{"product_id":"beckhoff-cpx3719-0010-cpx-series-multi-touch-panel-pc","title":"Beckhoff CPX3719-0010 CPX Series Multi-touch Panel PC","description":"\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to withstand the rigorous demands of hazardous industrial locations, the **Beckhoff CPX3719-0010** combines a high-performance 19-inch multi-touch control interface with a fanless, robust computing architecture. This industrial panel PC is engineered specifically for mounting arm installation, providing a reliable operator interface directly at the machine or process site without requiring a separate control cabinet enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certification:\u003c\/strong\u003e Fully certified for ATEX, IECEx, and cFMus Zone 2\/22 environments, ensuring safe operation in the presence of flammable gases, vapors, or combustible dust.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Resolution Display:\u003c\/strong\u003e Features a 19-inch TFT display with a 1280 x 1024 resolution and capacitive multi-finger touch technology for precise operator inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Construction:\u003c\/strong\u003e Built with an IP65-rated aluminum housing and a heavy-duty glass front, protecting internal electronics from dust, water jets, and mechanical impacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFanless Thermal Management:\u003c\/strong\u003e Employs a passive cooling design that eliminates moving parts, reducing maintenance requirements and preventing dust ingress.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Storage \u0026amp; Memory:\u003c\/strong\u003e Equipped with dedicated slots for CFast and 2.5-inch SSD\/HDD storage, paired with high-reliability DDR3L RAM.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOil and Gas Processing:\u003c\/strong\u003e Safe deployment in upstream, midstream, and downstream monitoring stations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChemical and Petrochemical Plants:\u003c\/strong\u003e Reliable process visualization in areas with volatile organic compounds.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePharmaceutical Manufacturing:\u003c\/strong\u003e Cleanroom-compatible glass front design suitable for washdown environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrain and Powder Handling:\u003c\/strong\u003e Dust-ignition-proof protection for milling, packaging, and bulk material handling systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff Automation GmbH \u0026amp; Co. KG\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCPX3719-0010\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eDisplay Size \/ Resolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e19-inch TFT \/ 1280 x 1024 pixels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTouch Screen Technology\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eMulti-finger capacitive touch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProcessor Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIntel Atom E3815 (1.46 GHz, 1 Core) up to E3845 (1.91 GHz, 4 Cores)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eSystem Memory\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 GB to 8 GB DDR3L RAM\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Slots\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x CFast slot, 1 x 2.5-inch HDD\/SSD slot\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOn-Board Ethernet\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 x 100\/1000BASE-T (one led out, one additional optional)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eExternal Interfaces\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x RJ45 Push-Pull Ethernet, 2 x USB 2.0 (with IP65 protective cover)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCooling Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePassive (fanless)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP65 (fully enclosed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to 45 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eATEX Certification\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eII 3 G Ex nA IIC T5 Gc, II 3 D Ex tc IIIC T100 degC Dc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eIECEx Certification\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eEx nA IIC T5 Gc, Ex tc IIIC T100 degC Dc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ecFMus Certification\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eClass I, II, III, Div 2, Groups A-G; Class I, Zone 2, AEx ec IIC T5 Gc; Zone 22, AEx tc IIIB T100 degC Dc\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eTwinCAT Compatibility\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eTwinCAT 2 (Performance Level 40\/50), TwinCAT 3 (Performance Level 40\/50)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e10.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e530 x 460 x 160 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eConnector \/ Interface\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; font-weight: bold;\"\u003eFunction \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEthernet Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x RJ45 Push-Pull connector (100\/1000BASE-T) for network integration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eUSB Ports\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2 x USB-A 2.0 ports protected by a screw-on IP65 cover plate\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3-pin terminal block for 24 V DC power supply (V+, V-, PE)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eMounting Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4 x M6 threaded holes spaced at 100 x 100 mm on the connection block\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe CPX3719-0010 is a direct, hazardous-area-certified alternative to standard CP3719 series panels. When replacing older CP77xx or CP79xx series units, verify the mounting arm adapter spacing, as legacy units may require an adapter plate. Additionally, ensure your TwinCAT runtime license matches the target processor performance class (Performance Level 40 for single-core E3815, or Level 50 for quad-core E3845) to avoid licensing mismatches during deployment.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this unit relies entirely on passive convection cooling, thermal performance is highly dependent on mounting orientation. Mounting the panel with an upward or downward tilt exceeding 45 degrees from vertical can restrict airflow across the rear cooling fins, potentially leading to thermal throttling when operating near the 45 degC ambient limit. Avoid installing the unit in direct sunlight to prevent solar loading from exceeding the maximum rated operating temperature.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo maintain the IP65 environmental rating, the USB protective cover must be fully tightened with its integrated gasket intact when external USB devices are not connected. Always use high-quality, shielded Cat6 Ethernet cabling with industrial push-pull connectors. The 24 V DC power supply must be sourced from a Class 2 power supply or protected by an overcurrent protection device rated at no more than 4 A to comply with Zone 2\/22 electrical safety mandates.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cspan style=\"color: #9b2c2c;\"\u003eDisconnect all electrical power sources before initiating installation, wiring, or maintenance. Do not plug or unplug connectors while the circuit is live unless the area is verified to be completely free of ignitable concentrations of flammable gases or dusts. Failure to follow these precautions can result in electrical arcing, explosion, severe injury, or equipment destruction.\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAlign the mounting arm adapter with the 4 M6 threaded holes (100 x 100 mm pattern) on the rear connection block of the panel.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecure the panel to the mounting arm using M6 screws, tightening them to a maximum torque of 3.5 Nm. Do not exceed this torque to prevent thread damage.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect a dedicated low-impedance functional ground (PE) wire to the grounding terminal on the connection block to ensure proper EMI shielding and static dissipation.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eRoute the 24 V DC power cable and the push-pull RJ45 Ethernet cable through the mounting arm, ensuring they are not pinched or subjected to excessive bending radiuses.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInsert and lock the power terminal block and the Ethernet connector, then verify that the USB protective cover is tightly sealed before energizing the system.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106397151595,"sku":"CPX3719-0010","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cpx3719-0010-boppjmjiteh.png?v=1776244096","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-cpx3719-0010-cpx-series-multi-touch-panel-pc","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}