{"product_id":"beckhoff-cx5020-0100-cx5000-series-embedded-pc-cpu-module","title":"Beckhoff CX5020-0100 CX5000 Series Embedded PC CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eIndustrial automation environments requiring robust, fanless computing in a compact DIN-rail form factor utilize the \u003cstrong\u003eBeckhoff CX5020-0100\u003c\/strong\u003e embedded PC. This high-performance industrial controller features an Intel Atom Z530 processor running at 1.6 GHz, providing deterministic execution of PLC, Motion Control, and HMI tasks. Configured as a high-reliability \u003cstrong\u003eCPU module\u003c\/strong\u003e, the device is engineered with an automatic recognition layer that seamlessly interfaces with either EtherCAT Terminals (E-bus) or standard Bus Terminals (K-bus).\u003c\/p\u003e\n\n\u003cp\u003eThe unit features an integrated, hardware-based 1-second UPS that ensures critical persistent data is safely written to the active Compact Flash memory card during sudden power losses. With a diverse physical interface layout and a ruggedized IP20-rated housing, this embedded PC acts as a centralized processing station for demanding decentralized control topologies.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEquipped with an Intel Atom Z530 1.6 GHz single-core processor.\u003c\/li\u003e\n  \u003cli\u003eFeatures dual independent RJ45 gigabit Ethernet interfaces supporting 10\/100\/1000 Mbit\/s rates.\u003c\/li\u003e\n  \u003cli\u003eProvides automatic sensing and integration for E-bus (EtherCAT) and K-bus (Bus Terminal) local I\/O segments.\u003c\/li\u003e\n  \u003cli\u003eContains an integrated 1-second UPS to safeguard up to 1 MB of persistent data.\u003c\/li\u003e\n  \u003cli\u003eSupports fanless operation across an extended operational temperature range.\u003c\/li\u003e\n  \u003cli\u003eIncludes four USB 2.0 ports and a DVI-D video connection for direct peripheral and HMI interfacing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCentralized PLC and motion control in machinery manufacturing.\u003c\/li\u003e\n  \u003cli\u003eProcess control and data acquisition in water and wastewater systems.\u003c\/li\u003e\n  \u003cli\u003ePower generation monitoring and substation automation.\u003c\/li\u003e\n  \u003cli\u003eDecentralized control nodes in material handling and logistics pipelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCX5020-0100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntel Atom Z530, 1.6 GHz clock frequency, single-core\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMain Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e512 MB RAM (expandable ex factory to 1 GB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFlash Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCompact Flash slot (128 MB CF card included, expandable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePersistent Memory\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntegrated 1-second UPS (1 MB on Compact Flash card)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eE-bus (EtherCAT) or K-bus (Bus Terminal), automatic detection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e13 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Supply E-bus\/K-bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 x RJ45 10\/100\/1000 Mbit\/s, 1 x DVI-D, 4 x USB 2.0, 1 x optional interface slot\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDiagnostics LEDs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x power, 1 x TwinCAT status, 1 x flash access, 2 x bus status\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating System Support\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWindows Embedded CE 6, Windows Embedded Standard 2009\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Software\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTwinCAT 2 runtime, TwinCAT 3 runtime (XAR)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTwinCAT 3 Platform Level\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePerformance (40)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e106 mm x 100 mm x 92 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprox. 575 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 degC to +60 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003eConnection Quantity \/ Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRJ45 Ports\u003c\/td\u003e\n      \u003ctd\u003e2 x 10\/100\/1000 Mbit\/s (independent Ethernet subnets)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDVI-D Port\u003c\/td\u003e\n      \u003ctd\u003e1 x Digital Out for direct HMI configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUSB 2.0\u003c\/td\u003e\n      \u003ctd\u003e4 x Type-A USB interfaces for input devices\/storage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Connection\u003c\/td\u003e\n      \u003ctd\u003eTerminal strip interface with auto-bus switching circuitry\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n      \u003ctd\u003eRemovable spring-loaded terminal connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap-on mounting via standard 35 mm DIN rail (EN 60715). Ensure the device is mounted vertically to allow passive convective cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpacing:\u003c\/strong\u003e Maintain a minimum clearance of 30 mm above and below the module for unhindered air circulation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the ground connection point directly to the low-impedance functional earth system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route power lines separately from communication and I\/O signal cables to mitigate high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX (Certified II 3 G Ex nA IIC T4 Gc when configured with CX1900-0105 ordering option)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106447745387,"sku":"CX5020-0100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/cx5020-0100-21uxtnnzza0.png?v=1776244241","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-cx5020-0100-cx5000-series-embedded-pc-cpu-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}