{"product_id":"bently-nevada-1900-65a-00-01-03-00-00-1900-series-general-purpose-equipment-monitor","title":"Bently Nevada 1900\/65A-00-01-03-00-00 1900 Series General Purpose Equipment Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eContinuous machinery protection and continuous monitoring find a reliable baseline with the \u003cstrong\u003e1900\/65A-00-01-03-00-00\u003c\/strong\u003e configurable \u003cstrong\u003egeneral purpose equipment monitor\u003c\/strong\u003e. Developed under the \u003cstrong\u003eBently Nevada 1900 Series\u003c\/strong\u003e, this stand-alone monitor is designed to track mechanical parameters such as vibration, temperature, speed, and acceleration on smaller, auxiliary, or general-purpose industrial machinery. This specific configuration is equipped with an integrated, direct-attached local display and housed inside a robust fiberglass weather-proof enclosure rated NEMA 4X\/IP66, ensuring excellent environmental protection in challenging industrial facilities.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFour-channel dynamic input configuration supporting standard industrial accelerometers, velocity sensors, and proximity probes.\u003c\/li\u003e\n  \u003cli\u003eDirectly attached local display module, eliminating the need for complex external cable runs.\u003c\/li\u003e\n  \u003cli\u003eRobust, fiberglass NEMA 4X \/ IP66 weather-proof housing with a window in the door for active status monitoring.\u003c\/li\u003e\n  \u003cli\u003eFour dedicated temperature inputs compatible with RTDs and thermocouples.\u003c\/li\u003e\n  \u003cli\u003eConfigurable relays for machinery emergency trip systems and local alarming.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial ventilation fans, blowers, and air handling units.\u003c\/li\u003e\n  \u003cli\u003eAuxiliary water pumps, cooling pumps, and small air compressors.\u003c\/li\u003e\n  \u003cli\u003eCentrifuges and cooling tower gearboxes.\u003c\/li\u003e\n  \u003cli\u003eGeneral balance-of-plant machinery in power generation, oil \u0026amp; gas, and petrochemical facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Identifier\u003c\/th\u003e\n      \u003cth\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth\u003eSelected Configuration Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e1900\/65A\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBase Model\u003c\/td\u003e\n      \u003ctd\u003eGeneral Purpose Equipment Monitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePower Option\u003c\/td\u003e\n      \u003ctd\u003e18 to 36 Vdc input range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplay Option\u003c\/td\u003e\n      \u003ctd\u003eAttached display (no cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e-03\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMounting Option\u003c\/td\u003e\n      \u003ctd\u003eFiberglass NEMA 4X\/IP66 WP housing with window in door\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eApprovals Option\u003c\/td\u003e\n      \u003ctd\u003eNo hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommunications Option\u003c\/td\u003e\n      \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Range\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\/Model\u003c\/td\u003e\n      \u003ctd\u003e1900\/65A-00-01-03-00-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003e1900 Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply Range\u003c\/td\u003e\n      \u003ctd\u003e18 to 36 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eNEMA 4X \/ IP66 Waterproof and Dust-tight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Material\u003c\/td\u003e\n      \u003ctd\u003eFiberglass with window door\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDisplay Mounting\u003c\/td\u003e\n      \u003ctd\u003eDirectly attached (no cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e19.69 cm x 14.94 cm x 7.44 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e2.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Interface\u003c\/th\u003e\n      \u003cth\u003eFunction Assignment\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Terminals\u003c\/td\u003e\n      \u003ctd\u003eSystem ground and DC power connection (18 to 36 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDynamic Inputs\u003c\/td\u003e\n      \u003ctd\u003eFour channels for proximity, velocity, or acceleration sensors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStatic Inputs\u003c\/td\u003e\n      \u003ctd\u003eFour channels for RTD and thermocouple temperature measurement\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelay Outputs\u003c\/td\u003e\n      \u003ctd\u003eConfigurable dry contact outputs for alarm\/danger trip signaling\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the incoming power source is within the specified 18 to 36 Vdc operating range prior to system energization.\u003c\/li\u003e\n  \u003cli\u003eEnsure all cable entry glands are securely sealed to maintain the structural integrity of the NEMA 4X\/IP66 weatherproof enclosure.\u003c\/li\u003e\n  \u003cli\u003eIsolate low-voltage signal cabling from heavy AC electrical lines and high-interference equipment to prevent electromagnetic coupling.\u003c\/li\u003e\n  \u003cli\u003eMount the enclosure securely on a flat, low-vibration surface or structural column using the integrated mounting brackets.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668297675115,"sku":"1900\/65A-00-01-03-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/1900-65A-00-01-03-00-00-g2dwig0ygn0_a4822287-52cb-4c4c-ada7-95e132fe26a3.jpg?v=1765520453","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-1900-65a-00-01-03-00-00-1900-series-general-purpose-equipment-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}