) Yokogawa CENTUM VP. Especificamente desenvolvido para interfacear com sinais de alta tensão de 200 V a 240 V CA, este módulo é essencial para monitorar o status de equipamentos industriais pesados, como partidas de motor, painéis de comando e atuadores de grande porte. O\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epossui lógica integrada de entrada por botão de pressão, permitindo a contagem precisa das bordas dos sinais em aplicações de interface com operador. Esta unidade é construída para extrema confiabilidade, apresentando revestimento conformal padrão ISA G3 para resistir a gases corrosivos e uma faixa de temperatura operacional estendida de -20 a 70 °C. Ao suportar configurações duplamente redundantes e fornecer isolamento galvânico de alto nível, o módulo garante monitoramento contínuo do processo e reduz significativamente o risco de paradas não planejadas em ambientes severos, como refinarias de petróleo, usinas de energia e instalações de processamento químico.\u003c\/p\u003e\n\u003ch3\u003eDetalhamento do Sufixo\u003c\/h3\u003e\n\u003cp\u003eOs códigos de sufixo do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142-P13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefinem seu endurecimento de hardware especializado e capacidades funcionais:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipado com a função de Entrada por Botão de Pressão, permitindo que o módulo detecte e conte as bordas dos sinais de botão de pressão com um tempo mínimo de detecção dedicado.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCategorizado como tipo de uso geral, otimizado para detecção padrão de CA de alta tensão dentro do subsistema FIO.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInclui a opção de resistência à corrosão padrão ISA G3 e a opção de temperatura ambiente estendida (-20 a 70 °C).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigna a revisão de hardware Estilo 1, garantindo compatibilidade com as unidades de nó CENTUM VP atuais e E\/S de rede de campo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaracterística\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModelo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eADV142-P13 S1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarca\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapão\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCanais de Entrada\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16, isolados (8 canais por comum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensão Nominal de Entrada\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 a 240 V CA (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensão de Entrada LIGADA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 V CA (226 V Pico) a 264 V CA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensão de Entrada DESLIGADA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 V CA (56 V Pico) ou menos\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensão de Resistência\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kV CA (Entrada para Sistema) \/ 1,35 kV CA (Entre Comuns)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTemperatura Operacional\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 a 70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eClassificação Ambiental\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePadrão ISA G3 (Revestimento Conformal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeso\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAprox. 0,30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eComo a opção G3 beneficia a vida útil do módulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA opção G3 aplica um revestimento conformal especializado que protege os circuitos internos contra corrosão atmosférica causada por gases como Sulfeto de Hidrogênio (H2S), Cloro (Cl2) e Dióxido de Nitrogênio (NO2), comuns em fábricas de papel e estações de tratamento de água.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual é o requisito crítico de fase para a fiação deste módulo?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTodos os sinais de entrada CA conectados ao mesmo lado comum negativo (-) (agrupados a cada 8 canais) devem estar na mesma fase elétrica. Conectar múltiplas fases a um único comum pode causar falha catastrófica do hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEste módulo pode lidar com sinais de pulso de alta frequência?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNão. Embora o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etenha função de contagem por botão de pressão, ele é limitado a um ciclo máximo de 2,5 Hz. Para contagem de pulso em alta velocidade (até 10 kHz), é necessário um módulo de entrada de pulso dedicado, como o AAP135.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSegurança em Alta Tensão:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessa potenciais de até 264 V CA. Certifique-se de que toda a energia de campo esteja isolada antes de fazer a fiação dos terminais de pressão. Use fios com seção transversal de 1,25 mm² ou menor e verifique se as tampas dos terminais estão instaladas com segurança para evitar contato acidental.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsiderações Térmicas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAo operar no limite superior da faixa de temperatura (até 70 °C), garanta que o gabinete de controle tenha ventilação ativa. Evite colocar módulos que geram muito calor (como fontes de alimentação) diretamente abaixo do\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV142\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epara prevenir superaquecimento localizado.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegridade do Sinal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara minimizar interferência eletromagnética (EMI), roteie os cabos de entrada CA de alta tensão longe das linhas de sinal CC de baixa tensão. Use cabos blindados se o comprimento da fiação exceder 50 metros e conecte a blindagem à terra apenas na extremidade do gabinete.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeleção de Cabo:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePara conexões confiáveis de alta densidade, recomenda-se o uso do cabo dedicado Yokogawa AKB333. Este cabo é projetado especificamente para atender aos requisitos de isolamento para sinais de 220 V CA em 16 canais.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695399137643,"sku":"ADV142-P13 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-adv142-p13-s1-digital-input-module-fpjon21xc0c_5ca3c41b-3a84-4679-8c7c-b9a3406ee3a9.jpg?v=1766133606","url":"https:\/\/www.plcprotech.com\/pt\/products\/yokogawa-adv142-p13-s1-centum-vp-ac-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}