{"product_id":"bently-nevada-330103-00-02-20-02-05-3300-xl-8-mm-proximity-probe","title":"Датчик приближения Bently Nevada 330103-00-02-20-02-05 3300 XL 8 мм","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0 mm unthreaded length) and Option 02 (20 mm overall case length) specify this metric M10 x 1 threaded probe configuration — \u003cstrong\u003e330103-00-02-20-02-05\u003c\/strong\u003e. This 3300 XL 8 mm proximity probe features a 2.0-meter standard cable (Option C: 20) with a miniature coaxial ClickLoc connector (Option D: 02) and is approved for hazardous environments under CSA, ATEX, and IECEx certifications (Option E: 05). Designed without mechanical armor, the probe operates as part of an eddy-current transducer system to measure shaft vibration, position, and speed on rotating machinery. It interfaces directly with a matching 3300 XL Proximitor sensor and standard extension cable.\u003c\/p\u003e\n\u003cp\u003eUnlike variants configured with armored cabling (such as the 330104 series) or those featuring connector protectors (Option D: 01), this configuration utilizes an unarmored, lightweight coaxial line and a standard ClickLoc connector. The M10 x 1 metric thread is fully threaded along its entire 20 mm case length because there is no unthreaded section (Option A: 00), allowing for direct, low-profile mounting in machinery casings where space is limited.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFully Threaded Case\u003c\/strong\u003e: Features an M10 x 1 metric thread with 20 mm of case length and 0 mm of unthreaded length, enabling direct mounting in shallow machine casings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnarmored 2.0-Meter Cable\u003c\/strong\u003e: Equipped with a 2.0 m unarmored coaxial cable that provides reduced weight and flexibility during installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eClickLoc Coaxial Connector\u003c\/strong\u003e: Utilizes a gold-plated ClickLoc connector to ensure low-resistance electrical connections without the bulk of integrated connector protectors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approved\u003c\/strong\u003e: Certified for hazardous areas (Option 05) with CSA, ATEX, and IECEx intrinsic safety and non-incendive approvals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePPS Probe Tip\u003c\/strong\u003e: Molded polyphenylene sulfide (PPS) tip ensures robust resistance against high temperatures and corrosive environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis probe configuration is used on rotating machinery across power generation, petrochemical, and water treatment industries. Specific applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft radial vibration measurement on steam turbines and compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial shaft position tracking on industrial gas turbines and generators.\u003c\/li\u003e\n  \u003cli\u003eKeyphasor speed and phase reference monitoring on machinery train shafts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-00-02-20-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e20 mm overall case length (metric thread)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e20\u003c\/td\u003e\n      \u003ctd\u003e2.0 meters (6.6 feet) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard FEP-insulated coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx approvals for hazardous areas\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOptional Suffix (if appended)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-CN\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI, CCC approvals and markings)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth\u003eValue \/ Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e330103-00-02-20-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8.0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Thread Size\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCase Length\u003c\/td\u003e\n      \u003ctd\u003e20 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd\u003e2.0 m (6.6 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, FEP insulated, unarmored\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature gold-plated coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal DC Resistance\u003c\/td\u003e\n      \u003ctd\u003e7.88 ohms +\/- 0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Rated Case Torque\u003c\/td\u003e\n      \u003ctd\u003e22.6 N-m (200 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Case Torque\u003c\/td\u003e\n      \u003ctd\u003e7.5 N-m (66 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Pressure Seal Rating\u003c\/td\u003e\n      \u003ctd\u003eDesigned to seal differential pressure between tip and case (Viton O-ring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e180 mm x 180 mm x 40 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.36 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap\u003c\/strong\u003e: Gap the probe target at the appropriate voltage using a digital multimeter connected to the Proximitor sensor output (typically -10.0 Vdc for the middle of the linear range).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Torque\u003c\/strong\u003e: When mounting the M10 x 1 thread probe case, do not exceed the maximum rated torque of 22.6 N-m (200 in-lbf). Recommended installation torque is 7.5 N-m (66 in-lbf).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius\u003c\/strong\u003e: Ensure the unarmored FEP-insulated probe cable maintains a minimum bend radius of 25.4 mm (1.0 in) to prevent internal coaxial shielding damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Handling\u003c\/strong\u003e: Connectors must be kept clean and dry. Finger-tighten the ClickLoc coaxial connectors until they click to secure the connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA\u003c\/strong\u003e: Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\u003c\/strong\u003e: II 1 G Ex ia IIC T5...T1 Ga; II 3 G Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx\u003c\/strong\u003e: Ex ia IIC T5...T1 Ga; Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e: SIL 2 certified (HFT = 0), SIL 3 capable (HFT = 1)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS\u003c\/strong\u003e: Fully compliant with EU RoHS Directive 2011\/65\/EU and China RoHS standards.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCCC\/NEPSI (with Optional -CN Suffix)\u003c\/strong\u003e: Approved for China hazardous area installations when ordered with the -CN suffix.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666768064875,"sku":"330103-00-02-20-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-02-20-02-05-3300-xl-8mm-proximity-probes-2q1u4sbptvd_ba9e231d-92bb-4017-ad0d-85e5a896c7c1.jpg?v=1765447240","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330103-00-02-20-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}