{"product_id":"bently-nevada-330902-00-95-05-02-05-3300-nsv-proximity-probes","title":"Bently Nevada 330902-00-95-05-02-05 3300 NSv Proximity Probes","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAn overall case length of 9.5 inches (Option 95) with a fully threaded 1\/4-28 UNF-2A armored case (Option 00) defines the \u003cstrong\u003e330902-00-95-05-02-05\u003c\/strong\u003e \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e. This industrial transducer component utilizes eddy-current technology to execute non-contact displacement measurements on target geometries with restricted clearance or reduced target area.\u003c\/p\u003e\n\u003cp\u003eCompared to the unarmored 330901 variant, the 330902 model incorporates integrated stainless steel armor for robust mechanical protection of the coaxial cable. This specific configuration features a 0.5-meter (20-inch) total length, a standard ClickLoc coaxial connector, and multiple hazardous area approvals, making it compatible with the 330980 Proximitor Sensor and 330930 extension cable in demanding rotating machinery environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 specifies a fully threaded 1\/4-28 UNF-2A probe case with 0.0 inches of unthreaded length.\u003c\/li\u003e\n  \u003cli\u003eOption 95 provides a 9.5-inch overall case length to reach deeply recessed shaft target areas.\u003c\/li\u003e\n  \u003cli\u003eOption 05 designates a short 0.5-meter total probe cable length for tight installation layouts.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides a gold-plated miniature ClickLoc coaxial connector with a standard cable profile.\u003c\/li\u003e\n  \u003cli\u003eOption 05 designates multiple agency approvals certified for hazardous and intrinsically safe zones.\u003c\/li\u003e\n  \u003cli\u003eIntegrated stainless steel armor shields the internal 75-ohm coaxial cabling against mechanical damage.\u003c\/li\u003e\n  \u003cli\u003eViton O-ring pressure seal acts as an environmental barrier between the probe tip and the stainless steel case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurements in small-bore rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eShaft displacement monitoring on high-speed aeroderivative gas turbines.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection applications with limited target geometries and tight structural clearances.\u003c\/li\u003e\n  \u003cli\u003eIndustrial monitoring installations requiring certified intrinsically safe transducer components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330902-00-95-05-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, with stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e95\u003c\/td\u003e\n      \u003ctd\u003e9.5 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meter (20 in) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, and IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e330902-00-95-05-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMechanical Armor\u003c\/td\u003e\n      \u003ctd\u003eIntegrated stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), beginning at approximately 0.25 mm (10 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTarget Calibration\u003c\/td\u003e\n      \u003ctd\u003eCalibrated to AISI 4140 steel (standard)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) with 0 to 45 degC operating range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePressure Sealing\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring between probe tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Pull Strength\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to probe lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the total combined length of the probe (0.5 m) and extension cable matches the calibrated Proximitor Sensor system length.\u003c\/li\u003e\n  \u003cli\u003eUse a maximum installation torque of 5.1 N m (45 in lb) for this 1\/4-28 probe case.\u003c\/li\u003e\n  \u003cli\u003eEnsure the probe cabling is routed away from sharp edges, observing the minimum bend radius of 25.4 mm (1.0 in).\u003c\/li\u003e\n  \u003cli\u003eInstall connector protectors or apply self-fusing silicone tape to prevent moisture or process liquids from entering the coaxial connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEuropean Community Directives: EMC Directive 2014\/30\/EU, RoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT=0), SIL 3 (HFT=1) certified\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals (Option 05): ATEX\/IECEx Class I, Zone 0 (Ex ia IIC T4\/T5 Ga); CSA Class I, Zone 0 (AEx\/Ex ia IIC Ga), Class I, Groups A, B, C, D\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666566541675,"sku":"330902-00-95-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330902-00-95-05-02-05-proximity-probes-445b1hnk4kr_4510fdf1-5ff6-4af2-9bbc-0fdf33e6577e.jpg?v=1765440751","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330902-00-95-05-02-05-3300-nsv-proximity-probes","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}