{"product_id":"bently-nevada-330901-00-65-05-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-65-05-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330901-00-65-05-02-05\u003c\/strong\u003e specifies this 3300 NSv proximity probe configuration featuring a 1\/4-28 UNF thread without armor, 0.0 inches of unthreaded body, a 6.5-inch case length, and a 0.5-meter total cable length. This non-contacting displacement probe uses an eddy-current measurement field to monitor shaft vibration and axial position in critical industrial machinery. This configuration is built with a standard coaxial cable terminating in a miniature male ClickLoc connector and includes international multiple approvals (CSA, ATEX, IECEx) for hazardous areas.\u003c\/p\u003e\n\u003cp\u003eThe 3300 NSv transducer system is applied in tight-clearance situations where target geometries are extremely small or clearances are restricted, allowing installation on smaller machinery shafts that cannot accommodate standard 8 mm probes. While standard probes require larger target areas, the 3300 NSv series operates with a shaft diameter as small as 8.9 mm (0.35 inches), providing precise proximity measurement for aeroderivative gas turbines, centrifugal compressors, and other high-speed rotating equipment.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eStandard mount 1\/4-28 UNF threaded case without protective armor\u003c\/li\u003e\n  \u003cli\u003e0.0 inches unthreaded length with a 6.5-inch overall case length\u003c\/li\u003e\n  \u003cli\u003e0.5 meters (20 inches) integrated 75-ohm coaxial cable length\u003c\/li\u003e\n  \u003cli\u003eMiniature male coaxial ClickLoc connector with standard cable type\u003c\/li\u003e\n  \u003cli\u003eMultiple hazardous area agency approvals (Option 05)\u003c\/li\u003e\n  \u003cli\u003e1.5 mm (60 mils) linear range beginning at 0.25 mm (10 mils) from the target\u003c\/li\u003e\n  \u003cli\u003eScale factor of 7.87 V\/mm (200 mV\/mil) for compatibility with standard monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurement on machinery with limited target clearances\u003c\/li\u003e\n  \u003cli\u003eHigh-speed industrial turbomachinery and aeroderivative gas turbines\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressors, pumps, and fans with small-bore shaft dimensions\u003c\/li\u003e\n  \u003cli\u003eShaft diameters from 8.9 mm (0.35 inches) up to 30 mm (1.2 inches)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eSegment Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 inches unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e65\u003c\/td\u003e\n      \u003ctd\u003e6.5 inches case length (Order in 0.1-inch increments)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meters (20 inches) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector \u0026amp; Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-65-05-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e6.5 in (165 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.5 m (20 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm standard coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils) starting at 0.25 mm (10 mils) gap\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePressure Seal Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring pressure seal (sustained exposure below -34 degC can cause seal wear)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Minimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e13 mm (0.5 in) diameter (8.9 mm \/ 0.35 in absolute minimum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) case-to-lead or connector-to-connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Recommended Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.1 N-m (45 in-lb) recommended, 7.3 N-m (65 in-lb) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Component\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoaxial Center Conductor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eTransmits high-frequency RF signal from the Proximitor to the probe tip\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCoaxial Outer Shield\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eServes as the common return path and provides shielding against EMI\/RFI\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eClickLoc Miniature Male Connector\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eProvides a secure, quick-locking connection to the female end of the extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Adjustment:\u003c\/strong\u003e Maintain a recommended gap setting of 1.0 mm (40 mils) during installation. This corresponds to approximately -9 Vdc at the Proximitor Sensor output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCross-Talk Prevention:\u003c\/strong\u003e If installing dual probes, maintain a minimum tip separation of 25 mm (1.0 in) for axial orientation or 23 mm (0.9 in) for radial\/X-Y orientation to avoid electromagnetic cross-talk.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Hole Specs:\u003c\/strong\u003e When drilling and tapping mounting holes for this 1\/4-28 UNF threaded probe, a #3 or larger tap drill is recommended.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e Tighten standard mount 1\/4-28 UNF probe cases to a recommended torque of 5.1 N-m (45 in-lb). Do not exceed the maximum rated torque of 7.3 N-m (65 in-lb).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals (Option 05)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMultiple global approvals including CSA, ATEX, and IECEx\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIntrinsic Safety (Ex ia)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx ia IIC T5...T1 Ga \/ Ex ia IIIC T90 degC...T280 degC Dc (Class I, Div 1, Groups A, B, C, D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNon-Sparking (Ex nA \/ Ex ec)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEx nA IIC T5...T1 Gc \/ Ex ec IIC T5...T1 Gc (Class I, Div 2, Groups A, B, C, D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eElectromagnetic Compatibility (EMC)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCE compliant for RFI\/EMI immunity when paired with matching 3300 XL NSv Proximitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666631094635,"sku":"330901-00-65-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-65-05-02-05-3300-nsv-proximity-probes-jg31fpqt2bl_d74d1fb6-a5c9-4a8e-b16a-1c5faafaf469.jpg?v=1765444398","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330901-00-65-05-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}