{"product_id":"beckhoff-ip3112-b318-fieldbus-box","title":"Beckhoff IP3112-B318 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIntegrating decentralized field signals directly into PROFIBUS DP architectures, the \u003cstrong\u003eBeckhoff IP3112-B318\u003c\/strong\u003e functions as a highly robust \u003cstrong\u003eFieldbus Box\u003c\/strong\u003e designed for harsh operational environments. This module enables direct connection of physical industrial sensors and actuators without the need for an additional protective control cabinet. Operating seamlessly on PROFIBUS systems, it supports dynamic configuration options and handles data rates up to 12 Mbaud with automatic detection. The fully sealed housing delivers excellent dust and water ingress protection, making it suitable for direct machine mounting in heavy manufacturing environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eDirect integration with \u003cstrong\u003ePROFIBUS DP\u003c\/strong\u003e networks supporting DP-V1 extensions.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eAutomatic detection of communication transmission rates up to \u003cstrong\u003e12 Mbaud\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eStandardized \u003cstrong\u003eB-coded M12\u003c\/strong\u003e physical bus interface with integrated T-connector.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eRugged housing rated for \u003cstrong\u003eIP65, IP66, and IP67\u003c\/strong\u003e protection classes.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eM8 power supply connectors supporting simple daisy-chaining to downstream modules.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eFlexible configuration possibilities via \u003cstrong\u003eKS2000\u003c\/strong\u003e software or directly through the main controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eCabinet-free automation architectures in automotive production lines.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eMaterial handling, sorting, and conveyor systems requiring localized physical inputs.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eHeavy industrial plants subject to high vibration, moisture, and fine particulates.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 0.5rem;\"\u003eProcess industries requiring decentralized data collection over extended distances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; color: #1a365d; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; color: #1a365d; font-weight: bold;\"\u003eValue \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eModel Number \/ SKU\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP3112-B318\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtocol \/ Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003ePROFIBUS DP (with DP-V1 extensions support)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eData Transfer Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUp to 12 Mbaud (automatic detection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eControl Voltage Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eBox Current Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e85 mA + sensor current (maximum 0.5 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eControl voltage to fieldbus: No; Control voltage to I\/O: according to I\/O type\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e0 to +55 degC (Celsius)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e-25 to +85 degC (Celsius)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eVibration \/ Shock Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eEMC Immunity \/ Emission\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eApprovals\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e2.00 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e126 x 30 x 27 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"text-align: left; padding: 8px; color: #1a365d; font-weight: bold;\"\u003eConnection Type\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; color: #1a365d; font-weight: bold;\"\u003eHardware Interface\u003c\/th\u003e\n        \u003cth style=\"text-align: left; padding: 8px; color: #1a365d; font-weight: bold;\"\u003ePin Allocation \/ Purpose\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFieldbus Input\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M12 plug (B-coded)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e5-pin PROFIBUS DP connection with integrated tee-connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eFieldbus Output\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M12 socket (B-coded)\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e5-pin downstream PROFIBUS DP connection\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Feed\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M8 male socket\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4-pin control voltage input (24 V DC)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePower Downstream\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e1 x M8 female socket\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e4-pin control voltage pass-through for downstream modules\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP3112-B318 belongs to the Beckhoff Fieldbus Box family. It is physically and electrically drop-in compatible with standard PROFIBUS DP networks utilizing B-coded M12 cabling. Parameters can be assigned using the standard GSD configuration file provided by the manufacturer or the specialized KS2000 configuration tool interface. Ensure firmware versions in your master controller support standard DP-V1 acyclic read\/write data records for diagnostic access.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen daisy-chaining multiple IP-series modules using the M8 power distribution interfaces, calculate total cumulative current draw meticulously. The M8 connectors are rated for a maximum total feed current of 4 A. Exceeding this thermal threshold will cause permanent damage to the internal power plane. To prevent voltage drops across complex topologies, execute a fresh power feed loop injection whenever the maximum sensor load approaches 4 A.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways utilize shielded twisted-pair copper cabling specifically rated for PROFIBUS DP transmission (typically 2 x 0.25 mm2 with a characteristic impedance of 150 ohms). To guarantee structural integrity of the IP67 seal rating, tighten all M8\/M12 connectors using a calibrated torque wrench set to exactly 0.4 Nm for M8 and 0.6 Nm for M12. Unused connector sockets must be capped using certified industrial sealing plugs.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0; font-size: 0.95rem;\"\u003eDo not perform hot-plugging or wiring modifications while the 24 V DC power network is live. Ensure all power supplies are de-energized and locked out before initiating the mounting or cable mating process. Improper grounding of the shield line can lead to communication degradation and physical hardware damage due to ground loops.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the Fieldbus Box directly to the machine structure using the integrated mounting flanges. Ensure the mounting plane is flat to avoid structural tension on the housing body.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eEstablish the physical PROFIBUS connection using the B-coded M12 connectors, verifying that the integrated T-connector is correctly seated for continuous line topology.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the 24 V DC control voltage line to the M8 feed connector. Ensure correct polarity to prevent reverse bias currents.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; font-size: 0.9rem;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecure all unused ports with screw-on IP67 caps. Turn on power, configure the device address using the master controller software, and perform logical validation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106448990571,"sku":"IP3112-B318","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3112-b318-c4uatgggk4z.png?v=1776245081","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip3112-b318-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}