{"product_id":"bently-nevada-133300-01-3500-series-low-voltage-dc-power-input-module","title":"Bently Nevada 133300-01 3500 Series Low Voltage DC Power Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to interface directly with the 3500\/15 power supply system, the \u003cstrong\u003eBently Nevada 133300-01\u003c\/strong\u003e provides regulated low-voltage DC input capabilities to the 3500 machinery protection rack. This rear-mount module accepts \u003cstrong\u003e20 to 30 VDC\u003c\/strong\u003e and conditions the incoming primary power before routing it to the internal backplane. Engineered for high-reliability environments, it is crucial for maintaining continuous machinery monitoring and protecting critical rotating assets from unexpected power interruptions.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSeamless integration with the 3500\/15 Low Voltage DC Power Supply.\u003c\/li\u003e\n  \u003cli\u003eSupports fully redundant power configurations when configured with a secondary rear module.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty terminal block connections designed to withstand industrial vibration.\u003c\/li\u003e\n  \u003cli\u003eBuilt-in overcurrent protection and electromagnetic interference (EMI) filtering.\u003c\/li\u003e\n  \u003cli\u003ePassive cooling design optimized for continuous rack operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eSteam and gas turbine vibration monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator protection setups.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical plant compressor and pump safety racks.\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial power generation and distribution facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e133300-01\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eSeries\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500 Machinery Protection System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eLow Voltage DC Power Input Module (LVDCI)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eInput Voltage Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e20 to 30 VDC\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCompatible Front Supply\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/15 Low Voltage DC Power Supply Module\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eMounting Location\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eRear chassis slot (half-height)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: -0.75rem;\"\u003e-30 to +65 Celsius\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUSA\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.50 kg (3.30 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e24.1 cm x 11.2 cm x 5.1 cm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; width: 40%;\"\u003eTerminal Block Pin\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003ePositive (+)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e+24 VDC Primary Input Power\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eNegative (-)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eDC Return \/ Common\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eChassis Ground (GND)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eSystem \/ Earth Ground connection for shield continuity\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 133300-01 is specifically paired with the low-voltage DC variant of the 3500\/15 power supply. It is physically and electrically incompatible with the high-voltage AC\/DC modules (such as 129767-01 or 120739-01). Always verify the voltage rating of your front-facing 3500\/15 module before hot-swapping or replacing rear input elements.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eIn dual-redundant setups, ensure both low-voltage DC sources originate from independent breakers or power feeds. If both inputs are tied to the same feeder circuit, the system redundancy is effectively bypassed. Avoid routing raw, unfiltered field DC directly to these terminals; use external line conditioning if long cable runs are subject to inductive switching noise.\u003c\/p\u003e\n\n\u003ch4 style=\"color: #2b6cb0; margin-bottom: 0.25rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUse a minimum wire gauge of 14 AWG (2.1 mm2) to prevent excessive voltage drop over runs exceeding 10 meters. Ensure terminal block screws are torqued exactly to 0.56 Nm (5 in-lb) to maintain secure connections under continuous high-frequency machinery vibration.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eDe-energize all primary DC power feeds before installing, removing, or wiring the rear input module. Servicing connections while energized can cause dangerous electrical arcing, localized contact damage, or critical backplane component degradation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eEnsure the main 3500 rack power switch is in the OFF position and the source DC breaker is locked out.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eAlign the 133300-01 module card edges with the card guides in the designated rear half-height slot.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the module firmly forward until its connector mates completely with the backplane connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; min-width: 1.75rem; height: 1.75rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSecure the captive faceplate mounting screws and attach the terminal cover after finalizing field wiring.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668308128107,"sku":"133300-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/133300-01-ry5osi23wfo_6abd5e5b-a071-487b-b77b-e56c673e66b4.jpg?v=1765520743","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-133300-01-3500-series-low-voltage-dc-power-input-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}