{"product_id":"bently-nevada-330101-00-80-20-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-80-20-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eProviding critical machinery protection, the \u003cstrong\u003eBently Nevada 330101-00-80-20-02-05\u003c\/strong\u003e operates as a high-precision \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e designed for non-contact shaft vibration and axial position measurements. As a core component of the 3300 XL 8 mm Proximity Transducer System, this probe utilizes eddy-current technology to deliver exceptionally accurate displacement tracking in demanding environments. This specific configuration features a fully threaded 8.0-inch case length with 0.0 inches of unthreaded length, making it ideal for deep-insertion flush-mount setups inside bearing housings and machinery casings where unthreaded standoffs are not required. Equipped with a standard 2.0-meter coaxial cable terminated in a miniature ClickLoc connector, this unarmored probe pairs seamlessly with 3300 XL extension cables and Proximitor sensors.\u003c\/p\u003e\n\u003cp\u003eUnlike alternative variants in the same product line that feature protective armor or metric threads, this unarmored 3\/8-24 UNF threaded configuration provides standard routing flexibility through narrow conduits and machine interiors. Certified with comprehensive CSA, ATEX, and IECEx hazardous area approvals (-05 option), this probe is engineered for continuous operation in explosive atmospheres, establishing it as an industry standard for monitoring steam turbines, gas turbines, compressors, pumps, and other high-speed rotating assets.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-resolution 8 mm tip diameter optimized for non-contact eddy-current displacement and vibration tracking\u003c\/li\u003e\n  \u003cli\u003eFully threaded 8.0-inch stainless steel case (3\/8-24 UNF-2A) provides robust structural mounting with zero unthreaded standoff\u003c\/li\u003e\n  \u003cli\u003e2.0-meter standard coaxial cable ensures stable, low-noise signal transmission for reliable diagnostics\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector delivers a secure, low-loss electrical connection while simplifying install procedures\u003c\/li\u003e\n  \u003cli\u003ePremium polyphenylene sulfide (PPS) tip molding protects probe coil from chemical degradation, moisture, and high temperatures\u003c\/li\u003e\n  \u003cli\u003eExplosion-proof certification under CSA, ATEX, and IECEx standards for deployment in hazardous industrial zones\u003c\/li\u003e\n  \u003cli\u003eUniversal compatibility with Bently Nevada 3300 XL extension cables, 330180 series Proximitor sensors, and 3500 monitoring racks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis 3300 XL proximity probe configuration is designed for continuous machinery diagnostics and plant-wide asset protection across several industries, including power generation, oil and gas, and chemical processing. Common usage scenarios include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration monitoring on steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eAxial thrust and shaft displacement tracking on high-pressure compressors\u003c\/li\u003e\n  \u003cli\u003eRotor movement and thermal expansion measurement in industrial pumps\u003c\/li\u003e\n  \u003cli\u003eShaft centerline tracking to diagnose sleeve bearing wear, misalignment, and instability\u003c\/li\u003e\n  \u003cli\u003ePermanent vibration monitoring on critical rotating machinery operating in hazardous or explosive environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-80-20-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e80\u003c\/td\u003e\n      \u003ctd\u003e8.0 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 meters (6.6 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330101-00-80-20-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eDisplacement \/ proximity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Principle\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEddy current\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.0 in (203.2 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 m (6.6 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard coaxial cable (non-armored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils), starting at approx. 0.25 mm (10 mils) to 2.25 mm (90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/-5% typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal Probe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.88 ohms +\/-0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Cable)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal built into probe tip to seal differential pressure\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 3% change in Average Scale Factor (ASF) up to 56 days at 93% humidity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAdherence to proper mechanical and electrical guidelines ensures optimal transducer signal and mechanical safety:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e Mount with a physical gap that aligns with your specific calibration. The nominal recommended gap setting for radial vibration monitoring is approximately 1.27 mm (50 mils), which corresponds to a -9 Vdc output on a calibrated Proximitor sensor.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e The maximum thread engagement length for this 3\/8-24 UNF threaded probe case is 0.563 inches (14.3 mm). Do not force past this depth to prevent binding or physical casing damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Ensure the 2.0-meter probe cable is routed safely through conduit, away from high-temperature areas and power cables that generate excessive electromagnetic noise. Maintain proper shielding and grounding practices.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Connection:\u003c\/strong\u003e Hand-tighten the gold coaxial ClickLoc connectors. When connecting with non-XL stainless steel coaxial fittings, secure them finger-tight plus an additional 1\/8 turn using pliers. Do not over-torque.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eDesigned for continuous machinery diagnostics globally, this proximity probe conforms to the following standards:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Intrinsically safe for use in Zone 0, Zone 1, and Zone 2 hazardous areas (Ex ia IIC T5...T1 Ga, Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Approved for Class I, Division 1 and 2, Groups A, B, C, and D hazardous atmospheres\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Fully compliant with European environmental restriction of hazardous substances\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666741981547,"sku":"330101-00-80-20-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-80-20-02-05-3300-xl-8-mm-proximity-probes-u0i5zv124oa_0a00d5a9-0b51-4589-8435-c0b769c8b253.jpg?v=1765446884","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330101-00-80-20-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}