{"product_id":"bently-nevada-330930-040-03-00-3300-nsv-extension-cable","title":"Удлинительный кабель Bently Nevada 330930-040-03-00 3300 NSv","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330930-040-03-00\u003c\/strong\u003e is a highly specialized \u003cstrong\u003e4.0-meter (13.1 feet) 3300 NSv Proximity Extension Cable\u003c\/strong\u003e. It is engineered as a core component of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e, which is specifically optimized for small shaft targets, limited counterbore clearances, and restrictive side-view geometries common in high-density turbomachinery installations.\u003c\/p\u003e\n\u003cp\u003eDistinct from armored variants, this configuration features a lightweight, high-flexibility coaxial build \u003cstrong\u003ewithout stainless steel armor\u003c\/strong\u003e. It is designed for clean, routed conduit installations or internal machine environments where mechanical shielding is redundant but space-saving and effortless routing are critical. To protect signal integrity, it comes equipped with integrated \u003cstrong\u003econnector protectors\u003c\/strong\u003e over the gold-plated brass \u003cstrong\u003eClickLoc\u003c\/strong\u003e interfaces, preventing moisture or liquid ingress from inducing signal drift at the connection point. This cable seamlessly matches the impedance requirements of the 3300 XL NSv Proximitor Sensor and offers drop-in legacy replacement compatibility for standard 3300 RAM transducer lines.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4.0-Meter Length Optimization:\u003c\/strong\u003e Accurately calibrated to build standard 5.0m or 7.0m total system lengths when paired with matching 1.0m or 3.0m NSv probes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnarmored Design (03 Option):\u003c\/strong\u003e Strips away bulky outer stainless steel armor to offer maximum flexibility, a tighter effective installation volume, and lighter weight—ideal for densely packed conduit routing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegral Connector Protectors:\u003c\/strong\u003e Features pre-installed boots over the miniature connectors to ensure long-term shielding against turbine oils and humidity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClickLoc Interlocking Interconnects:\u003c\/strong\u003e Equipped with gold-plated brass ClickLoc connectors that lock into place, preventing accidental loosening under severe high-frequency machinery vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExceptional EMI\/RFI Shielding:\u003c\/strong\u003e The 75-ohm FEP insulation core effectively isolates weak proximity signals from industrial electro-magnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Legacy Upgrades:\u003c\/strong\u003e Backwards mechanically and electrically interchangeable with traditional Bently Nevada 3300 RAM sensor extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall Shaft Eddy-Current Measurements:\u003c\/strong\u003e Radial vibration and shaft position monitoring on rotating machinery with shaft diameters under 51 mm (2.0 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTight-Clearance Turbomachinery:\u003c\/strong\u003e Centrifugal air compressors, process gas compressors, and industrial refrigeration compressors with constrained internal probe mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThrust Measurements on Small Targets:\u003c\/strong\u003e Axial position tracking on flat target surfaces smaller than 15 mm (0.6 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine Supervisory Instrumentation (TSI):\u003c\/strong\u003e Speed sensing, zero-speed gating, and phase reference (Keyphasor) signal routing within clean-conduit networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe exact breakdown of the \u003cstrong\u003e330930-040-03-00\u003c\/strong\u003e model code structure is as follows:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Block\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Connector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eWithout stainless steel armor, with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot Required \/ Standard Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Coaxial Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohms (System output resistance 50 ohms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Core material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFluoroethylene Propylene (FEP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Protection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Unarmored core)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Core Finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Interface Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated up to 220 N (50 lb) pull strength at the connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 inch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Operational Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.18 kg (Lightweight configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Envelope\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% Condensing\/Humidity when utilizing connector protectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance and System Tuning:\u003c\/strong\u003e Ensure the overall total electrical length of the proximity probe and this 4.0m extension cable matches the specification labeled on the 3300 XL NSv Proximitor Sensor (typically 5.0m or 7.0m total system lengths).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Torque Limit:\u003c\/strong\u003e Secure the ClickLoc connectors finger-tight until they lock. Do not use heavy-handed mechanical tools to tighten, as excess torque can damage the internal gold-plated pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Bend Safeguards:\u003c\/strong\u003e Always maintain a layout route with a minimum bend radius of 25.4 mm. Sharp pinching or kinking on unarmored FEP cables can permanently alter cable capacitance, destroying calibration accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealing Application:\u003c\/strong\u003e Slide the integrated connector protector firmly over the mated connection to guarantee an airtight, fluid-resistant boundary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directive:\u003c\/strong\u003e 2014\/30\/EU Compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e 2011\/65\/EU and China RoHS (15-year EFUP designation).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional Safety Standards:\u003c\/strong\u003e SIL 2 capable when integrated into approved safety instrumented loops.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666619167083,"sku":"330930-040-03-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-040-03-00-3300-nsv-extension-cable-no4whhwez14_c248ff6c-be59-4f65-8727-29ec5867037c.jpg?v=1765444235","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330930-040-03-00-3300-nsv-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}