{"product_id":"bently-nevada-330130-070-02-00-3300-xl-8mm-extension-cable","title":"Bently Nevada 330130-070-02-00 3300 XL 8mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eOptimizing the signal transmission path within machinery protection systems, the \u003cstrong\u003eBently Nevada 330130-070-02-00\u003c\/strong\u003e acts as a high-fidelity electrical link between proximity probes and sensor systems. This industrial-grade coaxial extension cable is engineered specifically for integration with the \u003cstrong\u003e3300 XL 8mm\u003c\/strong\u003e proximity sensor family, ensuring precise, low-loss transmission of critical eddy current displacement signals over long run distances.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Electrical Length:\u003c\/strong\u003e Calibrated specifically to 7.0 meters (22.9 feet) to preserve the exact impedance metrics of the complete transducer system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e Features Option 02 integrated connector protectors, safeguarding delicate coaxial junctions from environmental contaminants.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNoise Mitigation:\u003c\/strong\u003e Advanced shielding design protects the dynamic signal against electromagnetic interference (EMI) and radio frequency interference (RFI) in high-voltage industrial zones.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Mechanical Integrity:\u003c\/strong\u003e High-durability sheath minimizes the risk of physical wear, stretching, or signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eContinuous shaft vibration and axial position tracking on steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eCompressor, pump, and electric motor bearings condition monitoring.\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial rotating machinery subject to high thermal and mechanical stress.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0; text-align: left;\"\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 8px; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e330130-070-02-00\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCompatible Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e3300 XL 8mm Proximity Transducer System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003e7.0 meters (22.9 feet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCable Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eStandard cable with connector protectors (Option 02)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eAgency Approval\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eNot required (Option 00)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 8px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 8px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 3.0 kg;\"\u003e3.0 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch3\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis 7.0-meter extension cable is designed to match standard system lengths (e.g., matching a 1.0-meter probe to achieve an 8.0-meter total system, or a 2.0-meter probe for a 9.0-meter system configuration). Substituting a cable of incorrect length or series will introduce impedance mismatches, distorting the output calibration of the proximitor sensor.\u003c\/p\u003e\n\n\u003ch3\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways maintain minimum bend radius requirements during installation. Subjecting the coaxial cable to sharp angles can pinch the dielectric core, causing internal reflections and parasitic signal attenuation that may lead to false vibration readings or unnecessary control system trips.\u003c\/p\u003e\n\n\u003ch3\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eUtilize the integrated connector protectors during field connection to isolate the coaxial interface from aggressive lubricating oils, humidity, and high-frequency electrical noise. Ensure connections are hand-tightened to correct torque specifications using specialized coaxial wrenches to avoid damaging the internal threads.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to beginning installation, ensure the respective vibration monitoring rack or proximitor module is de-energized. Do not route coaxial extension cables parallel to high-power motor drive cables or high-voltage lines, as inductive cross-coupling can cause severe signal distortion.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eExamine both male and female coaxial terminal pins to verify they are free of debris, oxidation, and moisture.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eAlign the connectors carefully and secure the click-lock mechanism. Slide the integrated connector protector fully over the completed connection.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; align-items: flex-start; margin-bottom: 1rem;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eSecure the physical cable along the cable tray or conduit, ensuring adequate support and avoidance of potential sharp edges.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668306555243,"sku":"330130-070-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-070-02-00-1ovvipmgy2v_5c8b12dd-a1bb-4ea3-87f7-7b8d3092f600.jpg?v=1765520680","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330130-070-02-00-3300-xl-8mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}