{"product_id":"bently-nevada-330930-060-04-05-3300-nsv-extension-cable","title":"Удлинительный кабель Bently Nevada 330930-060-04-05 3300 NSv  ","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330930-060-04-05\u003c\/strong\u003e specifies a 6.0-meter \u003cstrong\u003e3300 NSv extension cable\u003c\/strong\u003e equipped with stainless steel armor, a protective FEP jacket, and an integrated connector protector. This specific option configuration provides physical defense and environmental shielding in tight-clearance industrial applications where smaller target sizes or compact mounting profiles restrict standard transducer installation. The cable connects a 3300 NSv proximity probe to a compatible 3300 XL NSv Proximitor Sensor to complete the non-contact displacement measurement loop.\u003c\/p\u003e\n\u003cp\u003eUnlike standard unarmored configurations (Option 00) or unjacketed armored variants (Option 02), this cable uses a rugged fluorinated ethylene propylene (FEP) jacket over stainless steel armor to resist corrosive chemical exposure and mechanical abrasion. Additionally, the pre-installed fluorosilicone connector protector prevents moisture and fluid contamination at the critical probe-to-cable junction, while Option 05 approvals permit installation in hazardous areas.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 060 specifies a 6.0-meter (19.7 feet) total cable length, matching the required system calibration profile.\u003c\/li\u003e\n  \u003cli\u003eOption 04 delivers integrated stainless steel armor with a protective FEP outer jacket to shield the internal coaxial line from physical damage and chemical deterioration.\u003c\/li\u003e\n  \u003cli\u003eFluorosilicone connector protector pre-installed on the female end prevents moisture, turbine oil, and debris ingress at the probe-to-cable connection point.\u003c\/li\u003e\n  \u003cli\u003eOption 05 compliance provides multiple global hazardous area certifications for explosive environments.\u003c\/li\u003e\n  \u003cli\u003eCoaxial 75 ohm FEP-insulated construction maintains constant impedance to avoid signal distortion across the measurement path.\u003c\/li\u003e\n  \u003cli\u003eMiniature coaxial ClickLoc connectors ensure secure coupling with positive tactile engagement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSmall-bore steam and gas turbines\u003c\/li\u003e\n  \u003cli\u003eHigh-speed machinery with limited target geometry\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines\u003c\/li\u003e\n  \u003cli\u003eCentrifugal compressors and pumps with tight mechanical clearances\u003c\/li\u003e\n  \u003cli\u003eShaft vibration, axial position, and radial offset monitoring in hazardous process areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Extension Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e060\u003c\/td\u003e\n      \u003ctd\u003e6.0 meters (19.7 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB: Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003eWith stainless steel armor, with FEP jacket, with connector protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including ATEX, IECEx, and North American hazardous area certifications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330930\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohms nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eCenter conductor: 0.220 ohm\/m (0.067 ohm\/ft)\u003cbr\u003eShield: 0.066 ohm\/m (0.020 ohm\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Outer Diameter (O.D.)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.80 mm (0.11 in) maximum (base cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmored Outside Diameter (O.D.)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.6 mm (0.30 in) maximum (FEP jacketed armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFerrule Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.4 mm (0.33 in) maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc coaxial connectors (one male, one female)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFinger tight recommended; 0.56 N m (5 in lb) maximum torque\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFluorosilicone connector protector pre-installed on female end\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmored Cable Unit Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e64 g\/m (0.7 oz\/ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the 3300 NSv extension cable, observe the following engineering practices:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDo not exceed the minimum cable bend radius of 25.4 mm (1.0 in) to prevent internal damage or impedance changes in the coaxial core.\u003c\/li\u003e\n  \u003cli\u003eEnsure the female connector on the extension cable is securely mated to the male connector of the proximity probe. Tighten connections to finger-tight, or a maximum of 0.56 N m (5 in lb) if using a torque wrench. Do not use pliers or other unrated tools.\u003c\/li\u003e\n  \u003cli\u003ePosition the pre-installed fluorosilicone connector protector over the mated connection to shield the electrical contacts from fluids, moisture, and particulate ingress. Avoid using silicone tape inside machine casings or where direct exposure to turbine oil is expected.\u003c\/li\u003e\n  \u003cli\u003eRoute the cable through dedicated conduit or cable trays to isolate it from electromagnetic interference (EMI) and physical hazards. Maintain physical separation from high-voltage AC power lines.\u003c\/li\u003e\n  \u003cli\u003eEnsure the combined length of the proximity probe and the extension cable matches the calibrated total system length required by the 3300 XL NSv Proximitor Sensor (typically 5.0 meters or 7.0 meters).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv extension cable with Option 05 satisfies multiple global standards for industrial safety and hazardous area installations:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNorth American Approvals (cNRTLus):\u003c\/strong\u003e Intrinsically safe for Class I, Zone 0, AEx\/Ex ia IIC Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III. Non-incendive for Class I, Zone 2, AEx\/Ex nA\/ec IIC Gc; Class I, Division 2, Groups A, B, C, D.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX \u0026amp; IECEx:\u003c\/strong\u003e Intrinsically safe Ex ia IIC T4\/T5 Ga; Ex ia IIIC T90C\/T105C Dc. Non-sparking\/increased safety Ex nA IIC T4\/T5 Gc; Ex ec IIC T4\/T5 Gc.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunctional Safety:\u003c\/strong\u003e SIL 2 certified (HFT = 0) or SIL 3 certified (HFT = 1) when integrated into a safety instrumented system following standard guidelines.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e CE mark, European Union RoHS Directive 2011\/65\/EU, and China RoHS compliant (15-year EFUP designation).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666636599659,"sku":"330930-060-04-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-060-04-05-3300-nsv-extension-cable-wc1tcj54xm3_dad2b412-1644-4674-ba0b-5222d6e47944.jpg?v=1765444486","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-330930-060-04-05-3300-nsv-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}