{"product_id":"beckhoff-cpx2715-0010-cpx-series-15-inch-fanless-multi-touch-panel-pc","title":"Beckhoff CPX2715-0010 CPX Series 15-inch Fanless Multi-Touch Panel PC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned specifically for direct integration in hazardous environments, the \u003cstrong\u003eBeckhoff CPX2715-0010\u003c\/strong\u003e provides robust human-machine interface (HMI) performance within Zone 2 and Zone 22 classified areas. Utilizing a fanless cooling topology and a highly durable aluminum housing with an impact-resistant glass front, this built-in Panel PC combines physical resilience with high-performance computing capabilities. The integrated multi-touch capacitive screen supports precise multi-finger operation, making it suitable for modern industrial SCADA, visualization, and PLC control applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eRobust aluminum housing with a high-durability glass front, optimized for hazardous Zone 2 and 22 classifications.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eVibration-resistant pull-out clamping levers for rapid mounting without loose installation accessories.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eFanless thermal design utilizing heat-dissipating rear cooling fins to eliminate internal dust circulation.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHighly responsive capacitive multi-touch interface with high-resolution 15-inch visual display.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eDual high-speed on-board Ethernet interfaces plus expansion options for modular network architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHazardous explosive gas atmospheres classified under ATEX Zone 2 \/ IECEx Zone 2.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCombustible particulate environments classified under ATEX Zone 22 \/ IECEx Zone 22.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eOil and gas refining, chemical manufacturing, and batching plant operator terminals.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003ePharmaceutical processing plants requiring high-ingress front seals and chemical resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCPX2715-0010\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDisplay Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e15-inch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDisplay Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1024 x 768 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProcessor Platform\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIntel Atom E38xx Series (Single-core E3815 1.46 GHz up to Quad-core E3845 1.91 GHz)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eMemory Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 GB to 8 GB DDR3L RAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eStorage Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x CFast slot, 1 x 2.5-inch HDD\/SSD slot (up to 320 GB CFast)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eEthernet Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2 x 100\/1000BASE-T on-board (option for 1 additional port)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePeripheral Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 x USB 2.0, 1 x DVI\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInput Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eIngress Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eFront: IP65, Rear: IP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eATEX\/IECEx Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eII 3G Ex ec IIC T4 Gc \/ II 3D Ex tc IIIC T135 degC Dc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ecFMus Classification\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eClass I, II, III, Div 2, Groups A, B, C, D, F, G \/ Class I Zone 2 AEx ec IIC T4 Gc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e9.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTerminal \/ Interface\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 10px; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003e24 V DC Power Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePower supply connector (+24V, 0V, Functional Earth ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eEthernet (LAN 1 \/ LAN 2)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRJ45 interface for industrial control networks and TwinCAT communication\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eUSB 1 - USB 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUSB 2.0 host interfaces for local mouse, keyboard, or system recovery tasks\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eDVI Out\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eExternal digital display interface for secondary visualization channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CPX2715-0010 replaces standard, non-classified panel mounts in explosive risk areas. Note that because of the specialized hazardous area protection front, the cutout dimensions match standard CP2715 dimensions, but the mounting clamp pressure specs are significantly stricter to maintain the required Ex tc rating.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eSince the chassis is fanless, thermal dissipation is heavily dependent on free air convection across the rear cooling fins. Standard installations must preserve at least 50mm of clearance space above and below the rear panel. Operating continuously in unventilated enclosures above 45 degC ambient without checking thermal accumulation can lead to CPU throttling and performance level degradation under TwinCAT 3 runtimes.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo prevent electrostatic discharge hazards in hazardous dust environments (Zone 22), the ground connection terminal on the 24V supply connector must be bonded directly to the low-impedance machine reference ground using at least a 4mm squared earthing conductor. Do not use standard painted metallic panels as the sole source of structural grounding.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING:\u003c\/p\u003e\n  \u003cp style=\"margin: 5px 0 0 0; color: #2d3748;\"\u003eEnsure all electrical power is disconnected before installing, modifying, or cleaning the Panel PC. In hazardous locations, confirm that the local atmosphere is thoroughly purged and declared safe (non-hazardous) before opening the panel or connecting diagnostic equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eInsert the Panel PC into the pre-cut panel window from the front side, ensuring the sealing gasket is correctly seated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSecure the unit from the rear using the integrated pull-out clamping levers. Tighten the levers evenly to secure a solid seal against the mounting surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eConnect the low-impedance functional grounding line to the dedicated grounding screw on the housing chassis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"margin: 0; color: #2d3748;\"\u003eVerify correct insertion of your CFast flash or secondary 2.5-inch SSD drive, then wire the 24V DC input supply terminal connector.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106396660075,"sku":"CPX2715-0010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cpx2715-0010-l2jv50vmzo4.png?v=1776244093","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-cpx2715-0010-cpx-series-15-inch-fanless-multi-touch-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}