{"product_id":"abb-rtac-01-3abd64610805-pulse-encoder-interface-module-1","title":"ABB RTAC-01 3ABD64610805 Pulse Encoder Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRTAC-01\u003c\/strong\u003e (Product ID \u003cstrong\u003e3ABD64610805\u003c\/strong\u003e) is a hardware component designed to interface digital pulse encoders with host variable speed drive systems. This \u003cstrong\u003ePulse Encoder Interface Module\u003c\/strong\u003e functions as an extension option that transfers precise rotational feedback data—such as position and speed vectors—directly to the core drive control processor. By converting physical quadrature and differential pulse sequences into standardized electrical feedback profiles, the board enables closed-loop speed regulation and micro-step torque modulation. The pluggable assembly is built to mount into option slots of industrial converters, making it compatible with legacy and modern drive configurations such as the ACS600 options platform. It provides high-frequency optical isolation barriers to protect delicate processing ICs from voltage induction spikes commonly present across encoder cabling runs.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop Speed Feedback:\u003c\/strong\u003e Translates dual-channel incremental pulse tracks to allow exact velocity control inside multi-range drives.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Option Frame Support:\u003c\/strong\u003e Specifically tailored to match the physical dimension profiles of the ACS600 option system frame slots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular Screw-Terminal Matrix:\u003c\/strong\u003e Equipped with prominent dual-tier removable connector blocks for reliable field signal attachment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Galvanic Isolation:\u003c\/strong\u003e Mitigates common-mode electrical noise and high-frequency grounding loop currents originating from remote motor encoders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClosed-Loop Velocity and Position Tracking in ACS600 Option Drive Environments\u003c\/li\u003e\n\u003cli\u003eDirect Rotary Pulse Encoder Feedback Processing for Process Line Conveyors\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Speed Feedback Interfacing in Material Handling Automation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eMechanical\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTAC-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3ABD64610805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eACS600_option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Depth \/ Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85049099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWEEE Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct Not in WEEE Scope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe interface layout includes dedicated multi-position plug-in screw terminals:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal \/ Connector Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eInterface Function\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block X1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrimary lower connection sequence for encoder power supply routing and diagnostic signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Block X2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpper processing connection interface for pulse track inputs (e.g., A, B, and Z channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Prevention Measures:\u003c\/strong\u003e Ensure a grounded wrist strap is worn during unpacking and slot insertion to shield internal logic tracks from static discharge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption Card Mechanical Placement:\u003c\/strong\u003e Slide the card firmly into the host drive's option slot guide tracks, confirming the rear pins are fully mated before securing mounting screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding Management:\u003c\/strong\u003e Terminate encoder signal cable shields at the designated ground clamps on the drive chassis to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Verification:\u003c\/strong\u003e Check that the modular orange terminal blocks X1 and X2 are fully pressed down into their sockets to ensure continuous signal continuity under vibrational stress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52668525412715,"sku":"RTAC-01 3ABD64610805","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/abb-rtac-01-64610805-pulse-encoder-interface-module-2ganjysi3ic_b16e8eea-e692-405e-9963-ff2684e55742.jpg?v=1765532776","url":"https:\/\/www.plcprotech.com\/ru\/products\/abb-rtac-01-3abd64610805-pulse-encoder-interface-module-1","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}