{"product_id":"bently-nevada-330851-02-000-60-10-00-05-3300-xl-25-mm-proximity-probe","title":"Bently Nevada 330851-02-000-60-10-00-05 3300 XL 25 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThreaded M30x2 metric steel case (Option 02) with 0.0 mm unthreaded length (Option 000) and 60 mm overall case length (Option 60) defines the configuration of the \u003cstrong\u003e330851-02-000-60-10-00-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL 25 mm Proximity Probe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration incorporates a 1.0 m (3.3 feet) unarmored FluidLoc cable (Option 10-00) and includes multiple agency hazardous area approvals (Option 05) such as CSA, ATEX, and IECEx. Unlike variants featuring custom unthreaded sections, a longer case, or stainless steel armor protection, this probe provides a direct-exit unarmored configuration ideal for installation environments with pre-existing protective conduit. It is typically used for large-target non-contact eddy-current measurements such as steam turbine differential expansion, large shaft axial position, and reciprocating compressor rod-drop monitoring.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM30x2 metric threaded case option for direct installation into threaded machine housings.\u003c\/li\u003e\n  \u003cli\u003eUnarmored 75 ohm triaxial FluidLoc probe cable with a 1.0 m total length.\u003c\/li\u003e\n  \u003cli\u003eMultiple agency approvals including CSA, ATEX, and IECEx for hazardous area installations.\u003c\/li\u003e\n  \u003cli\u003eViton O-ring and compression seal structure to prevent fluid leakage through the case.\u003c\/li\u003e\n  \u003cli\u003ePolyetheretherketone probe tip material for compatibility with harsh industrial fluids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam turbine differential expansion monitoring on mid-size to large machine trains.\u003c\/li\u003e\n  \u003cli\u003eLarge-target shaft axial displacement and rotor position measurements.\u003c\/li\u003e\n  \u003cli\u003eRod-drop monitoring in reciprocating compressor installations.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection systems requiring large-target non-contact eddy-current sensing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eConfiguration Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330851\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Probe Case Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eM30x2 thread metric case type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0.0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60\u003c\/td\u003e\n      \u003ctd\u003e60 mm overall case length (metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD: Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 metre (3.3 feet) total cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE: Armor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo SST Armor (unarmored FluidLoc cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eF: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330851-02-000-60-10-00-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 25 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e12.7 mm (500 mils), beginning at approximately 0.63 mm (25 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.787 V\/mm (20 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.31 mm (+\/-12 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 2.7 kHz: +0, -3 dB typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e61 mm (2.4 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyetheretherketone (PEEK)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, perfluoroalkoxyethylene (PFA) insulated FluidLoc cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Probe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 m (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNone (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-35 degC to +200 degC (-31 degF to +392 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShort-Term Temperature Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+250 degC (482 degF) maximum for less than 24 hours\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Thread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM30x2 metric threaded\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain a minimum target diameter of 61 mm (2.4 in) of flat steel to preserve the linear calibration range.\u003c\/li\u003e\n  \u003cli\u003eEnsure correct probe gapping of approximately -1.5 Vdc to -11.5 Vdc (0.63 mm to 13.33 mm) within the linear range.\u003c\/li\u003e\n  \u003cli\u003eTighten the M30x2 metric threaded case to a recommended torque of 68 N-m (50 ft-lb) with a maximum limit of 163 N-m (120 ft-lb).\u003c\/li\u003e\n  \u003cli\u003eProtect the coaxial cable connectors using fluorosilicone connector protectors to prevent moisture and oil ingress.\u003c\/li\u003e\n  \u003cli\u003eConnect the probe to a compatible 3300 XL 25 mm extension cable and Proximitor sensor for a total system length of 5.0 m or 9.0 m as required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCE Mark compliant\u003c\/li\u003e\n  \u003cli\u003eCSA, ATEX, and IECEx approvals for hazardous areas (Option 05)\u003c\/li\u003e\n  \u003cli\u003eIntrinsically Safe (Ex ia IIC T5...T1 Ga) when installed with intrinsically safe barriers or galvanic isolators\u003c\/li\u003e\n  \u003cli\u003eNon-Incendive (Ex nA IIC T5...T1 Gc) and (Ex ec IIC T5...T1 Gc) for Zone 2 hazardous areas\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666642956651,"sku":"330851-02-000-60-10-00-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330851-02-000-60-10-00-05-3300-xl-25-mm-proximity-probe-aaaqjedwgsb_7225db77-eda2-410d-ab15-191cb0c54956.jpg?v=1765444576","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330851-02-000-60-10-00-05-3300-xl-25-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}