{"product_id":"beckhoff-ks3064-bus-terminal-4-channel-analog-input-module","title":"Beckhoff KS3064 Bus Terminal 4-Channel Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eTo facilitate precise voltage acquisition in dense processing environments, the \u003cstrong\u003eBeckhoff KS3064\u003c\/strong\u003e analog input terminal digitizes field-side signals from 0 to 10 V DC with 12-bit resolution. As part of the premium pluggable \u003cstrong\u003eKSxxxx\u003c\/strong\u003e series, this 4-channel single-ended module integrates highly reliable performance with a hot-swappable terminal block design, enabling quick hardware change-outs without disturbing existing field wiring. It communicates directly with the primary industrial controller via the standard K-bus interface, combining high processing efficiency with minimal space requirements.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFour Single-Ended Inputs:\u003c\/strong\u003e Allows simultaneous monitoring of four independent 0 to 10 V analog signals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePluggable Wiring Interface:\u003c\/strong\u003e Front-facing tension-clamp connector block is easily removable, reducing maintenance downtime and simplifying cabinet retrofits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e12-Bit Analog-to-Digital Conversion:\u003c\/strong\u003e Delivers sharp resolution for highly accurate PLC and DCS monitoring applications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides robust 500 V electrical isolation between the internal K-bus and the process circuitry, defending control hardware from voltage spikes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact 12 mm Footprint:\u003c\/strong\u003e Modular housing saves valuable DIN-rail space inside control panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Sensor Monitoring:\u003c\/strong\u003e Acquires signal inputs from flow meters, pressure transmitters, and distance sensors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC Control Integration:\u003c\/strong\u003e Collects temperature and humidity voltage signals from environmental monitoring units.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMachinery Control Platforms:\u003c\/strong\u003e Acts as the analog interface for OEM assembly equipment, handling variable system feedback.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eValue \/ Detail\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBeckhoff\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eKS3064\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e4-Channel Analog Input (Single-Ended)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSignal Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0 to 10 V DC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eInternal Resistance\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e\u0026gt; 200 kOhm (typical)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eResolution\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e12 bit\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConversion Time\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eApprox. 4 ms\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMeasuring Error\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e\u0026lt; +\/- 0.3 % (relative to full scale value)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eK-Bus Current Consumption\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eTyp. 85 mA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eElectrical Isolation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e500 V (K-bus \/ signal voltage)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnection Method\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePluggable spring-actuated terminal block\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConnection Cross-Section\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSolid\/Stranded: 0.08 to 1.5 mm2 (AWG 28 to 16)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-25 to +60 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-40 to +85 degC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProtection Class\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eIP20\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eEx Marking\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eII 3 G Ex nA IIC T4 Gc (ATEX certified)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eGermany\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e12 mm x 100 mm x 68 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eUnit Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e0.08 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections \u0026amp; Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eTerminal Pin Number\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eSignal Type\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold;\"\u003eDescription\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e1\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eInput 1 (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage input channel 1 (0 to 10 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e5\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eInput 2 (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage input channel 2 (0 to 10 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e2\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eInput 3 (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage input channel 3 (0 to 10 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e6\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eInput 4 (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eVoltage input channel 4 (0 to 10 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e3, 7, 4, 8\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCommon GND\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eInternal common reference ground points (0 V)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #1a365d; font-size: 1.1rem; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe KS3064 functions identically to the standard KL3064 Bus Terminal. The critical system-level distinction is the physical terminal interface; the KS3064 employs a pluggable terminal system, while the KL3064 utilizes fixed tension clamps. Both share exact software mappings in TwinCAT 2 and TwinCAT 3 systems. If replacing a KL3064, no modifications are required within the PLC configuration.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; font-size: 1.1rem; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this is a single-ended terminal, all 4 input channels share a common internal ground reference linked directly to the system's external ground. If integrating transmitter signals sourced from different, isolated field power supplies, any potential offsets between the power supplies will introduce measurement offset errors. To preserve the 12-bit measurement integrity, ensure that all sensor reference grounds are bonded to a common equipotential earth system.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #1a365d; font-size: 1.1rem; margin-top: 1rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAnalog signals in the 0 to 10 V range are highly susceptible to high-frequency electromagnetic interference from surrounding VFDs and power contacts. It is vital to use shielded twisted-pair cabling. Always ground the signal shield only at the central control cabinet ingress plate rather than terminating the shield to the terminal blocks, to avoid creating ground loop currents across the internal K-bus.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Completely de-energize the PLC master power and isolate all field connections prior to mounting, dismounting, or pulling the pluggable wiring head from the KS3064 housing. Removing the module or terminal strip under active load can corrupt K-bus communication registers, causing unexpected bus master shutdowns and terminal diagnostic faults.\n\u003c\/div\u003e\n\n\u003col style=\"list-style: none; padding: 0; margin-bottom: 1.5rem;\"\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0; font-size: 0.85rem;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eAlign the KS3064 terminal housing with the 35 mm DIN rail (EN 60715) and push firmly until the locking mechanism clicks audibly.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0; font-size: 0.85rem;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSlide the terminal adjacent to the surrounding K-bus modules until the integrated tongue-and-groove side locking tracks slot securely together.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0; font-size: 0.85rem;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eInsert pre-stripped wire conductors (stripped length: 9 to 10 mm) into the pluggable tension-clamp terminal by depressing the spring actuator latch with a flat-head terminal screwdriver.\u003c\/p\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"display: flex; align-items: flex-start;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0; font-size: 0.85rem;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"margin: 0; color: #2d3748;\"\u003eSeat the pluggable terminal connector block firmly into the KS3064 front housing interface until it is fully retained.\u003c\/p\u003e\n  \u003c\/li\u003e\n\u003c\/ol\u003e","brand":"BECKHOFF","offers":[{"title":"Default Title","offer_id":53106528321899,"sku":"KS3064","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/ks3064-fezl3vwq3yp.png?v=1776245288","url":"https:\/\/www.plcprotech.com\/ru\/products\/beckhoff-ks3064-bus-terminal-4-channel-analog-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}