{"product_id":"beckhoff-ip2330-b310-fieldbus-box","title":"Beckhoff IP2330-B310 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nFor direct installation in the field without protective enclosures, the \u003cstrong\u003eBeckhoff IP2330-B310\u003c\/strong\u003e serves as a robust PROFIBUS DP interface block featuring integrated digital I\/O channels. By combining \u003cstrong\u003e4 digital inputs\u003c\/strong\u003e and \u003cstrong\u003e4 digital outputs\u003c\/strong\u003e in a single, high-protection module, this decentralized station minimizes wiring overhead and optimizes signal routing on modern automated production floors. The device communicates directly with the host PLC via a high-speed PROFIBUS DP connection, executing commands with minimal latency and high operational reliability.\n\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Field Mounting:\u003c\/strong\u003e IP67-rated housing allows installation outside control cabinets, reducing cabling paths.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDigital Input Configuration:\u003c\/strong\u003e 4 channels rated at 24 V DC with a rapid 0.2 ms input filter for precise signal registration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Outputs:\u003c\/strong\u003e 4 digital outputs delivering up to 2 A per channel, fully short-circuit proof.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Standard Connectors:\u003c\/strong\u003e M8 (8 mm) snap-on round connectors for reliable sensor and actuator integration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Form Factor:\u003c\/strong\u003e Small-footprint modular design with integrated mounting holes for direct machine frame attachment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized material handling and heavy-duty conveyor systems.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly lines requiring localized sensor and actuator distribution.\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery operating in washdown or high-dust zones.\u003c\/li\u003e\n  \u003cli\u003eRobotic end-of-arm tooling control interfaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eTechnical Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eBeckhoff Automation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eModel Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eIP2330-B310\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eProtocol \/ Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePROFIBUS DP\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eData Transfer Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eAutomatic detection up to 12 Mbaud\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eDigital Inputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e4 channels (24 V DC, filter time 0.2 ms)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eDigital Outputs\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e4 channels (24 V DC, 2 A maximum, short-circuit protected)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eField Connection Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eM8 (diameter 8 mm) snap-on connectors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePower Supply Voltage\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0 degC to 55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e-25 degC to 85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eIP Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eIP65 \/ IP66 \/ IP67 (when fully connected and sealed)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e175 mm x 45 mm x 35 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eConnection Pin (M8 Signal)\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eFunction \/ Signal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSensor \/ Actuator Supply (+24 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eReference Ground (0 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0; font-weight: bold;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eInput Signal (Channels 1-4) \/ Output Signal (Channels 1-4)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe IP2330-B310 operates as an integrated IP67 equivalent to the coupling of a Beckhoff BK3120\/BK3150 PROFIBUS Coupler with KL1404 and KL2404 Bus Terminals. When executing drop-in replacements, ensure that the GSD file installed on the master PROFIBUS controller matches the correct revision level. Older revisions of this Fieldbus Box may have different parameter mappings in hardware configurations; verify whether the GSD file supports the diagnostic structures of newer hardware variants.\n\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nWhile individual digital outputs can supply up to 2 A, the cumulative load across all outputs is restricted by the absolute power distribution limit of the module's power feed-in line (typically up to 4 A in series-connected topologies). If driving heavy inductive loads like high-current solenoid valves continuously, mount the module on a metallic plate to aid thermal dissipation and prevent localized thermal shut-down. \n\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003e\nThe PROFIBUS DP address is configured manually via the two rotary switches located behind the screw-down protection cap. Note that the station address cannot be changed dynamically; address modifications only become active upon cycling the system control power (24 V DC). Always ensure the protective screw cap is fully tightened to a minimum of 0.5 Nm after address configuration to maintain the module's IP67 ingress protection rating.\n\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003e\n    Before mounting or servicing this Fieldbus Box, isolate and lock out all 24 V DC control and load power supplies. Ingress of moisture or conductive debris into open, unsealed M8\/M12 connectors during installation will cause internal short-circuiting and permanent bus interface failure.\n  \u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Mount the IP2330-B310 onto a flat, vibration-resistant surface using two M3 or M4 screws passing through the integrated mounting slots on the outer edges.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Remove the protective cap and configure the target PROFIBUS node address using the dual rotary decimal switches. Reseal the switch cover tightly.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Connect the PROFIBUS signal cables to the designated bus interface connectors. Securely tighten all coupled network connections.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cdiv style=\"color: #2d3748;\"\u003e\n      Install M8 sealing caps on any unused input\/output channels to prevent ingress of dirt, cutting oils, or moisture. Apply 24 V DC power and verify system diagnostics.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106472517995,"sku":"IP2330-B310","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip2330-b310-xae4rscozkl.png?v=1776245057","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip2330-b310-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}