{"product_id":"abb-07-di-92-gjr5-2524-00-r0101-digital-input-module","title":"ABB 07 DI 92 GJR5 2524 00 R0101 Digital input module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB 07 DI 92 GJR5 2524 00 R0101\u003c\/strong\u003e, also recognized under the engineering database entry \u003cstrong\u003e07DI92 GJR5252400R0101\u003c\/strong\u003e, is a high-density decentralized digital input module designed for the Advant Controller 31 (AC31) core automation platform. Functioning as a remote bus node on the standardized \u003cstrong\u003eCS31 system bus\u003c\/strong\u003e, this module facilitates localized binary telemetry collation from fields straight to the central processing architecture. This unit incorporates \u003cstrong\u003e32 digital input channels\u003c\/strong\u003e configured for 24 V DC monitoring loops. To maximize signal reliability against electromagnetic disruptions and ground tracing errors, the device relies on comprehensive galvanic optocoupler isolation between the binary sensor interface and the internal data backbone. Utilizing an EIA RS-485 link interface, it delivers stable state mapping, transient suppression, and high continuous uptime across chemical, manufacturing, and distribution installations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n  \u003cli\u003eIntegrates 32 binary inputs rated at a nominal processing voltage threshold of 24 V DC.\u003c\/li\u003e\n  \u003cli\u003eEstablishes secure multi-drop remote network routing using the verified EIA RS-485 CS31 system bus protocol.\u003c\/li\u003e\n  \u003cli\u003eMaintains safe electrical boundaries via internal optocoupler assemblies isolating processing CMOS lines from field-side transients.\u003c\/li\u003e\n  \u003cli\u003eProvides comprehensive diagnostics using a front-panel LED matrix dedicated to individual channel values and bus line tracking statuses.\u003c\/li\u003e\n  \u003cli\u003eSuppresses erratic mechanical contact bounce and line interference through internal hardware input delay filter configurations.\u003c\/li\u003e\n  \u003cli\u003eSimplifies configuration via a manual binary DIL switch array accessible beneath a lateral sliding protective door interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; padding-left: 20px;\"\u003e\n  \u003cli\u003eDistributed multi-point limit switch monitoring and digital telemetry aggregation within Advant Controller 31 automation networks.\u003c\/li\u003e\n  \u003cli\u003eHigh-density sensor signal marshaling inside centralized low-voltage switchgear enclosures and remote control desks.\u003c\/li\u003e\n  \u003cli\u003eContinuous packaging lines and material handling infrastructure demanding decentralized input mapping with minimal latency.\u003c\/li\u003e\n  \u003cli\u003eRemote auxiliary contact tracking for circuit breakers, isolation valves, and emergency shutdown safety interlocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d; font-weight: bold;\"\u003eModel\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d; font-weight: bold;\"\u003eOrder Number\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e07 DI 92 (07DI92) Digital Input Module\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eGJR5 2524 00 R0101 (GJR5252400R0101)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d; font-weight: bold;\"\u003eParameter Category\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d; font-weight: bold;\"\u003eTechnical Specifications\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e07 DI 92 \/ 07DI92\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eOrder Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eGJR5 2524 00 R0101 \/ GJR5252400R0101\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eProduct Function\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eDigital Input Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eSystem Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eAdvant Controller 31 (AC31 \/ 90 Series)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eNetwork Connection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eCS31 System Bus (EIA RS-485 Standard)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eTotal Input Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e32 Channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eNominal Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eOperational Temperature Envelope\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e0 to 55 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eStorage Temperature Bound\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e-25 to 75 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eGalvanic Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eIntegrated via optocouplers between data backbone and binary process line\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eLocal Status Monitoring\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eDirect LED panel array mapping channel values and communications diagnostics\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eMechanical Dimensions\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e120 mm Width x 140 mm Height x 85 mm Depth\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eNet Module Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e450 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e0.55 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; color: #2d3748;\"\u003e135 mm x 155 mm x 100 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 5px 0;\"\u003eCRITICAL WARNING: COMPLETE SYSTEM POWER DE-ENERGIZATION REQUIRED\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all 24 V DC instrumentation loops, auxiliary power supplies, and field signal power links before starting any module configuration, wire termination, or block changeout procedures. Operating or connecting data line plugs during live electrical status can initiate field line transients, generate false PLC execution faults, and cause severe, unrecoverable damage to localized internal CMOS processing chips.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eHook the upper attachment flange of the module over the top edge of a thoroughly grounded standard 35 mm top-hat DIN rail section, applying stable down-and-back physical force until the integrated structural spring clip seats firmly. Alternatively, use four M4 screws to fasten the rear housing plate flat onto a rigid layout subpanel.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eRetract the transparent protective dust plate cover located on the right vertical surface of the housing structure. Configure the physical binary switches to match the desired CS31 bus remote station destination index value before initializing loop power configurations.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 12px;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eLead the discrete multi-point 24 V DC field wires to the respective terminal pin configurations. Use high-integrity copper conductors, utilizing a maximum core sizing profile of 2.5 mm2 for power distribution runs and 1.5 mm2 for individual input processing lines.\u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003eTerminate the incoming and outgoing RS-485 serial fieldbus wires of the CS31 framework. Connect the structural cable foil shield material securely to a common earthing bar directly at the control cabinet layout threshold to ensure thorough electromagnetic shielding compliance.\u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668563390827,"sku":"07DI92 GJR5252400R0101","price":1200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-07di92-gjr5252400r0101-digital-i-o-module-kzmqmk5z13u_7efa68e6-f179-4118-99c4-160e27d53b82.jpg?v=1765532947","url":"https:\/\/www.plcprotech.com\/ru\/products\/abb-07-di-92-gjr5-2524-00-r0101-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}