{"product_id":"beckhoff-ip3112-b518-fieldbus-box","title":"Beckhoff IP3112-B518 Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDecentralized automation tasks require rugged hardware capable of operating outside traditional control cabinets. The \u003cstrong\u003eBeckhoff IP3112-B518\u003c\/strong\u003e Fieldbus Box meets this demand by providing direct connection of peripheral signals to CANopen networks in harsh industrial environments. By housing the communication and I\/O interface in a compact, environmentally sealed module, this device minimizes cabling effort and reduces cabinet space requirements.\u003c\/p\u003e\n\n\u003cp\u003eOperating as a high-performance CANopen node, the \u003cstrong\u003eIP3112-B518\u003c\/strong\u003e supports up to 16 send and 16 receive Process Data Objects (PDOs), enabling highly flexible data transmission. It features advanced CANopen communication profiles including life guarding, node guarding, emergency object handling, variable mapping, and store\/restore parameters. Configuration can be executed either via the KS2000 service software or directly from the master controller using Service Data Objects (SDOs). The integrated M12 T-connector simplifies bus cabling by allowing direct loop-through of the network medium without additional external splitters.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDirect integration into CANopen industrial networks.\u003c\/li\u003e\n  \u003cli\u003eSupports up to 16 send and 16 receive Process Data Objects (PDOs) for flexible data mapping.\u003c\/li\u003e\n  \u003cli\u003eAutomatic detection of network data transfer rates from 10 kbaud up to 1 Mbaud.\u003c\/li\u003e\n  \u003cli\u003eRobust environmental protection class IP65, IP66, and IP67, enabling cabinet-free mounting.\u003c\/li\u003e\n  \u003cli\u003eIntegrated M12 T-connector interface for efficient bus wiring and daisy-chaining.\u003c\/li\u003e\n  \u003cli\u003eComprehensive diagnostics via built-in node guarding, life guarding, and emergency object services.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive manufacturing and assembly lines.\u003c\/li\u003e\n  \u003cli\u003eMaterial handling systems and industrial conveyors.\u003c\/li\u003e\n  \u003cli\u003eWastewater treatment facilities.\u003c\/li\u003e\n  \u003cli\u003eFood processing and packaging machinery.\u003c\/li\u003e\n  \u003cli\u003eDistributed sensor\/actuator networks in heavy machine manufacturing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBeckhoff\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP3112-B518\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCANopen Fieldbus Box\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10 kbaud to 1 Mbaud (automatic detection)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNumber of PDOs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e16 send \/ 16 receive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated T-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply (Control)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e24 V DC (-15 percent \/ +20 percent)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Supply Connections\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e500 V (control voltage \/ fieldbus)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCommunication Modes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEvent-driven, cyclic, synchronous, polling\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP65, IP66, IP67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 kg (including shipping packaging)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Type\u003c\/th\u003e\n      \u003cth\u003eInterface Style\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface (Inlet)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 Plug, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eIncoming CANopen signal and bus power reference\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBus Interface (Outlet)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM12 Socket, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eOutgoing loop-through CANopen signal (integrated T-connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Feed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 Male, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eControl voltage supply (24 V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Downstream\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM8 Female, 4-pin\u003c\/td\u003e\n      \u003ctd\u003ePower distribution to downstream Fieldbus Boxes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsure the unit is mounted on a flat, vibration-resistant surface using the designated mounting holes.\u003c\/li\u003e\n  \u003cli\u003eTighten all unused M12 and M8 connection ports with verified protective caps to maintain the IP67 sealing integrity.\u003c\/li\u003e\n  \u003cli\u003eRoute bus lines and power cables separately from high-voltage motor or drive cabling to avoid electromagnetic interference.\u003c\/li\u003e\n  \u003cli\u003eEnsure correct termination of the CANopen network by installing a 120-Ohm terminating resistor at both physical ends of the bus segment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106444861803,"sku":"IP3112-B518","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip3112-b518-ygpgfmqn0kh.png?v=1776245084","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip3112-b518-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}