{"product_id":"bently-nevada-330881-28-00-145-00-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-00-145-00-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals), Option 00 (no standoff adapter), and Option 145 (145 mm penetration length) specify this metric \u003cstrong\u003eBently Nevada 330881-28-00-145-00-02 PROXPAC XL Proximity Transducer\u003c\/strong\u003e configuration.\u003c\/p\u003e\n\n\u003cp\u003eThis self-contained transducer assembly integrates the proximity probe and the Proximitor sensor into a single, compact housing. This design eliminates the need for intermediate extension cables and external Proximitor housings, allowing field wiring to connect directly from the machinery monitors to the terminal block inside the housing lid. By housing both elements in glass-reinforced, UV-resistant Polyphenylene Sulfide (PPS) thermoplastic, the system provides physical protection and electrostatic dissipation in severe industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegrated 3300 XL 8 mm proximity probe and Proximitor sensor housed in a single Polyphenylene Sulfide (PPS) thermoplastic assembly.\u003c\/li\u003e\n  \u003cli\u003eOption 28 probe and approvals configuration including standard multiple hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003e145 mm metric probe penetration length with no standoff adapter (Option 00).\u003c\/li\u003e\n  \u003cli\u003eOption 02 mounting thread with 3\/4-14 NPT outer sleeve threads.\u003c\/li\u003e\n  \u003cli\u003eIP66 and Type 4X rated housing constructed of conductive, glass-reinforced PPS to dissipate electrostatic charges.\u003c\/li\u003e\n  \u003cli\u003eDirect field-terminal connections eliminating the need for intermediate extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration monitoring on large rotating machinery shafts.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position measurements in steam turbines, gas turbines, and compressors.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection in severe environments requiring IP66 or Type 4X housing protection.\u003c\/li\u003e\n  \u003cli\u003eHigh-exposure areas where electrostatic discharge or chemical resistance is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-00-145-00-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Probe and Approvals Option\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Standoff Adapter Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Probe Penetration Option\u003c\/td\u003e\n      \u003ctd\u003e145\u003c\/td\u003e\n      \u003ctd\u003e145 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Fittings Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Mounting Thread Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT mounting thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ SKU\u003c\/td\u003e\n      \u003ctd\u003e330881-28-00-145-00-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Sensor\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe with 1 m integrated triaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSignal Output\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Supply\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc at 12 mA maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Material\u003c\/td\u003e\n      \u003ctd\u003eGlass-reinforced, UV-resistant Polyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSleeve Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Sleeve Thread\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFittings\u003c\/td\u003e\n      \u003ctd\u003eNone (includes two plugs and two washers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer Operating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +85 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHousing Lid Label Material\u003c\/td\u003e\n      \u003ctd\u003eGloss radiant white polyester\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eTerminal Pin\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCOM\u003c\/td\u003e\n      \u003ctd\u003eCommon (Transducer Return)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOUT\u003c\/td\u003e\n      \u003ctd\u003eOutput Signal (Dynamic Voltage)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVTG\u003c\/td\u003e\n      \u003ctd\u003eSupply Voltage (-17.5 Vdc to -26 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the outer sleeve is properly torqued into the machinery casing. The recommended torque for the probe sleeve locknut is 39.3 N-m (350 in-lb). The retaining nut should be torqued to 29.5 N-m (260 in-lb). When deploying in hazardous locations, verify local grounding requirements; the conductive fibers in the PPS housing must be correctly integrated with the local safety grounding system. Field terminal wires must be connected securely using terminal screws inside the lid, minimizing exposed conductors.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe integrated probe and Proximitor components comply with standard international electrical and industrial regulations. Key certifications include ATEX\/IECEx hazardous area approvals (Ex ia IIC T4\/T5 Ga, Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc), CSA Class I, Zone 0, AEx\/Ex ia IIC T4\/T5 Ga, and European CE marking for Electromagnetic Compatibility (EMC Directive 2014\/30\/EU, EN 61000-6-2, EN 61000-6-4) and RoHS (Directive 2011\/65\/EU).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666742604139,"sku":"330881-28-00-145-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-00-145-00-02-proxpac-xl-proximity-transducer-4usxc2siqfi_14b0e31a-3ff6-4d27-9df8-53ac7aeb9ddd.jpg?v=1765446905","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330881-28-00-145-00-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}