{"product_id":"bently-nevada-330102-00-60-05-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330102-00-60-05-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (fully threaded), Option 60 (6.0 in overall case length), and Option 05 (0.5 m total length) specify this armored 3300 XL 8 mm proximity probe configuration — \u003cstrong\u003e330102-00-60-05-02-05\u003c\/strong\u003e. Designed for high-integrity eddy-current displacement monitoring, this probe integrates a flexible AISI 302\/304 stainless steel protective armor with an outer FEP jacket directly over the FEP triaxial probe cable. This heavy-duty mechanical sleeve protects the signal lead from sharp edges, mechanical impacts, and environmental contaminants commonly found in heavy rotating machinery housings.\u003c\/p\u003e\n\n\u003cp\u003eThe probe case features a 3\/8-24 UNF-2A thread configuration with a 6.0 in total case length and no unthreaded portion. The probe tip is made from polyphenylene sulfide (PPS) plastic and houses the inductive eddy-current sensor coil, which measures both static axial position and dynamic shaft vibration. It terminates in a gold-plated miniature coaxial ClickLoc connector (Option 02) and complies with hazardous area installation requirements under Option 05, making it suitable for hazardous area classification zones.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProtective flexible stainless steel armor (AISI 302\/304) with an FEP outer jacket to guard the signal path against abrasion and mechanical stresses.\u003c\/li\u003e\n  \u003cli\u003eFully threaded 3\/8-24 UNF-2A steel body (Option 00) with a 6.0 in case length (Option 60) for long-reach deep-bore machinery installations.\u003c\/li\u003e\n  \u003cli\u003e0.5 meter (1.6 feet) total probe length (Option 05) designed to be combined with standard 3300 XL extension cables.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connector (Option 02) providing a secure gold-plated connection to standard extension cables without requiring a connector protector.\u003c\/li\u003e\n  \u003cli\u003eAgency approval package Option 05, certifying compliance with CSA, ATEX, and IECEx requirements for hazardous area classifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used across power generation, petrochemical, oil and gas, and wastewater industries. Primary applications include shaft vibration and axial position measurement on high-speed rotating machinery, as well as speed detection and Keyphasor reference measurements on fluid-film bearing systems. It is typically deployed on turbines, compressors, gearboxes, pumps, and fans where the cable run requires enhanced physical shielding.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning \/ Configuration\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330102\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, 3\/8-24 UNF thread, with protective armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60\u003c\/td\u003e\n      \u003ctd\u003e6.0 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (no connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx approvals for hazardous areas\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330102-00-60-05-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e152.4 mm (6.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 mm (0.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 or 304 SST with FEP outer jacket\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Diameter (Armored)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.67 mm (0.302 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Ferrule Max Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10.2 mm (0.40 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.45 +\/- 0.50 Ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength (Max Rated)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) case to lead, 270 N (60 lbf) lead to connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.5 N-m (66 in-lbf) recommended, 22.6 N-m (200 in-lbf) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Seal Sealing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e180 mm x 180 mm x 45 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.18 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection \/ Part\u003c\/th\u003e\n      \u003cth\u003eSpecification \/ Signal Interface\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector (gold-plated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCenter Pin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRF Dynamic signal path\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Shield\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCommon ground \/ return path\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLocking Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTactile \"click\" mechanical locking mating system\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eDo not exceed the recommended installation torque of 7.5 N-m (66 in-lbf) on the 3\/8-24 UNF-2A thread to avoid damaging the sensor case.\u003c\/li\u003e\n  \u003cli\u003eEnsure the minimum bend radius of 25.4 mm (1.0 in) is maintained for the armored cable path during installation.\u003c\/li\u003e\n  \u003cli\u003eProvide a physical side-clearance of at least three probe tip diameters (24.0 mm or 0.94 in) between the probe tip and surrounding metal to prevent side-loading calibration errors.\u003c\/li\u003e\n  \u003cli\u003eIf installing in pressure-retaining housings, implement proper outer gland seals, and note that standard probes are not pre-tested for high-pressure sealing before shipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHazardous Area Certifications\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eClassifications\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIntrinsically Safe (Ex ia IIC) and Non-incendive \/ Non-sparking (Ex nA IIC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCE Compliance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666611335531,"sku":"330102-00-60-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330102-00-60-05-02-05-3300-xl-8-mm-proximity-probes-4vu54mryqui_48ca20fd-2939-4b65-af01-c34057b68722.jpg?v=1765444144","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330102-00-60-05-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}