{"product_id":"bently-nevada-3500-61-01-cn-3500-series-temperature-monitor-module","title":"Bently Nevada 3500\/61-01-CN 3500 Series Temperature Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eProcessing continuous RTD and thermocouple inputs within the 3500 rack architecture, the \u003cstrong\u003eBently Nevada 3500\/61-01-CN\u003c\/strong\u003e acts as a high-density temperature monitoring module designed for machinery protection. This module continuously compares input temperatures against configured alarm setpoints to guard critical industrial assets. The \u003cstrong\u003e3500\/61-01-CN\u003c\/strong\u003e features non-isolated I\/O channels with internal terminations, streamlining panel integration by removing the need for external terminal blocks. Certified for China-specific agency requirements (CN option), this monitor integrates seamlessly with standard 3500 Rack Configuration Software to provide reliable thermal asset tracking.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eAccepts both Resistance Temperature Detector (RTD) and Thermocouple (TC) inputs.\u003c\/li\u003e\n  \u003cli\u003eNon-isolated I\/O module configuration featuring internal terminations to reduce overall cabinet space requirements.\u003c\/li\u003e\n  \u003cli\u003eProvides continuous, real-time comparisons of field inputs against user-defined Alert and Danger setpoints.\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard Bently Nevada 3500 Series machinery protection system racks.\u003c\/li\u003e\n  \u003cli\u003eIncludes recorder outputs to transmit processed temperature variables to external plant recorders or control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSteam, gas, and hydro turbine bearing temperature monitoring.\u003c\/li\u003e\n  \u003cli\u003eLarge electric motor stator winding and winding temperature protection.\u003c\/li\u003e\n  \u003cli\u003eGenerator core, exciter, and transformer thermal monitoring.\u003c\/li\u003e\n  \u003cli\u003eReciprocating compressor cylinder head and discharge valve temperature tracking.\u003c\/li\u003e\n  \u003cli\u003eHeavy industrial pumps and gearbox casing thermal guards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2d3748;\"\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem;\"\u003eSpecification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3500\/61-01-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eModule Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eTemperature Monitor with Recorder Outputs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eI\/O Module Type\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e01 = RTD\/TC Non-Isolated I\/O Module, Internal Terminations\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCN = Country-specific approvals (China)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States (Made in U.S.A)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold;\"\u003eShipping Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e2.0 kg (4.4 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe \"01\" internal termination suffix is physically distinct from the \"02\" external termination module. If you are retrofitting an older installation that utilized external termination blocks, you cannot reuse the same direct internal wiring terminations without removing the external connection cabling. Ensure your rack physical layout supports direct panel routing to the rear of the 3500 rack when using the 3500\/61-01-CN.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eBecause this module utilizes non-isolated channels, all connected RTD and Thermocouple sensor sheaths must be electrically isolated from earth ground at the measurement point. Mixing grounded thermocouples or unisolated RTD elements on the same 3500\/61-01-CN module can create ground loops, resulting in severe signal fluctuations, temperature drift, or false Danger level machinery trips.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen configuring RTD sensors, ensure that three-wire configuration is active and that lead-resistance matching is performed inside the 3500 Configuration Software. For long field runs, uncompensated lead resistance will create an artificial positive temperature offset, causing the system to read consistently higher than actual machinery metal temperatures.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e De-energize the entire 3500 rack power supply system before inserting or removing the I\/O module. Performing hot insertion of non-isolated terminal components can damage sensitive internal processing circuits or trigger false trip signals to associated Emergency Shutdown (ESD) logic.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eVerify that the 3500\/61 main monitor module slot matches the backplane slot where the 3500\/61-01-CN I\/O module will be installed.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eSlide the I\/O module firmly along the chassis guide rails until the backplane connectors seat completely.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eTighten the two integrated chassis thumbscrews on the faceplate to secure the module and establish proper ground contact.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 2rem; height: 2rem; display: flex; align-items: center; justify-content: center; font-weight: bold;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0;\"\u003eConnect the RTD or Thermocouple field wiring to the terminal block, ensuring correct polarity and shielding integrity.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307603819,"sku":"3500\/61-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350061-01-CN-ls515xj2f5y_45df22ef-c683-4cf7-8b6e-c6a415a22590.jpg?v=1765520724","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-3500-61-01-cn-3500-series-temperature-monitor-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}