{"product_id":"beckhoff-ip1012-b518-fieldbus-box-8-channel-digital-input-module","title":"BECKHOFF IP1012-B518 Fieldbus Box 8-Channel Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDesigned for decentralized automation setups without control cabinets, the \u003cstrong\u003eIP1012-B518\u003c\/strong\u003e is an \u003cstrong\u003e8-channel digital input module\u003c\/strong\u003e integrated into a robust CANopen Fieldbus Box housing. This module allows the direct acquisition of up to eight binary control signals from sensors and transducers operating in demanding industrial environments. Equipped with an integrated M12 T-connector, it simplifies fieldbus line routing by facilitating direct looping of the CANopen bus without requiring external splitters or distribution blocks.\u003c\/p\u003e\n\u003cp\u003eWith an extremely fast input filter of 0.2 ms, this \u003cstrong\u003eCANopen Fieldbus Box\u003c\/strong\u003e ensures high-speed signal capture and optimal dynamic performance. It operates with a nominal 24 V DC supply and is sealed within a high-grade polyamide housing, achieving IP65\/66\/67 ingress protection. The device is optimized for mounting directly onto machines, significantly reducing wiring overhead and cabling costs in complex plant configurations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEight independent digital input channels for binary sensor signals.\u003c\/li\u003e\n  \u003cli\u003eIntegrated CANopen bus interface with a built-in T-connector (1 x M12 plug, 5-pin and 1 x M12 socket, 5-pin).\u003c\/li\u003e\n  \u003cli\u003eRapid input filter time of 0.2 ms for time-critical automation applications.\u003c\/li\u003e\n  \u003cli\u003eRobust, fully sealed PA6 (polyamide) XXL housing suited for harsh industrial environments.\u003c\/li\u003e\n  \u003cli\u003eM12 connection technology for digital inputs to ensure reliable, secure cabling.\u003c\/li\u003e\n  \u003cli\u003eM8 connectors for downstream power feed-through to adjacent modules.\u003c\/li\u003e\n  \u003cli\u003eDiagnostic and status LEDs for rapid visual fault isolation on-site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDe-centralized machinery control and assembly systems.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling, packaging, and sorting conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eAutomotive manufacturing and robotic assembly lines.\u003c\/li\u003e\n  \u003cli\u003eProcess plants requiring direct, field-level sensor integration without terminal enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eSystem \u0026amp; Communication Specifications\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP1012-B518\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 kbaud to 1 Mbaud (automatic detection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eI\/O Communication Types\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEvent-driven, cyclic, synchronous, polling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of PDOs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 send and 16 receive process data objects\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMax. Stations (CANopen)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e63 (up to 99 with repeaters)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eDigital Input Parameters\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Connection Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12, screw type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Filter Time\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.2 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"0\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-3 to +5 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e\"1\" Signal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11 to 30 V (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003etyp. 6 mA (EN 61131-2, type 2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSensor Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFrom control voltage, max. 0.5 A total (short-circuit proof)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eElectrical \u0026amp; Mechanical Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eControl Voltage Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + sensor current (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e30 mm x 210 mm x 26.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePA6 (Polyamide)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth colspan=\"2\"\u003eEnvironmental \u0026amp; Operating Limits\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration \u0026amp; Shock Immunity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 and EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Emission \u0026amp; Immunity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-4 and EN 61000-6-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Port\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCANopen In\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug, 5-pin\u003c\/td\u003e\n      \u003ctd\u003ePrimary CAN bus network input connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCANopen Out\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 socket, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eDownstream loop connection via integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 male, 4-pin\u003c\/td\u003e\n      \u003ctd\u003e24 V DC control voltage input feed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M8 female, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower distribution connection for adjacent modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 screw sockets\u003c\/td\u003e\n      \u003ctd\u003eDirect connection for up to 8 field sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the unit directly to the machine frame using the two 3.5 mm diameter fixing holes designed for M3 screws. Ensure a flat surface to prevent mechanical stress on the PA6 housing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Guarantee proper functional grounding to secure high EMC immunity in noisy environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Keep high-voltage cables separated from the CANopen and M12 sensor cables to prevent electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP Rating Integrity:\u003c\/strong\u003e Use IP67-rated mating connectors and protective caps on all unused M12 and M8 ports to maintain the unit’s environmental sealing integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106472190315,"sku":"IP1012-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip1012-b518-qz2sd0gnni0.png?v=1776244899","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip1012-b518-fieldbus-box-8-channel-digital-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}