{"product_id":"bently-nevada-21000-16-05-00-062-03-02-21000-series-proximity-probe-housing-assembly","title":"Bently Nevada 21000-16-05-00-062-03-02 21000 Series Proximity Probe Housing Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eDesigned to provide physical protection and environmental sealing for proximity transducers, the \u003cstrong\u003eBently Nevada 21000-16-05-00-062-03-02\u003c\/strong\u003e is a rugged probe housing assembly configured for industrial machinery monitoring. Built with an anodized aluminum body and a high-grade 304 stainless steel sleeve, this mechanical protective dome shields critical proximity probes from aggressive industrial environments, moisture, and mechanical damage. The integration of specialized cable seals and mounting options ensures seamless deployment on steam turbines, compressors, and high-speed rotating machinery casings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEngineered Protection:\u003c\/strong\u003e Combines a lightweight aluminum housing body with a robust 304 stainless steel sleeve.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized Probe Compatibility:\u003c\/strong\u003e Specially designed for seamless integration with a 3300 XL 8 mm proximity probe.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDirect Mount Configuration:\u003c\/strong\u003e Features a 3\/4-14 NPT mounting thread option with zero standoff adapter requirement.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Cable Entry:\u003c\/strong\u003e Outfitted with multiple grommet options to securely seal varying field cable diameters.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Environmental Seal:\u003c\/strong\u003e Prevents industrial process contaminants and moisture from degrading probe connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cli\u003eIndustrial steam and gas turbine shaft vibration and expansion monitoring.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft alignment and radial displacement measurement.\u003c\/li\u003e\n  \u003cli\u003eHigh-pressure process compressor and pump vibration protection networks.\u003c\/li\u003e\n  \u003cli\u003eCorrosive or high-humidity heavy manufacturing environments demanding mechanical transducers protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eSpecification Parameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eConfiguration Details\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel \/ Article Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e21000-16-05-00-062-03-02\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSeries Name\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e21000 Series Proximity Probe Housing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProbe Option Code\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e16 (Optimized for 3300 XL 8 mm probe)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProbe Cable Length Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e05 (0.5 meter \/ 20 inches)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStandoff Adapter Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e00 (No standoff adapter configured)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProbe Penetration Depth\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e062 (6.2 inches \/ 157.5 mm)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eFittings Package Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e03 (One 3\/4-14 NPT plug; one 3\/4-14 to 1\/2-14 NPT reducer; one cable seal grip with grommets)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCompatible Cable Sizes\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e1\/8 to 3\/16 inch, 1\/4 to 5\/16 inch, and 5\/16 to 3\/8 inch\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Thread Size\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e02 (3\/4-14 NPT)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAnodized Aluminum body with 304 Stainless Steel sleeve\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States (USA)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 kg (4.4 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003ePorts and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eInterface Port\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eThread \/ Fitting Assignment\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; font-weight: bold; color: #1a365d;\"\u003eFunctional Use\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eProcess Connection Port\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3\/4-14 NPT male thread\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDirect casing mounting into the machine housing port.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCable Conduit Entry\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3\/4-14 to 1\/2-14 NPT reducer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eRouting point for secondary flexible or rigid protective conduit.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eExternal Seal Fitting\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eMulti-grommet cable seal grip\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eSecures coaxial cable and prevents process-fluid bypass.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis 21000 housing configuration is tailored for the 3300 XL 8 mm transducer line. If retrofitting an older 7200 series transducer setup, do not attempt to force the probe into the sleeve, as the internal dimensions and shoulder stops differ. Verify sleeve inner diameter clearance prior to insertion.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOperating in environments with highly corrosive acidic gases can accelerate galvanic corrosion between the aluminum body and the stainless steel sleeve if moisture pools around the threads. In such installations, ensure thread lubricants with active anti-corrosion inhibitors are applied uniformly during assembly.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways insert the probe and route its integrated 0.5-meter cable through the sleeve and cable grip BEFORE securing the housing into the machine casing. Spinning the housing with the probe pre-installed and wired will twist the coaxial cable, leading to micro-fractures in the conductor shield and subsequent signal degradation.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Verify the machinery is completely de-energized, depressurized, and cooled to ambient temperature before installing or adjusting the probe housing. Physical ejection under fluid or gas pressure can cause severe personal injury or catastrophic transducer destruction.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 30px; height: 30px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 15px; font-weight: bold;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eInspect the machinery mounting port and clear away any residual thread compounds, oxidation, or burrs from the 3\/4-14 NPT interface.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 30px; height: 30px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 15px; font-weight: bold;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eInsert the 3300 XL probe into the sleeve and run the 0.5-meter coaxial cable carefully through the internal passage. Ensure the probe is securely seated at the base.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 30px; height: 30px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 15px; font-weight: bold;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eApply an appropriate industrial thread sealant to the 3\/4-14 NPT mounting threads, thread the housing into the machine case, and torque to OEM specifications.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"display: flex; justify-content: center; align-items: center; min-width: 30px; height: 30px; border-radius: 50%; background-color: #2b6cb0; color: #ffffff; margin-right: 15px; font-weight: bold;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748; padding-top: 3px;\"\u003eSelect the matching grommet size from the Option 03 pack based on your cable outer diameter. Assemble the cable seal grip to seal the exit port completely.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668301312363,"sku":"21000-16-05-00-062-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/21000-16-05-00-062-03-02-isucj53bymn_f35c9da9-63ba-450a-bcf8-0eedc4077277.jpg?v=1765520545","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-21000-16-05-00-062-03-02-21000-series-proximity-probe-housing-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}