{"product_id":"abb-icso-08-y1-fpr3311101r0026-advant-controller-31-digital-output-module","title":"ABB ICSO 08 Y1 FPR3311101R0026 Advant Controller 31 Digital Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB ICSO 08 Y1 FPR3311101R0026\u003c\/strong\u003e serves as a remote \u003cstrong\u003edigital output module\u003c\/strong\u003e designed for deployment on the \u003cstrong\u003eABB Procontic CS31\u003c\/strong\u003e system bus topology. This hardware component contains 8 electrically isolated output channels operating with solid-state transistors to execute precise control commands within automated process networks. Engineered to distribute discrete signals safely, the module integrates automated local diagnosis functions and maintains built-in protection parameters to monitor structural channel errors and avoid operational downtime.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTransistor-based output architecture providing reliable switching speeds across 8 independent channels.\u003c\/li\u003e\n\u003cli\u003eComplete electrical isolation built between the CS31 system bus interface and internal output electronics to isolate control loops.\u003c\/li\u003e\n\u003cli\u003eIntegrated short-circuit and overload protection configurations per channel ensuring robust field survival.\u003c\/li\u003e\n\u003cli\u003eFront panel diagnostic array featuring status indicators and a dedicated manual test switch for physical troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRemote output routing within standard Advant Controller 31 distributed architectures.\u003c\/li\u003e\n\u003cli\u003eSolenoid valve actuation and localized power relay distribution networks.\u003c\/li\u003e\n\u003cli\u003eDiscrete binary signal handling in centralized manufacturing and process environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModule \/ Accessory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug-in base ECZ\u003c\/td\u003e\n\u003ctd\u003eMechanical interface base\u003c\/td\u003e\n\u003ctd\u003eFPR3700001R0001 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule ICSO 08 Y1\u003c\/td\u003e\n\u003ctd\u003e24 V DC Version\u003c\/td\u003e\n\u003ctd\u003eFPR3311101R1022 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule ICSO 08 Y1\u003c\/td\u003e\n\u003ctd\u003e230 V AC Version\u003c\/td\u003e\n\u003ctd\u003eFPR3311101R0026 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003eFPR3311101R0026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd\u003eICSO 08 Y1 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8 (electrically isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Supply Voltage UP\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current per Output\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Current of 8 Outputs\u003c\/td\u003e\n\u003ctd\u003emax. 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.2 A (without output loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e6 VA (without output loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Leakage Current (Signal 0)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lamp Load\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency (Inductive Load)\u003c\/td\u003e\n\u003ctd\u003emax. 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Indication\u003c\/td\u003e\n\u003ctd\u003e1 yellow LED per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Label\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eBUS2\u003c\/td\u003e\n\u003ctd\u003eCS31 System Bus Connection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eBUS1\u003c\/td\u003e\n\u003ctd\u003eCS31 System Bus Connection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eShield\u003c\/td\u003e\n\u003ctd\u003eCS31 System Bus Shield \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eZP\u003c\/td\u003e\n\u003ctd\u003eReference Potential 0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8...15\u003c\/td\u003e\n\u003ctd\u003eA0...A7\u003c\/td\u003e\n\u003ctd\u003eAlternative Digital Output Terminals \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003eL1\u003c\/td\u003e\n\u003ctd\u003eMains Connection Line 1 (230 V AC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003eN\u003c\/td\u003e\n\u003ctd\u003eMains Connection Neutral \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003ePE\u003c\/td\u003e\n\u003ctd\u003eProtective Earth \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003eUP\u003c\/td\u003e\n\u003ctd\u003eProcess Voltage +24 V DC (Parallel Connection 1) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eUP\u003c\/td\u003e\n\u003ctd\u003eProcess Voltage +24 V DC (Parallel Connection 2) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e21...28\u003c\/td\u003e\n\u003ctd\u003eA0...A7\u003c\/td\u003e\n\u003ctd\u003eSecondary Digital Output Connections \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eZP\u003c\/td\u003e\n\u003ctd\u003eReference Potential 0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Mounting:\u003c\/strong\u003e The module must be securely mounted onto the plug-in base ECZ and fastened using the two integrated panel screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Coding:\u003c\/strong\u003e Set the mechanical coding ring on the ECZ plug-in base to match the correct supply voltage prior to plugging the module in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Voltage Sequencing:\u003c\/strong\u003e The external process voltage supply must be switched on before or simultaneously with the 230 V AC mains supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Power Infeed:\u003c\/strong\u003e Connect the process voltage in parallel across both terminal 19 and terminal 20 to handle the aggregate output load capacity up to 8 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Loading:\u003c\/strong\u003e Ensure each active channel supports a minimum current load of at least 50 mA to prevent leakage paths from disrupting the safe OFF state.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668613427563,"sku":"ICSO08Y1 FPR3311101R0026","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-icso08y1-binary-output-unit-5dieydoamzh_0ab48b4d-a1cb-48de-b0b1-b8c216fde572.jpg?v=1765535576","url":"https:\/\/www.plcprotech.com\/ru\/products\/abb-icso-08-y1-fpr3311101r0026-advant-controller-31-digital-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}