{"product_id":"allen-bradley-pm3398b-6-1-3-e-80026-172-24-powerfactors-ac-dc-power-supply","title":"Allen-Bradley PM3398B-6-1-3-E 80026-172-24 PowerFactors AC-DC Power Supply","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePM3398B-6-1-3-E (Part Number: 80026-172-24)\u003c\/strong\u003e is a single-phase PFC isolated front-end AC-to-DC power supply designed for industrial control and automation applications. This unit provides a regulated 56 VDC output with power factor correction and integrated protection functions for reliable operation in commercial and industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley PM3398B-6-1-3-E\u003c\/strong\u003e delivers up to 1500 W output power and supports remote sensing, voltage adjustment, overcurrent protection, overvoltage protection, and overtemperature protection. The isolated output architecture allows reference flexibility while maintaining electrical separation between input and output circuits.\u003c\/p\u003e\n\u003cp\u003eDesigned for panel-mounted installations, the power supply incorporates forced-air cooling and is suitable for automation systems requiring stable DC power for controllers, drives, I\/O systems, communication equipment, and associated industrial electronics.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle-phase PFC isolated front-end power supply\u003c\/li\u003e\n\u003cli\u003e1500 W output rating\u003c\/li\u003e\n\u003cli\u003e56 VDC nominal output\u003c\/li\u003e\n\u003cli\u003e26.8 A output current\u003c\/li\u003e\n\u003cli\u003ePower factor corrected input\u003c\/li\u003e\n\u003cli\u003eUniversal 90 to 264 VAC input range\u003c\/li\u003e\n\u003cli\u003eRemote sense capability\u003c\/li\u003e\n\u003cli\u003eOutput voltage adjustment\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection\u003c\/li\u003e\n\u003cli\u003eSelf-contained forced-air cooling\u003c\/li\u003e\n\u003cli\u003eIsolated output design\u003c\/li\u003e\n\u003cli\u003ePower fail signal option\u003c\/li\u003e\n\u003cli\u003eCurrent limit protection option\u003c\/li\u003e\n\u003cli\u003eBuilt-in internal fuse option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePLC and DCS control systems\u003c\/li\u003e\n\u003cli\u003eIndustrial automation panels\u003c\/li\u003e\n\u003cli\u003eProcess control equipment\u003c\/li\u003e\n\u003cli\u003eMotion control systems\u003c\/li\u003e\n\u003cli\u003eCommunication cabinets\u003c\/li\u003e\n\u003cli\u003eFactory automation systems\u003c\/li\u003e\n\u003cli\u003eTest and measurement equipment\u003c\/li\u003e\n\u003cli\u003ePower distribution assemblies\u003c\/li\u003e\n\u003cli\u003eOEM machine control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003ePart Number\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePM3398B-6-1-3-E\u003c\/td\u003e\n\u003ctd\u003e80026-172-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eGeneral\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOriginal Manufacturer\u003c\/td\u003e\n\u003ctd\u003ePioneer Magnetics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePM3398B-6-1-3-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC-DC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e1500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e11 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5 x 5 x 11.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Specifications\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e90 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Phase\u003c\/td\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e0.99 at Full Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Current\u003c\/td\u003e\n\u003ctd\u003eMeets IEC 555-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-Up Time\u003c\/td\u003e\n\u003ctd\u003e30 ms from AC input loss to output reduction from 42 V at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Specifications\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e56 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e26.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Adjustment Range\u003c\/td\u003e\n\u003ctd\u003e+5% to -10% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e1500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOutput isolated and may be referenced positive or negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Regulation\u003c\/td\u003e\n\u003ctd\u003eLine: +\/-0.1%; Load: +\/-0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Stability\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% for 24 hours after 30 minute warm-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Sense Compensation\u003c\/td\u003e\n\u003ctd\u003eUp to 0.5 V total loop drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple and Noise\u003c\/td\u003e\n\u003ctd\u003e1% maximum bandwidth limited to 20 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On Delay\u003c\/td\u003e\n\u003ctd\u003e1 second maximum after AC application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-Off Delay\u003c\/td\u003e\n\u003ctd\u003eGreater than or equal to 180 VAC operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e62.5 V +\/-1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercurrent Protection\u003c\/td\u003e\n\u003ctd\u003eCurrent limit option available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertemperature Protection\u003c\/td\u003e\n\u003ctd\u003eAutomatic shutdown and restart after cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Fail Signal\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Detect\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironmental Specifications\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +50 degC at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Derating\u003c\/td\u003e\n\u003ctd\u003e2.5% per degC above +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 8000 ft, derated 75 W per 1000 ft above 4000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e0.02 in double amplitude, 5 to 27 Hz; 0.10 in double amplitude, 17 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e5 G half sine, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCompliance\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eDesigned to meet UL1950, CSA22.2 No.950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eDesigned to meet FCC Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity\u003c\/td\u003e\n\u003ctd\u003eDesigned to meet EN50082 Level A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Standard\u003c\/td\u003e\n\u003ctd\u003eDesigned to meet EN60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Terminal\u003c\/td\u003e\n\u003ctd\u003eSingle-phase AC input (90 to 264 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Terminal\u003c\/td\u003e\n\u003ctd\u003e56 VDC regulated output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Sense +\u003c\/td\u003e\n\u003ctd\u003ePositive remote voltage sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Sense -\u003c\/td\u003e\n\u003ctd\u003eNegative remote voltage sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Fail Signal\u003c\/td\u003e\n\u003ctd\u003eOptional open collector status output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUndervoltage Detect\u003c\/td\u003e\n\u003ctd\u003eOptional status output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDB25 Connector\u003c\/td\u003e\n\u003ctd\u003eOptional signal interface connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the unit inside a commercial or industrial control enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain ambient temperature below 50 degC and relative humidity below 95%.\u003c\/li\u003e\n\u003cli\u003eDo not obstruct airflow from the internal cooling fan.\u003c\/li\u003e\n\u003cli\u003eUse mounting hardware that does not exceed 3\/32 in penetration depth.\u003c\/li\u003e\n\u003cli\u003eVerify all input and output wiring before applying AC power.\u003c\/li\u003e\n\u003cli\u003eConnect suitable gauge conductors to input and output terminals.\u003c\/li\u003e\n\u003cli\u003eUse remote sense terminals when voltage compensation is required at the load.\u003c\/li\u003e\n\u003cli\u003eConfirm output voltage with a digital voltmeter before connecting critical loads.\u003c\/li\u003e\n\u003cli\u003eProvide adequate enclosure ventilation to support forced-air cooling.\u003c\/li\u003e\n\u003cli\u003eObserve polarity when connecting DC output wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL1950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA22.2 No.950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFCC Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN50082 Level A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN60950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52695190012267,"sku":"PM3398B-6-1-3-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/allen-bradley-pm3398b-6-1-3-e-power-supply-nmxhkelbxjk_89a02f9a-8ffe-4379-95df-45c157277cad.jpg?v=1766114596","url":"https:\/\/www.plcprotech.com\/ru\/products\/allen-bradley-pm3398b-6-1-3-e-80026-172-24-powerfactors-ac-dc-power-supply","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}