{"product_id":"beckhoff-cp6601-0021-0020-cp6601-series-panel-pc","title":"Beckhoff CP6601-0021-0020 CP6601 Series Panel PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eFulfilling the demand for space-saving control interfaces, the Beckhoff CP6601-0021-0020 built-in Panel PC combines an industrial-grade touch display with a reliable ARM Cortex-A8 processor to execute precise control and visualization tasks directly at the machine level. This hardware integration functions as an optimized control node, utilizing its 1 GHz processing core and \u003cstrong\u003eWindows Embedded Compact 7\u003c\/strong\u003e environment to run TwinCAT-based PLC automation projects with low power consumption. The mechanical design incorporates a robust aluminum front frame with a sheet-steel rear cover, engineered specifically for flush installation within control cabinets or console enclosures.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEfficient ARM Processing:\u003c\/strong\u003e Equipped with an ARM Cortex-A8 processor running at 1 GHz for deterministic control and real-time visualization.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Memory Architecture:\u003c\/strong\u003e Features 1 GB DDR3 RAM paired with onboard NOVRAM for secure system variables and volatile parameter buffering.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual Network Interfaces:\u003c\/strong\u003e Built-in independent ports for standard 10\/100BASE-T Ethernet and high-speed EtherCAT fieldbus networking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated MicroSD Storage:\u003c\/strong\u003e Includes a dedicated slot supporting microSD cards up to 16 GB for system software, boot projects, and user configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHardware-Level UPS:\u003c\/strong\u003e Outfitted with an integrated 1-second capacitive uninterruptible power supply (UPS) to safely back up persistent data to NOVRAM during sudden power loss.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Environmental Protection:\u003c\/strong\u003e IP65 front-panel rating ensures resistance to dust, moisture, and water spray under operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eMachine-level Human-Machine Interface (HMI) for specialized manufacturing cells.\u003c\/li\u003e\n  \u003cli\u003eCompact controller and visualization nodes within packaging, material handling, and assembly systems.\u003c\/li\u003e\n  \u003cli\u003eDecentralized data acquisition and protocol gateway stations linking field devices to higher-level networks.\u003c\/li\u003e\n  \u003cli\u003eSub-system controls requiring direct EtherCAT master capabilities inside space-restricted control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eValue \/ Rating\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCP6601-0021-0020\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProcessor\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eARM Cortex-A8, 1 GHz\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMotherboard\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3.5-inch compact motherboard\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSystem Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 GB DDR3 RAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePersistent Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e128 kByte NOVRAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Slot\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x microSD slot (512 MB standard, expandable up to 16 GB)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating System\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eWindows Embedded Compact 7 (English)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eTwinCAT Performance Level\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTwinCAT 2: PLC level 30 \/ TwinCAT 3: PLC level 30\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSupply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eUPS Architecture\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIntegrated 1-second capacitive UPS\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eDisplay and Touch\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5.7-inch (640 x 480) with single-finger analog resistive touch screen\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAluminum front frame with sheet-steel rear protective cover\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eFront side IP65, rear side IP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e5.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003ePort \/ Interface Label\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eConnector Type\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eLAN (X101)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x 10\/100BASE-T Ethernet port for network integration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eEtherCAT (X102)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRJ45\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eReal-time on-board EtherCAT master interface\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eUSB 1 \u0026amp; USB 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSB Typ-A\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2 x USB 2.0 host interfaces for external input and updates\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCOM1 (X105)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eD-sub 9-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x RS232 serial interface for peripheral device communication\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3-pin terminal block\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC main power connection and UPS ground reference\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CP6601-0021-0020 serves as an optimized, embedded replacement for older ARM9-based control panels. When migrating from legacy displays running Windows CE 6 to Windows Embedded Compact 7 on this device, ensure your TwinCAT boot project target platform is updated to ARMv7. The compiled binaries for older ARM9 architectures must be rebuilt in TwinCAT 2\/3 to prevent runtime instruction-set mismatch faults during startup.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe integrated 1-second capacitive UPS is designed exclusively to back up critical variables in the 128 kByte NOVRAM during an unexpected power disruption. This UPS does not support runtime buffering of the entire Windows system image; it is highly critical that cyclic file-writing operations directly to the microSD card are structured carefully. Excessive continuous writes can lead to premature wear of the microSD sectors, which can corrupt the operating system partition during system restarts.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo protect the resistive touchscreen from static-induced register shifts, ensure the front bezel makes solid electrical contact with the cabinet metalwork, and that the cabinet is tied to a low-impedance ground. Use shielded CAT5e or CAT6 cabling for both the RJ45 Ethernet and EtherCAT connections. Route communication cables separately from high-current motor cables and variable frequency drives to suppress electromagnetic interference (EMI).\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to attempting any mechanical installation or wiring of this device, isolate all 24 V DC power sources. Verify that all auxiliary components and adjacent equipment are completely de-energized. Do not mount the unit in environments exceeding the rated operating limit of 55 degC, and maintain sufficient clearance behind the rear steel cover to allow passive convection cooling.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.25rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003ePrepare Panel Cutout:\u003c\/strong\u003e Prepare the installation cutout matching the standard dimensions for the 5.7-inch housing. Smooth and deburr all sharp sheet metal edges to prevent damage to the integrated front seal gasket.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.25rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eMount with Clamping Levers:\u003c\/strong\u003e Insert the Panel PC into the cutout from the front. Secure the unit using the built-in pull-out mechanical clamping levers accessible from the rear side. Tighten uniform pressure to compress the front gasket for IP65 dust and moisture protection.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.25rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eAttach Ground and Control Wiring:\u003c\/strong\u003e Connect the functional grounding wire from the panel frame directly to the central grounding rail. Plug the 24 V DC power supply lines into the provided 3-pin terminal block matching designated polarities.\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1.25rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; margin-right: 0.75rem; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003e\n    \u003cstrong\u003eEstablish Network Links:\u003c\/strong\u003e Insert the dedicated EtherCAT line into port X102 and the standard TCP\/IP networking line into port X101. Run the system and observe the diagnostic LEDs to confirm proper physical link activity.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106451186027,"sku":"CP6601-0021-0020","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cp6601-0021-0020-gtpe5u50yuf.png?v=1776243911","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-cp6601-0021-0020-cp6601-series-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}