{"product_id":"beckhoff-ip2310-b810-fieldbus-box-4-channel-digital-input-output-module","title":"Beckhoff IP2310-B810 Fieldbus Box 4-Channel Digital Input\/Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDecentralized field acquisition and control is handled directly at the machine level by the \u003cstrong\u003eBeckhoff IP2310-B810\u003c\/strong\u003e Fieldbus Box. This robust IP67-rated module integrates \u003cstrong\u003efour digital inputs\u003c\/strong\u003e and \u003cstrong\u003efour digital outputs\u003c\/strong\u003e into a single compact device, operating via a serial peer-to-peer connection. Designed to withstand harsh industrial environments without requiring an additional protective enclosure, it communicates using an open, documented protocol with support for variable baud rates up to 38.4 kbaud. System parameters and I\/O status can be configured and diagnosed seamlessly using the KS2000 software package.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Field Integration:\u003c\/strong\u003e Fully sealed PA6 polyamide housing providing IP65, IP66, and IP67 protection ratings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMixed I\/O Configuration:\u003c\/strong\u003e Equipped with 4 digital inputs (0.2 ms filter time) and 4 digital outputs (0.5 A per channel).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSerial Peer-to-Peer Bus Link:\u003c\/strong\u003e Reliable data transfer via shielded copper cabling up to a distance of 15 meters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Sensor supplies and individual output channels feature independent short-circuit protection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandardized Connections:\u003c\/strong\u003e Employs industry-standard M8 and M12 connections for fieldbus and auxiliary power lines, alongside 8 mm snap-type I\/O ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized material handling and conveyor automation.\u003c\/li\u003e\n  \u003cli\u003eOn-machine sensor and actuator concentration in automotive assembly lines.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery operating in wet, wash-down, or high-vibration zones.\u003c\/li\u003e\n  \u003cli\u003eDistributed pneumatic valve control terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; width: 35%;\"\u003eManufacturer\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP2310-B810\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eNumber of Channels\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4 digital inputs + 4 digital outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eBus Interface\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1 x M12 socket, 5-pin, B-coded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eData Transfer Rates\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eInput Filter Time\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.2 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003e\"0\" Signal Voltage\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-3 to +5 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003e\"1\" Signal Voltage\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e11 to 30 V (6 mA input current, EN 61131-2, type 2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eRated Load Voltage\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eMax. Output Current\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.5 A per channel (individually short-circuit proof)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003ePower Supply Input\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eBox Supply Current\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e45 mA + sensor current (max. 0.5 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eElectrical Isolation\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eControl voltage\/fieldbus: Yes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eHousing Material\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePA6 (Polyamide)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eOperating Temperature\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eStorage Temperature\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e30 mm x 175 mm x 26.5 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eWeight\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e210 g\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eCountry of Origin\u003c\/th\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #e2e8f0; background-color: #f7fafc;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003ePort Reference\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eConnector Type\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunctional Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eBus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eM12 socket, 5-pin, B-coded\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSerial communication link (open protocol)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePower Supply Feed\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eM8 male socket, 4-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eControl voltage (Us) and load voltage (Up) input\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDownstream Power\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eM8 female socket, 4-pin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePower pass-through to subsequent Fieldbus Boxes\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDigital Inputs (I1 to I4)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8 mm snap-type connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e24 V DC sensors with 0.2 ms signal filtration\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDigital Outputs (O1 to O4)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e8 mm snap-type connection\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eActuators, solenoid valves, or lamps up to 0.5 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eAlternative Models \u0026amp; Compatibility:\u003c\/strong\u003e The IP2310-B810 relies on a serial point-to-point physical connection. If transitioning system networks to EtherCAT or PROFIBUS, this module is not directly cross-compatible without a coupler box. When replacing legacy IP2310 units, verify the default serial transmission rate (baud rate) match; inconsistencies can cause communication timeouts or frame drops across the 15-meter loop.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eApplication Pitfalls \u0026amp; Engineering Notes:\u003c\/strong\u003e Although individual outputs are short-circuit proof to 1.5 A typically, the total box sensor supply has a cumulative limit of 0.5 A. Engineers must calculate total current draw of all four connected sensors. Running inductive loads without external flyback diodes is supported by the internal clamping circuit, but excessive cycling of high-inductance coils can generate localized thermal stress in enclosed areas with ambient temperatures approaching 55 degC.\u003c\/p\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\u003cstrong\u003eCommissioning \u0026amp; Wiring Tips:\u003c\/strong\u003e To ensure reliable communication at 38.4 kbaud over long lines, use only double-shielded copper cable with a minimum cross-section of 2 x 0.25 mm². Ground the shield on the master controller side. Avoid routing the M8 sensor cables parallel to high-voltage variable frequency drive (VFD) output cables to prevent cross-talk on the 0.2 ms digital input lines.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"margin: 0; font-weight: bold; color: #9b2c2c;\"\u003eCRITICAL WARNING: SAFETY FIRST\u003c\/p\u003e\n  \u003cp style=\"margin: 5px 0 0 0; color: #9b2c2c; font-size: 0.95rem;\"\u003eAlways completely isolate and de-energize both the auxiliary power (Us) and load voltage (Up) supply lines before mounting, cleaning, or changing any M8\/M12 connections. Failure to follow this protocol can result in transient arcs, sensor failure, or unexpected field actuator state changes.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 15px; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold; margin-right: 15px; font-size: 0.9rem;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eMount the module on a flat machine frame surface using the two integrated 3.5 mm diameter fixing holes designed for standard M3 screws. Do not exceed 0.8 Nm tightening torque to avoid cracking the polyamide shell.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold; margin-right: 15px; font-size: 0.9rem;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eEnsure the IP67 sealing integrity by inserting and fully tightening all M8 and M12 mating connectors. Hand-tighten until the tactile seal resistance is felt, then turn an additional 1\/4 turn.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"display: inline-flex; align-items: center; justify-content: center; background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; font-weight: bold; margin-right: 15px; font-size: 0.9rem;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eInstall protective plastic caps on any unused 8 mm snap-type or M8 downstream sockets to maintain environmental protection levels (IP65\/66\/67).\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106529829227,"sku":"IP2310-B810","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2310-b810-nudurjodnsv.png?v=1776245015","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip2310-b810-fieldbus-box-4-channel-digital-input-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}