{"product_id":"yokogawa-stardom-fcn-rtu-nfar181-s00-s2-rtd-input-module","title":"Módulo de Entrada RTD Yokogawa STARDOM FCN-RTU NFAR181-S00 S2","description":"\u003ch3\u003eVisão Geral do Produto\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAR181-S00 S2 (NFAR181)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé um módulo de entrada RTD de alta densidade projetado para a série de controladores autônomos Yokogawa STARDOM FCN-RTU. Este módulo oferece 12 canais isolados para interface com diversos Detectores de Temperatura por Resistência (RTD), incluindo os tipos Pt100 e JPt100. Desenvolvido para monitoramento preciso de temperatura em processos industriais como controle de fornos, armazenamento criogênico e sistemas HVAC, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAR181\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egarante precisão do sinal dentro de\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e±0,03%\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eda escala completa. Cada canal é isolado individualmente para evitar propagação de ruído e interferência de loops de terra, o que é fundamental para manter dados de medição estáveis em ambientes com maquinário elétrico pesado. Ao integrar essas entradas de alto desempenho diretamente na arquitetura STARDOM, o módulo permite ciclos rápidos de atualização de dados e compensação de temperatura de alta confiabilidade, reduzindo significativamente o risco de desvios no processo e tempo de inatividade do sistema.\u003c\/p\u003e\n\u003ch3\u003eConfiguração Técnica\u003c\/h3\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAR181-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eé construído sobre uma plataforma de hardware robusta otimizada para estabilidade a longo prazo:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolamento de 12 Canais:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCada canal de entrada é eletricamente isolado tanto da lógica do sistema quanto dos canais adjacentes, apresentando uma tensão suportada de 1500 V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecisão de Medição:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO módulo utiliza uma corrente de medição de 1 mA para determinar a resistência, minimizando erros por autoaquecimento enquanto mantém uma alta relação sinal-ruído.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDetecção de Queima:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTodos os canais podem ser configurados para detecção de queima (UP\/DOWN) em até 60 segundos, fornecendo notificação imediata à lógica de controle em caso de falha do sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegridade dos Dados:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCom uma deriva máxima de temperatura de\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e±30\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eppm\/°C e ciclo de atualização de dados de 1 segundo, o módulo oferece medições consistentes e repetíveis mesmo sob condições ambientais variáveis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEspecificações Técnicas\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCaracterística\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEspecificação\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModelo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNFAR181-S00 S2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMarca\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapão\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCanais de Entrada\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12, isolados\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRTDs Suportados\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePt100 (3 fios), JPt100 (3 fios)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrecisão\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e±0,03%\u003c\/span\u003e da escala completa (0 a 400 Ohm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTensão Suportada\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC por 1 minuto\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensões\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32,8 x 130 x 107,5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeso\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0,2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConsumo de Energia\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA (5 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerguntas Técnicas Frequentes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuais padrões RTD são suportados pelo NFAR181?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO módulo suporta múltiplos padrões internacionais, incluindo JIS C 1604:1997\/1989 e IEC 60751:1995\/1986. Isso garante compatibilidade com sensores Pt100 e JPt100 modernos e legados.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQual é a resistência máxima permitida na fiação para cada canal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePara manter a precisão nominal, a resistência da fiação deve ser de 40 Ohm ou menos por fio. É fundamental que cada um dos três fios usados na configuração RTD de 3 fios tenha resistência igual para cancelar efetivamente os erros dos fios de conexão.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEste módulo pode ser usado em locais perigosos?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eO sufixo \"S00\" indica que esta é uma versão padrão sem proteção contra explosão. Para aplicações em áreas classificadas, ele deve ser instalado dentro de uma caixa à prova de explosão certificada ou usado em conjunto com barreiras de segurança intrínseca.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGuia de Engenharia e Instalação\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniformidade da Fiação:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse configurações RTD de 3 fios para compensar a resistência dos fios de conexão. Certifique-se de que os três fios tenham o mesmo comprimento e bitola. Resistências desiguais entre os fios de conexão resultarão em um deslocamento na medição que não pode ser corrigido pela lógica interna do módulo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAterramento e Blindagem:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse pares trançados e blindados para toda a fiação de campo RTD. A blindagem deve ser aterrada no lado do controlador em um terra dedicado para instrumentos. Evite passar esses cabos de sinal de baixo nível paralelamente a cabos de energia AC de alta corrente para prevenir acoplamento de ruído indutivo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsiderações Térmicas:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO módulo é classificado para operação até 70 °C. Ao montar em um nó STARDOM, certifique-se de que os terminais de pressão estejam firmemente apertados para minimizar a resistência de contato, que pode ser interpretada erroneamente como variações de temperatura.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstalação Mecânica:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs dimensões do módulo são 32,8 mm de largura por 130 mm de altura. Ao inserir o módulo na placa traseira FCN-RTU, confirme que o módulo está totalmente encaixado antes de apertar os parafusos de fixação a 0,5 Nm. Use os terminais de pressão fornecidos para conexões de campo seguras.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52695399399787,"sku":"NFAR181-S00 S2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/yokogawa-nfar181-s00-s2-rtd-input-module-0mjcd5si4ik_42e45bbf-3b50-480b-af6d-3bfd756cd1bd.jpg?v=1766133631","url":"https:\/\/www.plcprotech.com\/pt\/products\/yokogawa-stardom-fcn-rtu-nfar181-s00-s2-rtd-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}