{"product_id":"bently-nevada-330901-00-78-10-02-00-3300-xl-nsv-proximity-probe","title":"Bently Nevada 330901-00-78-10-02-00 3300 XL NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330901-00-78-10-02-00\u003c\/strong\u003e is a precision-engineered, non-armored \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e featuring a 1\/4-28 UNF thread configuration, serving as a fundamental component of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e. Operating on advanced eddy-current principles, the transducer system generates an output voltage directly proportional to the physical distance between the probe tip and an observed conductive target surface, natively calibrated from the factory to an AISI 4140 steel target. This specialized sensor is intentionally optimized for machinery installations with restricted physical clearance, deep counterbores, side-view constraints, or rear-view tight mounting limits where standard 5 mm and 8 mm proximity probes cannot operate effectively.\u003c\/p\u003e\n\u003cp\u003eWith its compact linear range of 1.5 mm (60 mils), the \u003cstrong\u003e330901-00-78-10-02-00\u003c\/strong\u003e excels in small target applications, such as tracking continuous radial shaft vibration on small rotors under 51 mm (2 in) in diameter or measuring axial thrust displacement on narrow target surfaces below 15 mm (0.6 in). The design integrates a polyphenylene sulfide (PPS) tip via a patented TipLoc molding method to construct a highly stable pressure-sealed bond with the AISI 304 stainless steel probe casing. Mechanically, a patented CableLoc joint anchors the 75-ohm coaxial cable core directly to the tip structure, maintaining up to 220 N (50 lb) of maximum rated pull strength. Terminated with a gold-plated brass ClickLoc connector, the probe provides an automatic locking engagement that maintains contact resistance and electrical continuity despite severe, prolonged industrial machinery vibrations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTight-Clearance Specialization:\u003c\/strong\u003e Explicitly designed for machinery environments with narrow counterbore profiles, side-view limits, or small target profiles where standard 5 mm and 8 mm systems experience field distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall-Diameter Target Tracking:\u003c\/strong\u003e Confirmed operational stability on rotating shaft diameters down to 51 mm (2 in) and flat axial position target surfaces down to 15 mm (0.6 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced TipLoc Molding:\u003c\/strong\u003e Features a highly robust bond connecting the chemical-resistant polyphenylene sulfide (PPS) probe tip directly to the stainless steel body assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated CableLoc Security:\u003c\/strong\u003e Delivers an exceptional 220 N (50 lb) maximum rated tensile pull strength from the probe case to the probe lead wire junction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration-Proof ClickLoc Joints:\u003c\/strong\u003e Employs gold-plated brass coaxial connectors that physically lock into place upon finger-tightening to eliminate the threat of signal dropouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElevated Process Chemical Resistance:\u003c\/strong\u003e Provides enhanced chemical durability compared to historical 3300 RAM series sensors, protecting internal coils across aggressive process compressor fluids.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy System Drop-In Compatibility:\u003c\/strong\u003e Directly compatible and mechanically interchangeable with preceding Bently Nevada 3300 RAM series proximity probe configurations and extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCentrifugal Air Compressors:\u003c\/strong\u003e Continuous monitoring of high-speed impellers, dynamic radial vibration, and thermal shaft expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Refrigeration Compressors:\u003c\/strong\u003e Machinery protection tracking inside small-clearance cooling and process refrigeration equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Gas Compressors:\u003c\/strong\u003e Non-contact machine case displacement and structural orbit monitoring across aggressive oil and gas extraction streams.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTachometer \u0026amp; Zero-Speed Systems:\u003c\/strong\u003e High-frequency pulse monitoring on small, multi-toothed gear configurations to acquire true zero-speed and rotational acceleration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Reference Systems:\u003c\/strong\u003e Generation of once-per-turn Keyphasor timing marks on narrow shaft steps for diagnostic vibration phase profiling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe explicit configuration profile breakdown for the \u003cstrong\u003e330901-00-78-10-02-00\u003c\/strong\u003e metric-fractional probe option is presented below based on factory documentation:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Option Selection\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model: 330901\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Probe, 1\/4-28 UNF thread, without armor \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnthreaded Length Option: 0.0 in \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 78\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Case Length Option: 7.8 in \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal Length Option: 1.0 meter (39 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: Not required \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eElectrical \u0026amp; Performance Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Specification Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Structural Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget Material Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel target (Factory Default Calibration) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Measuring Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils); spans from approx. 