{"product_id":"beckhoff-il2300-c310-fieldbus-box-plc-box","title":"Beckhoff IL2300-C310 Fieldbus Box PLC Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDecentralized signal routing in demanding automated environments is managed directly at the machine level by the \u003cstrong\u003eBeckhoff IL2300-C310\u003c\/strong\u003e, a rugged \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e fieldbus PLC Box. Engineered to bypass the need for protective control cabinets, this module features a highly resilient IP67 housing and handles communications using standard physical media profiles. Crucial system setups and configuration modifications are achieved easily using the \u003cstrong\u003eKS2000\u003c\/strong\u003e software utility or directly via control-level parameters. It supports \u003cstrong\u003eDP-V1 extensions\u003c\/strong\u003e for enhanced diagnostics, making it an efficient choice for complex topology architectures requiring distributed industrial intelligence.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Baud Rate Detection:\u003c\/strong\u003e Detects and locks onto incoming bus transfer rates automatically up to 12 Mbaud.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDP-V1 Extension Support:\u003c\/strong\u003e Allows acyclic data transfer for advanced configuration, parameterization, and diagnostic feedback.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Environmental Hardening:\u003c\/strong\u003e Rated for IP65, IP66, and IP67 industrial environments, protecting against dust ingress and high-pressure water jets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Standardized Footprint:\u003c\/strong\u003e Designed for direct machine frame mounting, minimizing cable runs and panel space.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandardized Connector Layout:\u003c\/strong\u003e Utilizes standard M12 and M8 circular industrial connectors to simplify replacement and installation cycles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eAutomated manufacturing and robotic assembly lines requiring distributed node architectures.\u003c\/li\u003e\n  \u003cli\u003ePackaging machineries, high-vibration systems, and materials handling conveyors.\u003c\/li\u003e\n  \u003cli\u003eWet areas and washdown environments such as food processing facilities or chemical dosing systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Identifier\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIL2300-C310\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eBus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eData Transfer Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConfiguration Options\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eVia KS2000 configuration software or PLC controller\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eControl Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eLoad Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eAccording to I\/O type specification\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eInternal Current Draw (Box)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85 mA + current consumption of sensors (max. 0.5 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Feed Connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x M8 male connector, 4-pin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Downstream Link\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x M8 female socket, 4-pin\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eControl voltage\/fieldbus: none; Control\/Inputs or Outputs: By I\/O type\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-25 to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eIngress Protection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShock and Vibration Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eEMC Standards\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCertifications\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnector Type\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePin Count \/ Coding\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 0.75rem; font-weight: bold;\"\u003eStandard Purpose\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eBus Interface (In\/Out)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0;\"\u003e5-pin, B-coded M12 socket\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePrimary PROFIBUS DP network connection segment\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Feed Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0;\"\u003e4-pin, M8 male plug\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIncoming 24 V DC control voltage and logic feed\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003ePower Link Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem; border-right: 1px solid #e2e8f0;\"\u003e4-pin, M8 female socket\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDownstream daisy-chain distribution of 24 V DC system power\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen integrating the IL2300-C310 into older system architectures, ensure that your master GSD database matches the hardware revision of the box. Although it serves as a direct drop-in functional unit for legacy decentralized PROFIBUS modules, check software support within TwinCAT 2.x or 3.x configuration profiles to guarantee appropriate addressing offsets for complex I\/O topologies.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eKeep in mind that while the module carries robust sealing specs (IP67), local heat accumulation inside dense non-ventilated mounting locations can shorten the operational lifespan of the unit. Ensure adjacent heat-producing equipment is sufficiently spaced. Avoid exceeding the maximum sensor pass-through current of 0.5 A; attempting to power multiple heavy-duty sensors off a single branch daisy-chained feed will trigger overcurrent conditions.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways use high-quality, pre-assembled M12 PROFIBUS cables to prevent impedance mismatch at high Mbaud rates. If the communication interface behaves erratically, check for proper termination. Active termination should be used at both physical ends of the PROFIBUS network segment. Torque M8 and M12 connectors properly to keep moisture out of unused pins.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Disconnect all electrical feeds before carrying out any mounting or termination procedures. Ensure control lines and load power sources are locked out to prevent accidental power-up. Wait for stored electrostatic charges in downstream line capacitors to dissipate fully before handling wiring harnesses.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; margin-right: 1rem;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eMount the IL2300-C310 physically to a flat, rigid substrate using standard M4 screws. Avoid applying excessive structural tension to the plastic casing.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; margin-right: 1rem;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eConnect the 5-pin, B-coded M12 PROFIBUS input line to the designated interface, ensuring the pins align smoothly before tightening the knurled collar.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; font-weight: bold; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; margin-right: 1rem;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAttach the M8 24 V DC power feed cable. Screw downstream power linkages securely into place, and cover any empty ports with protective dust caps.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106433163627,"sku":"IL2300-C310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/il2300-c310-doaswvlpwuk.png?v=1776244842","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-il2300-c310-fieldbus-box-plc-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}