{"product_id":"beckhoff-ip5009-b318-fieldbus-box-ssi-sensor-interface","title":"Beckhoff IP5009-B318 Fieldbus Box SSI Sensor Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDecentralized acquisition of high-frequency sensor data is directly enabled by the \u003cstrong\u003eBeckhoff IP5009-B318\u003c\/strong\u003e, an IP67-rated PROFIBUS DP Fieldbus Box designed for harsh operating environments. This module interfaces absolute encoders or displacement sensors utilizing the SSI (Synchronous Serial Interface) protocol, transferring data directly to the higher-level master controller via PROFIBUS DP. With integrated B-coded M12 connections acting as a built-in T-connector, the module allows for direct bus line looping without requiring external active junctions. Configuration and parameters can be easily adjusted using the \u003cstrong\u003eKS2000\u003c\/strong\u003e software tool or directly via controller-driven DP-V1 acyclic slot communication.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePROFIBUS DP Compatibility:\u003c\/strong\u003e Complete support for baud rates up to 12 Mbaud with integrated automatic speed detection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Enclosure Design:\u003c\/strong\u003e Full IP65, IP66, and IP67 protection ratings, eliminating the need for protective control cabinets in the field.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Loop-Through:\u003c\/strong\u003e M12 male and female B-coded interfaces enable simple daisy-chaining of the fieldbus line.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Configuration:\u003c\/strong\u003e Supports DP-V1 communication extensions for dynamic, runtime parameter adjustments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReliable Power Distribution:\u003c\/strong\u003e Standardized M8 connectors for control voltage and downstream load distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eDecentralized SSI absolute encoder feedback in packaging and material handling systems.\u003c\/li\u003e\n  \u003cli\u003eHigh-accuracy position sensing on outdoor linear axes and heavy machinery.\u003c\/li\u003e\n  \u003cli\u003eAutomotive assembly lines requiring direct, field-mounted sensor integration.\u003c\/li\u003e\n  \u003cli\u003eWind turbine pitch control systems and waste-water treatment plants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP5009-B318\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFieldbus Protocol\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePROFIBUS DP (with DP-V1 support)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eData Transfer Rates\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUp to 12 Mbaud (automatic detection)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eFieldbus Interface\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x M12 socket (5-pin), 1 x M12 plug (5-pin), B-coded\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eControl Voltage Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 24 V DC (-15% \/ +20%)\"\u003e24 V DC (-15% \/ +20%)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCurrent Consumption (Box Supply)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e85 mA + sensor load (max. 0.5 A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePower Feed \/ Downstream\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1 x M8 male socket (4-pin) \/ 1 x M8 female socket (4-pin)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eIsolation (Control \/ Fieldbus)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eNone (electrical isolation is determined by sensor configuration)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCycle Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eApprox. 0.5 ms (for typical network of 10 boxes with 32-bit I\/O each)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e0 to +55 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e-25 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eIP65 \/ IP66 \/ IP67 (conforms to EN 60529)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eVibration\/Shock Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eApprovals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCE, UL\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d; text-align: left;\"\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eInterface Connection\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003ePin Number\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; font-weight: bold; color: #1a365d;\"\u003eSignal Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd rowspan=\"5\" style=\"padding: 0.75rem; font-weight: bold; vertical-align: top;\"\u003ePROFIBUS DP M12 (B-coded)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eVP (+5 V DC for active termination)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRxD\/TxD-N (A-line, Green)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDGND (Data Ground)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRxD\/TxD-P (B-line, Red)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 5\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eShield\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd rowspan=\"4\" style=\"padding: 0.75rem; font-weight: bold; vertical-align: top;\"\u003ePower M8 (Feed Connection)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 1\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e+24 V DC control voltage (Us)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 2\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e+24 V DC load voltage (Up)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 3\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGND (Us)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003ePin 4\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGND (Up)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe IP5009-B318 replaces several legacy non-coupled configurations by bringing SSI decoding down to the machine level. Ensure your GSD file is updated to include the exact module parameters to prevent cyclic data exchange errors with older master systems. For setups utilizing the EtherCAT network topology rather than PROFIBUS, the EP5001-0002 serves as the native EtherCAT fieldbus equivalent.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen daisy-chaining multiple boxes via the M8 power distribution interfaces, calculate the total voltage drop. The cumulative control current (Us) should not exceed 4 A across a single segment to prevent high thermal stress on the internal bus rails. Since control voltage and fieldbus communications do not share electrical isolation inside the module, run all system fieldbus lines in separated, shielded trays to prevent EMI-induced communication dropouts.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1.5rem;\"\u003eFor optimal performance, use a terminating resistor if the IP5009-B318 acts as the physical last node in the PROFIBUS segment. Standard active termination can be accomplished using an M12 B-coded terminator connected to the downstream socket interface. Ensure the SSI sensor cable is shielded and connected directly to the designated housing shield collar to maintain signal integrity during dynamic motor acceleration cycles.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cp style=\"color: #9b2c2c; font-weight: bold; margin: 0 0 0.5rem 0;\"\u003eCRITICAL SAFETY WARNING\u003c\/p\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate all electrical power sources before initiating installation, removal, or wiring processes. Verify that both control and load voltages (Us and Up) are fully de-energized. Failure to strictly follow these safety steps can cause immediate physical danger or catastrophic failures to connected high-precision SSI sensors.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 0.75rem; display: flex; align-items: center;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eMount the Fieldbus Box on a flat, vibration-free surface using two M4 mounting screws.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 0.75rem; display: flex; align-items: center;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecurely torque the M12 B-coded PROFIBUS cable connectors to prevent moisture and dust ingress.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 0.75rem; display: flex; align-items: center;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eWire the M8 power supply connection, ensuring polarity matches for both control (Us) and load (Up) segments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 1.5rem; display: flex; align-items: center;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 0.75rem; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n  \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify connection status and baud rate sync via the diagnostic LEDs prior to running system processes.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106424381803,"sku":"IP5009-B318","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip5009-b318-ntwkm14kvja.png?v=1776245102","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip5009-b318-fieldbus-box-ssi-sensor-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}