{"product_id":"abb-stromberg-di86-32-digital-input-module","title":"ABB Stromberg DI86-32 Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748;\"\u003eThe ABB Stromberg DI86-32 is a high-density digital input board engineered for discrete signal acquisition within legacy Stromberg industrial automation systems. Operating as a critical field interface, this module samples binary status inputs from remote contacts, limit switches, and proximity sensors across \u003cstrong\u003e32 distinct channels\u003c\/strong\u003e, converting field-side voltage levels into logic-level data for processing by the central processing architecture. To ensure robust performance in electrically noisy environments, the board utilizes hardware filtering and optical isolation components, effectively shielding sensitive processor logic from ground loops, high-voltage transients, and inductive switching noise.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Density Architecture:\u003c\/strong\u003e Manages 32 digital input channels on a single module to optimize subrack space utilization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNative Bus Synchronization:\u003c\/strong\u003e Designed for direct installation and immediate hardware timing alignment on Stromberg system backplanes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Circuit Isolation:\u003c\/strong\u003e Implements onboard isolation barriers to prevent field-side faults from propagating to core logic segments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTrace Integrity Protection:\u003c\/strong\u003e Manufactured with rigid structural reinforcement to resist trace separation and cracking under continuous mechanical stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px;\"\u003e\n  \u003cli\u003eDiscrete signal monitoring and status acquisition within legacy Stromberg control panels.\u003c\/li\u003e\n  \u003cli\u003eInterfacing field contacts in metal processing facilities, power distribution plants, and paper manufacturing mills.\u003c\/li\u003e\n  \u003cli\u003eMaintenance support and component replacement in obsolete control racks to prevent unexpected process downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eABB\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSeries Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStromberg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDI86-32\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eComponent Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eDigital Input Board\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eNumber of Input Channels\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e32\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Lifecycle Status\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eObsolete\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExport Control Regulations (ECCN)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCommodity Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85389091\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProduct Net Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.40 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0.75 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e25 x 279 x 203 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eSweden (SE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 12px; margin-bottom: 15px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 4px 0 0 0;\"\u003eDe-energize the main rack assembly and disconnect all field-side sensing voltages linked to the input terminal blocks prior to swapping modules. Live insertion or extraction of input assemblies risks triggering unexpected output actions, severe backplane arcing, or catastrophic failure of processing components. Check all associated terminal rows with a calibrated tester to confirm zero-energy status before touch.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eFasten an approved electrostatic discharge wrist strap to your forearm and link the ground lead directly to the unpainted steel panel framework.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eLoosen the front-panel terminal block screws or disconnect the dedicated field wiring harnesses from the face of the faulty module, marking all terminal pairs for exact re-mapping.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eRelease the top and bottom retention fasteners on the module frame, pull the extraction levers, and slide the card steadily out of the backplane guide rails.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 10px;\"\u003e\n  \u003cdiv style=\"display: inline-block; background-color: #2b6cb0; color: #ffffff; width: 24px; height: 24px; border-radius: 50%; text-align: center; font-weight: bold; margin-right: 8px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"display: inline-block; color: #2d3748;\"\u003eAlign the new board within the subrack tracking grooves, press firmly until the rear pin configurations lock into the backplane, tighten all retention screws, and re-terminate the field inputs.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52701956342123,"sku":"DI86-32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/di86-32-gfusa0o3mwg_e2d631de-fbe9-4a23-9c46-ca84fe8d55fb.jpg?v=1766478087","url":"https:\/\/www.plcprotech.com\/ru\/products\/abb-stromberg-di86-32-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}