{"product_id":"bently-nevada-330709-000-040-50-02-00-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330709-000-040-50-02-00 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 000 (0 mm unthreaded length) and Option 02 (ClickLoc connector, standard cable without protector) specify this metric 3300 XL 11 mm proximity probe configuration — \u003cstrong\u003e330709-000-040-50-02-00\u003c\/strong\u003e. Featuring an unarmored M16 x 1.5 threaded stainless steel body, this probe provides a 4.0 mm (160 mil) linear measurement range when paired with a matching 5.0-meter 3300 XL Proximitor Sensor and extension cable. The 5.0-meter total length option allows direct connection to a 5.0-meter Proximitor without requiring a separate extension cable, simplifying installation in space-constrained layouts.\u003c\/p\u003e\n\u003cp\u003eUnlike variants configured with stainless steel armor or protective connector boots, this unarmored configuration offers maximum flexibility for standard conduit runs. It is engineered for non-contacting shaft vibration, axial position, and differential expansion measurements on rotating machinery such as turbines, compressors, and pumps. This specific option combination is designated for non-hazardous environments where formal agency approval is not required.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 000 unthreaded design provides a fully threaded M16 x 1.5 probe body for secure mounting depth adjustment.\u003c\/li\u003e\n\u003cli\u003eOption 040 specifies a compact 40 mm overall case length ideal for standard mounting brackets.\u003c\/li\u003e\n\u003cli\u003eOption 50 provides a 5.0 m (16.4 ft) total probe length, optimized for 5-meter system configurations.\u003c\/li\u003e\n\u003cli\u003eOption 02 ClickLoc miniature coaxial connector delivers secure, vibration-resistant connections.\u003c\/li\u003e\n\u003cli\u003eUnarmored FEP insulated triaxial cable offers excellent chemical resistance and high flexibility.\u003c\/li\u003e\n\u003cli\u003eLarge 11 mm tip diameter extends the linear range compared to standard 8 mm transducer systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis 11 mm proximity probe is utilized in heavy industrial rotating machinery monitoring systems. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam turbine ramp differential expansion monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor and turbine axial (thrust) position measurements\u003c\/li\u003e\n\u003cli\u003eShaft radial vibration monitoring on fluid-film bearing machines\u003c\/li\u003e\n\u003cli\u003eTachometer, zero-speed, and phase reference (Keyphasor) signal generation\u003c\/li\u003e\n\u003cli\u003eReciprocating compressor rod drop and rod position measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330709-000-040-50-02-00\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Probe, M16 x 1.5 thread, without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e000\u003c\/td\u003e\n\u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e40 mm case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo approvals required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330709-000-040-50-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM16 x 1.5 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout armor (unarmored)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial, FEP insulated, standard jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.0 mm (160 mils), starting at approximately 0.5 mm (20 mils) from target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.94 V\/mm (100 mV\/mil) +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 8 kHz (+0, -3 dB typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe dc Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.2 +\/-0.8 ohms (from center conductor to outer conductor for 5.0 m probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330 N (75 lb) max rated probe case to probe lead; 270 N (60 lb) at connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63.3 N-m (560 in-lb) maximum rated, 21.1 N-m (187 in-lb) recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 degC for probe and cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the mounting bracket is tapped to receive the M16 x 1.5 metric thread.\u003c\/li\u003e\n\u003cli\u003eVerify the probe gap is set to the recommended 2.5 mm (100 mils) using a feeler gauge or by measuring the DC voltage output of the Proximitor (typically -10 Vdc at middle gap).\u003c\/li\u003e\n\u003cli\u003eObserve the maximum torque rating of 63.3 N-m (560 in-lb) during installation to prevent damage to the threaded case.\u003c\/li\u003e\n\u003cli\u003eRoute the coaxial cable through protective metal conduit to protect the FEP jacket from abrasive contact or mechanical pinch points.\u003c\/li\u003e\n\u003cli\u003eMaintain the minimum cable bend radius of 25.4 mm (1.0 in) to preserve signal integrity and coaxial shielding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003eCE Mark (when installed with appropriate 3300 XL Proximitor Sensor and mounting)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850574699,"sku":"330709-000-040-50-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330709-000-040-50-02-00-reverse-mount-probe-m4fjxw4eywt_896ccecc-ad56-4928-87f5-53a11811323b.jpg?v=1765449034","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330709-000-040-50-02-00-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}