{"product_id":"beckhoff-ip5009-b528-devicenet-fieldbus-box","title":"BECKHOFF IP5009-B528 DeviceNet Fieldbus Box","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eDecentralized field automation requirements are directly addressed by the \u003cstrong\u003eIP5009-B528\u003c\/strong\u003e, a high-performance \u003cstrong\u003eDeviceNet fieldbus box\u003c\/strong\u003e engineered by Beckhoff for direct mounting in demanding industrial environments. This station connects digital and analog peripheral signals directly to DeviceNet networks without requiring a protective control cabinet. By utilizing integrated M12 tee-connector ports and M8 power feed-through interfaces, this module enables efficient line-topology wiring directly on the machinery.\u003c\/p\u003e\n\n\u003cp\u003eThe module supports configuration flexibility through either the Beckhoff KS2000 software suite or directly via the master controller using explicit messaging. The integrated electronics dynamically adapt to network transfer rates up to 500 kbaud. Electrical isolation of 500 V between the control voltage and the fieldbus line provides robust protection against transient noise and grounding loops, securing reliable I\/O data transmission across varying plant distances.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeviceNet Integration:\u003c\/strong\u003e Full compatibility with DeviceNet physical layer and protocol specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAutomatic Baud Rate Detection:\u003c\/strong\u003e Automatically syncs with the master station at transmission speeds up to 500 kbaud.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntegrated Tee-Connector:\u003c\/strong\u003e Built-in 1 x M12 plug (5-pin) and 1 x M12 socket (5-pin) interfaces eliminate the need for external T-pieces.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible I\/O Mapping:\u003c\/strong\u003e Handles digital and analog peripheral signals based on the specific module extension and I\/O layout.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Daisy-Chaining:\u003c\/strong\u003e Features an M8 male input and M8 female downstream power connection to feed control and load voltages.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Environmental Housing:\u003c\/strong\u003e Rated up to IP67 for dust and water ingress protection, allowing direct machinery mounting without enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomotive assembly lines and robotic welding cells\u003c\/li\u003e\n  \u003cli\u003ePackaging machinery and material handling conveyor networks\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater processing systems with decentralized control nodes\u003c\/li\u003e\n  \u003cli\u003eGeneral factory automation requiring IP67 distributed field I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eManufacturer\u003c\/strong\u003e\n      \u003ctd\u003eBECKHOFF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\n      \u003ctd\u003eIP5009-B528\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eFieldbus Protocol\u003c\/strong\u003e\n      \u003ctd\u003eDeviceNet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eData Transfer Rates\u003c\/strong\u003e\n      \u003ctd\u003eAutomatic detection up to 500 kbaud\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eBus Interface\u003c\/strong\u003e\n      \u003ctd\u003e1 x M12 plug (5-pin), 1 x M12 socket (5-pin) (tee-connector integrated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eData Transfer Medium\u003c\/strong\u003e\n      \u003ctd\u003eShielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eControl Voltage Supply\u003c\/strong\u003e\n      \u003ctd\u003e24 V DC (-15 % \/ +20 %)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eLoad Voltage Supply\u003c\/strong\u003e\n      \u003ctd\u003eAccording to connected I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003ePower Supply Connection\u003c\/strong\u003e\n      \u003ctd\u003eFeed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eBox Supply Current\u003c\/strong\u003e\n      \u003ctd\u003e45 mA + current consumption of sensors (max. 0.5 A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e\n      \u003ctd\u003eControl voltage\/fieldbus: 500 V; Control voltage\/I\/O: according to I\/O type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eI\/O Communication Types\u003c\/strong\u003e\n      \u003ctd\u003eBit strobe, polling, cyclic, change of state (COS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\n      \u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\n      \u003ctd\u003e-25 to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eVibration\/Shock Resistance\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 60068-2-6 \/ EN 60068-2-27\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eEMC Immunity\/Emission\u003c\/strong\u003e\n      \u003ctd\u003eConforms to EN 61000-6-2 \/ EN 61000-6-4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eProtection Class\u003c\/strong\u003e\n      \u003ctd\u003eIP65\/66\/67 (conforms to EN 60529)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eInstallation Position\u003c\/strong\u003e\n      \u003ctd\u003eVariable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cstrong\u003eShipping Weight\u003c\/strong\u003e\n      \u003ctd\u003e2.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Interface\u003c\/th\u003e\n      \u003cth\u003eConnector Type\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Input\u003c\/td\u003e\n      \u003ctd\u003eM12 Plug, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet upstream fieldbus network connection\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eBus Output\u003c\/td\u003e\n      \u003ctd\u003eM12 Socket, 5-pin\u003c\/td\u003e\n      \u003ctd\u003eDeviceNet downstream connection (integrated T-connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Input\u003c\/td\u003e\n      \u003ctd\u003eM8 Male Socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eFeed control voltage (24 V DC) and sensor\/actuator power\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Output\u003c\/td\u003e\n      \u003ctd\u003eM8 Female Socket, 4-pin\u003c\/td\u003e\n      \u003ctd\u003eDownstream control and load voltage loop-through\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the unit to a flat, rigid machine surface using the integrated mounting flanges. Avoid mounting orientations that expose the connection points to continuous fluid pooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure a low-impedance connection to the machine ground. Use the provided mounting holes or local functional earth contacts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCabling and Torquing:\u003c\/strong\u003e All unused M12 and M8 ports must be sealed with appropriate protective caps to maintain the IP65\/66\/67 rating. Tighten mating connectors to the manufacturer-specified torque limits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route fieldbus communication cables away from high-noise power lines, motor cables, and variable frequency drives to prevent electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106423267691,"sku":"IP5009-B528","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ip5009-b528-humddql4je3.png?v=1776245105","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ip5009-b528-devicenet-fieldbus-box","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}