0.25 mm (10 mils) to 1.75 mm (70 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately -1 Vdc to -13 Vdc over the linear range \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Average Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% including interchangeability error \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils) over ambient range \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz: +0 dB, -3 dB typical (with up to 305 m \/ 1000 ft field wiring) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Impedance \/ Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe DC Center Resistance (RPROBE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCenter Conductor to Outer Conductor: 4.2 Ohm +\/-0.5 Ohm (for 1.0m probe length) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV output voltage shift per volt change in input voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Flat Target Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum: 8.9 mm (0.35 in); Recommended minimum: 13 mm (0.5 in) diameter \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eMechanical \u0026amp; Material Specifications\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter \/ Specification Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Structural Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Casing Material Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel (SST) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Cable Insulation Core\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ohm coaxial, fluoroethylene propylene (FEP) insulated standard cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Core Build\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass miniature coaxial ClickLoc connectors \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/4-28 Case Installation Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommended: 5.1 Nm (45 in-lb); Maximum Rated: 7.3 Nm (65 in-lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector-to-Connector Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommended: Finger tight; Maximum torque: 0.56 Nm (5 in lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Tensile Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 N (50 lb) structural joint threshold limit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Coaxial Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Differential Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSealed via custom Viton O-ring compound between tip and case \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Component Weight (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 14 to 150 g (0.5 to 5.3 oz) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch4\u003eEnvironmental Limits\u003c\/h4\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eEnvironmental Matrix Condition\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Range Limits\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 Fahrenheit to +351 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Storage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 Fahrenheit to +351 Fahrenheit) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-Temp Seal Operational Constraint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSustained exposure below -34 degC (-30 Fahrenheit) can cause premature pressure seal failure \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Shifts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when cable connectors are protected \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Testing Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully qualified and tested to IEC 68-2-3 damp heat standards \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe electrical interfaces of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e maintain consistent signal conversion throughout the measurement loop:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnection Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \u0026amp; Field Layout Specifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Coaxial Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-integrity coaxial mating point connecting probe lead wire to extension cable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Terminal Blocks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated SpringLoc terminal strips requiring no special field tools.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring Support Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccommodates 0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 with ferrules].\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Return Line Routing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecommends 3-conductor shielded triad cable up to 305 m (1000 ft) maximum.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Adjustment:\u003c\/strong\u003e Manually thread the probe into position until the mechanical clearance distance from the target surface is 1.0 mm (40 mils). Verify via digital voltmeter across the Proximitor output terminals to ensure a baseline reading of approximately -7 Vdc (the midpoint of the linear field range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement Limits:\u003c\/strong\u003e For the 1\/4-28 UNF thread configuration, do not allow the total mechanical thread engagement depth inside the bracket hole to exceed 0.375 inches. Deeper thread engagement past 1.5 times the nominal thread diameter risks binding during installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Hole Preparation:\u003c\/strong\u003e When drilling and tapping field mounting holes for the 1\/4-28 case option, use a #3 or larger tap drill size to avoid thread damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Prevention Distance:\u003c\/strong\u003e To prevent electromagnetic emitted field overlap and erratic measurement errors on small shafts, maintain a minimum probe tip separation distance of 25 mm (1.0 in) for axial alignments or 23 mm (0.9 in) for parallel radial setups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounterbore Clearance Profile:\u003c\/strong\u003e Ensure the surrounding counterbore pocket diameter is at least 9.5 mm (0.375 in) with a recommended minimum of 13 mm (0.5 in). Pocket sizes smaller than 13 mm will modify the scale factor at far gaps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Mating Protocol:\u003c\/strong\u003e Joint connections must be tightened firmly by hand until an audible physical click is registered. If using a tool to mate mixed non-XL brass connectors, do not tighten beyond a maximum torque rating of 0.56 Nm (5 in lb).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMoisture Protection Installation:\u003c\/strong\u003e Apply factory-authorized connector protectors over all cable joints in wet environments. Use supplied silicone tape only in environments without direct, ongoing turbine oil contact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive Compliance:\u003c\/strong\u003e Conforms fully to European Community Directive EMC 2014\/30\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Safety Standards:\u003c\/strong\u003e Fully evaluated under EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive Alignment:\u003c\/strong\u003e Matches compliance metrics for European RoHS Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina RoHS Registration:\u003c\/strong\u003e Certified environmental protection use period (EFUP) designation of 15 years per SJ\/T 11364-2024 regulations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety Certification:\u003c\/strong\u003e Verified for use in safety instrumented systems, achieving SIL 2 capability at HFT=0 and SIL 3 capability at HFT=1.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53356176474475,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330901-00-78-10-02-00.png?v=1780804181","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330901-00-78-10-02-00-3300-xl-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}