{"product_id":"abb-pm865k01-3bse031151r1-ac-800m-high-integrity-processor-unit","title":"ABB PM865K01 3BSE031151R1 AC 800M High Integrity Processor Unit","description":"\u003cp\u003eThe \u003cstrong\u003eABB PM865K01 (Product ID: 3BSE031151R1)\u003c\/strong\u003e is a high-integrity central processing unit package engineered for the \u003cstrong\u003eAC 800M\u003c\/strong\u003e hardware platform. It is certified for use in safety-critical applications up to \u003cstrong\u003eSafety Integrity Level 3 (SIL3)\u003c\/strong\u003e in accordance with IEC 61508. Operating at 96MHz with 32MB of onboard memory, this processor unit serves as a highly robust control solution capable of running both non-SIL and SIL-classified applications simultaneously when deployed within an \u003cstrong\u003eAC 800M High Integrity\u003c\/strong\u003e controller configuration.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM865K01\u003c\/strong\u003e provides advanced internal diagnostics, enhanced oscillator supervision, and integrated double over-voltage protection on internal voltages. To comply with strict international safety standards, the module utilizes a dedicated monitoring architecture that requires configuration according to the official ABB Safety Manual. It facilitates expansive industrial connectivity through its built-in electrical and optical ModuleBus interfaces, alongside dual RJ45 Ethernet ports for highly available control network communications.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Integrity Level Certification:\u003c\/strong\u003e Fully qualified for SIL3 safety-critical installations when configured with an SM811 safety module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Architecture:\u003c\/strong\u003e Equipped with a 96MHz microprocessor and 32MB of robust system and user RAM.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Built-in hardware-driven double inverted memory handling for real-time bit error detection without cycle delay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Integrates double over-voltage protection on internal supply lines and enhanced system watchdog timers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Communication Expansion:\u003c\/strong\u003e Built-in CEX-Bus interface allows for step-by-step expansion using various fieldbus protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBumpless Redundancy:\u003c\/strong\u003e Supports hot stand-by processor redundancy via an RCU Link, enabling fault changeover in less than 10 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Mechanics:\u003c\/strong\u003e Features a slide-and-lock mechanism for secure DIN-rail installation and direct chassis grounding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Instrumented Systems (SIS):\u003c\/strong\u003e Emergency Shutdown (ESD) and fire and gas protection systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed Control Systems (DCS):\u003c\/strong\u003e Continuous process control loop operations across large-scale industrial plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Integrity Automation:\u003c\/strong\u003e Critical infrastructure management requiring simultaneous execution of control and safety functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoiler and Burner Management Systems (BMS):\u003c\/strong\u003e Safe sequencing and combustion monitoring for heavy utility boilers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM865K01\u003c\/strong\u003e product package includes the following verified hardware components:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eItem \/ Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePM865\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE031151R1\u003c\/td\u003e\n\u003ctd\u003eSafety CPU, 96MHz, 32MB (No license included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTP830\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eBaseplate Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB850\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eCEX-bus Terminator (Male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB807\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eModuleBus Terminator Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTB852\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eRCU-Link Terminator Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4943013-6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eLithium battery for memory backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE031151R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eABB Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM865K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePortable Lithium (9 g weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 degC (ambient outside enclosure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot RoHS 2 2011\/65\/EU compliant (Spare part rules apply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ch4\u003eCN1 and CN2 Control Network Ports\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTD+\u003c\/td\u003e\n\u003ctd\u003eTransmit Data (plus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTD-\u003c\/td\u003e\n\u003ctd\u003eTransmit Data (minus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD+\u003c\/td\u003e\n\u003ctd\u003eReceive Data (plus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4-5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot used\u003c\/td\u003e\n\u003ctd\u003eLeave disconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD-\u003c\/td\u003e\n\u003ctd\u003eReceive Data (minus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7-8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot used\u003c\/td\u003e\n\u003ctd\u003eLeave disconnected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShield\u003c\/td\u003e\n\u003ctd\u003eChassis ground connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eCOM3 Serial Port (RS-232C with Modem Control)\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTS\u003c\/td\u003e\n\u003ctd\u003eRequest To Send\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDTR\u003c\/td\u003e\n\u003ctd\u003eData Terminal Ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTD\u003c\/td\u003e\n\u003ctd\u003eTransmit Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0V\u003c\/td\u003e\n\u003ctd\u003eSignal ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0V\u003c\/td\u003e\n\u003ctd\u003eSignal ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRD\u003c\/td\u003e\n\u003ctd\u003eReceive Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDCD\u003c\/td\u003e\n\u003ctd\u003eData Carrier Detect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCTS\u003c\/td\u003e\n\u003ctd\u003eClear To Send\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShield\u003c\/td\u003e\n\u003ctd\u003eChassis ground connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting:\u003c\/strong\u003e Install horizontally onto a top-hat type TS 35\/7.5 DIN-rail. Rotate the baseplate locking device counter-clockwise to the OPEN position before clipping onto the rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlide \u0026amp; Interconnect:\u003c\/strong\u003e Once hooked over the upper edge of the rail, move the locking device to the SLIDE position. Slide the module sideways to align carefully and mate its baseplate connectors with adjacent units. Ensure strict pin alignment to prevent physical structural damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Lock the unit into place by turning the locking screw clockwise to the LOCKED position. This engages the internal grounding mechanism firmly against the unpainted metal surface of the DIN-rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Wiring:\u003c\/strong\u003e Connect the 24V DC lines into the screw terminals of the baseplate. To suppress unexpected errors from monitoring links when a single supply is utilized, jump input terminals SA and SB on the unit directly to +24 V DC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Handling:\u003c\/strong\u003e Do not plug the internal lithium battery into its respective slot until the controller has fully powered up normally and the active battery LED begins to flash. Inserting the battery into a powered-down module will instantly exhaust its cell power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668530819435,"sku":"PM865K01 3BSE031151R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-pm865k01-3bse031151r1-processor-unit-w4mdhcsxlpe_fd095906-f6ab-472c-aa42-0920fc1e14db.jpg?v=1765532903","url":"https:\/\/www.plcprotech.com\/ru\/products\/abb-pm865k01-3bse031151r1-ac-800m-high-integrity-processor-unit","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}