{"product_id":"beckhoff-el3164-ethercat-terminal","title":"Beckhoff EL3164 EtherCAT Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for high-precision analog acquisition within EtherCAT networks, the \u003cstrong\u003eEL3164\u003c\/strong\u003e analog input terminal processes signal voltages ranging from 0 to 10 V. This four-channel module features a single-ended design configuration, converting analog process signals with 16-bit resolution (including sign) for transmission to the higher-level automation controller. Built for industrial environments, it features integrated Distributed Clocks (DC) to ensure highly synchronized microsecond-level timing across the control system.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eEL3164\u003c\/strong\u003e EtherCAT terminal integrates configurable software options to optimize signal quality, including selectable FIR and IIR digital filters, along with limit value monitoring capabilities. This compact 12 mm module communicates directly via the E-bus to leverage high-speed data transfer rates, making it an ideal choice for testing, assembly, and plant automation applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour independent, single-ended analog input channels in a single compact housing\u003c\/li\u003e\n  \u003cli\u003eStandard signal voltage range of 0 to 10 V\u003c\/li\u003e\n  \u003cli\u003eHigh-resolution 16-bit analog-to-digital conversion (including sign)\u003c\/li\u003e\n  \u003cli\u003eSupports Distributed Clocks (DC) for precise synchronization across the network\u003c\/li\u003e\n  \u003cli\u003eSoftware-configurable digital filters (FIR\/IIR) and integrated limit value monitoring\u003c\/li\u003e\n  \u003cli\u003eElectrical isolation of 500 V between the E-bus and the input signal channels\u003c\/li\u003e\n  \u003cli\u003eStandard compact design with status indication LEDs for fast diagnostic troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy industrial process monitoring and automation control loops\u003c\/li\u003e\n  \u003cli\u003ePrecision machine building and high-speed motion synchronization\u003c\/li\u003e\n  \u003cli\u003eData acquisition setups, calibration platforms, and automated test benches\u003c\/li\u003e\n  \u003cli\u003eAutomated HVAC control, water distribution, and environmental monitoring infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEL3164\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4 (single-ended)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSignal Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 bit (incl. sign)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConversion Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 100 us\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt; 200 kOhm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Limit Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003emax. 30 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasuring Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u0026lt; +\/-0.3 % (relative to full scale value)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDistributed Clocks\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCurrent Consumption E-bus\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 130 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (E-bus \/ signal voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e95 %, non-condensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eapprox. 65 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConductor Type\u003c\/th\u003e\n      \u003cth\u003eConnection Cross-Section (Metric)\u003c\/th\u003e\n      \u003cth\u003eConnection Cross-Section (AWG)\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSolid Wire (s)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm²\u003c\/td\u003e\n      \u003ctd\u003eAWG 28 to 14\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStranded Wire (st)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.08 to 2.5 mm²\u003c\/td\u003e\n      \u003ctd\u003eAWG 28 to 14\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWith Ferrule (f)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 to 1.5 mm²\u003c\/td\u003e\n      \u003ctd\u003eAWG 26 to 16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStripping Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"2\"\u003e8 to 9 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Snap directly onto a standard 35 mm DIN rail (conforming to EN 60715). Ensure the locking mechanism is engaged.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e Connect the cable shield directly to the grounding busbar or ground terminal to minimize electromagnetic noise on the analog inputs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Toolless wiring can be performed on solid or ferruled wires using the integrated spring-clamp terminals. For stranded wires without ferrules, actuate the clamp using a small screwdriver.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e Install in a dry, clean cabinet environment with an ambient operating temperature between 0 and +55 degC. Ensure ventilation clearance as required by system architecture guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003eATEX: II 3 G Ex nA IIC T4 Gc\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106531238251,"sku":"EL3164","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/el3164-pivz512q1vk.png?v=1776244451","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-el3164-ethercat-terminal","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}