{"product_id":"beckhoff-ip2300-b310-fieldbus-box-8-channel-digital-i-o-module","title":"Beckhoff IP2300-B310 Fieldbus Box 8-Channel Digital I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDecentralized automation tasks in harsh environments are directly addressed by the \u003cstrong\u003eBeckhoff IP2300-B310\u003c\/strong\u003e, an IP67-rated Fieldbus Box designed to bridge field sensors and actuators directly with a \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e network without requiring a protective control cabinet. This space-saving module integrates \u003cstrong\u003efour digital inputs\u003c\/strong\u003e featuring a fixed 3 ms filter alongside \u003cstrong\u003efour short-circuit-proof digital outputs\u003c\/strong\u003e rated at 0.5 A per channel. Utilizing robust M8 circular connectors, the device minimizes cabling overhead, isolates network noise, and provides local diagnostic feedback via dedicated status LEDs for seamless diagnostics on the factory floor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Machine Mounting:\u003c\/strong\u003e IP67-rated enclosure permits cabinet-free deployment, lowering thermal loads within main enclosures and optimizing cable runs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Fieldbus Connectivity:\u003c\/strong\u003e Embedded PROFIBUS DP interface supporting transmission speeds up to 12 Mbaud with automatic baud rate detection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Digital I\/O:\u003c\/strong\u003e Built with 4 digital inputs (24 V DC, 3 ms filter) and 4 digital outputs (24 V DC, 0.5 A load capacity).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Circuit Protection:\u003c\/strong\u003e Output stages are short-circuit and overload protected, ensuring resilient field operations during actuator failures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eM8 Connector Interface:\u003c\/strong\u003e High-density, screw-lock M8 connections guarantee mechanical stability in high-vibration machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized material handling and heavy conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eRobotic end-of-arm tooling and end-effector sensor consolidation.\u003c\/li\u003e\n  \u003cli\u003ePneumatic valve terminal control in automotive assembly areas.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery requiring distributed IP67-rated I\/O architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold; width: 30%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eModel Reference\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIP2300-B310\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eFieldbus Box (IPxxxx Series)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eFieldbus Protocol\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003ePROFIBUS DP (up to 12 Mbaud)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eDigital Inputs\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4 channels, 24 V DC (nominal)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eInput Filter Delay\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e3.0 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eDigital Outputs\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e4 channels, 24 V DC, short-circuit proof\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eMax. Output Current\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.5 A per channel (2.0 A total module load)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eConnection Style\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eM8 screw-type connectors for digital channels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eControl Voltage\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eCurrent Consumption\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eApprox. 40 mA from control voltage + sensor load\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eIP67 (when all connection ports are sealed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0 degC to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e-25 degC to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0.35 kg (excluding outer shipping carton)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e126 mm x 30 mm x 26.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold; text-align: left;\"\u003eM8 Port Pin\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold; text-align: left;\"\u003eInput Function \/ Assignment\u003c\/th\u003e\n        \u003cth style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold; text-align: left;\"\u003eOutput Function \/ Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e+24 V DC sensor supply (Us)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eNot connected (NC) \/ Reserve\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0 V Ground (GNDs)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003e0 V Ground (GNDp)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px; font-weight: bold;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDigital Input Signal (DI1 to DI4)\u003c\/td\u003e\n        \u003ctd style=\"border: 1px solid #e2e8f0; padding: 10px;\"\u003eDigital Output Signal (DO1 to DO4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis unit serves as a standard Profibus I\/O module. When transitioning from older IP2300 hardware revisions, confirm the rotary address switch behavior matches your master configuration. If moving to industrial Ethernet architectures like EtherCAT, direct equivalents are available within the Beckhoff EP2308-0001 EtherCAT Box series, which features a similar I\/O density and M8 form factor.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen switching highly inductive DC loads (such as heavy pneumatic solenoids or magnetic brakes), flyback currents can degrade the internal output switches over time. While the digital outputs are electronically protected, deploying an external flyback diode directly at the inductive load terminals is recommended to maximize hardware longevity. Additionally, avoid exceeding the maximum group limit of 2.0 A total output current across all active output channels to prevent thermal shutdown of the internal driver IC.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe PROFIBUS DP address must be defined manually using the two decimal rotary switches protected beneath the clear threaded cap on the front of the module. To ensure the IP67 seal rating remains valid, verify that the clear cap is tightened to its proper torque specification (0.6 Nm) and that any unused M8 ports are securely sealed using standard IP67-rated protective plugs.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all power sources supplying the host control panel and field equipment before beginning physical mounting or wiring of this fieldbus module. Dangerous electrical shock risks, short-circuits, and unexpected actuator triggering may occur if connections are modified while power is active.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecurely mount the fieldbus box to a flat, rigid machine surface using two M4 bolts through the pre-cast mounting holes. Ensure the surface is free from sharp vibration sources.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConfigure the desired PROFIBUS address (from 1 to 99) via the integrated rotary switches before connecting power or fieldbus cables.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the incoming fieldbus cable to the designated PROFIBUS interface and terminate the line if the module sits at the physical end of the bus trunk.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAttach the M8 I\/O cables, ensuring the locking collars are fully tightened to maintain the IP67 water and dust seal. Cap any unused channels immediately.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106456330603,"sku":"IP2300-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2300-b310-pufilxra35a.png?v=1776244983","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip2300-b310-fieldbus-box-8-channel-digital-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}