{"product_id":"bently-nevada-84661-66-330750-series-interconnection-cables","title":"Bently Nevada 84661-66 330750 Series Interconnection Cables","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e84661-66\u003c\/strong\u003e specifies a 66-foot (20.1 m) standard armored \u003cstrong\u003einterconnection cable\u003c\/strong\u003e used with the Bently Nevada 330750 High Temperature Velomitor System (HTVS) to link the sensor conditioning electronics to the machinery monitor. This cable construction consists of stainless steel armor over a shielded 0.382 mm2 (22 AWG) twisted pair cable, providing high mechanical protection in harsh industrial environments. It is fitted with a moisture-resistant female connector at the HTVS transducer end and terminated with ring lugs at the monitor or receiver end.\u003c\/p\u003e\n\n\u003cp\u003eUnlike the unarmored 9571-NN standard interconnect cable, the 84661-66 variant integrates a flexible stainless steel conduit armor to protect the inner conductors against mechanical abrasion, crushing forces, and environmental degradation. This 66-foot cable configuration allows operators to position sensitive condition-monitoring electronics up to 20.1 meters away from high-temperature machinery surfaces, maintaining stable vibration signals without thermal degradation of the transmitter.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e66-foot (20.1 m) overall cable length provides flexible routing from high-temperature machinery locations to cool electronics or termination enclosures.\u003c\/li\u003e\n  \u003cli\u003eStainless steel armor wrapping protects the 22 AWG inner conductors against severe abrasion, impact, and mechanical routing hazards.\u003c\/li\u003e\n  \u003cli\u003eShielded 0.382 mm2 (22 AWG) twisted pair copper conductors maintain signal integrity and reduce electromagnetic and radio frequency interference.\u003c\/li\u003e\n  \u003cli\u003eMoisture-resistant female connector pre-installed at the HTVS transducer end ensures a sealed connection.\u003c\/li\u003e\n  \u003cli\u003ePre-terminated ring lugs at the monitor end facilitate secure screw-terminal connection inside monitoring panels.\u003c\/li\u003e\n  \u003cli\u003eOperating temperature range of -29 degC to 121 degC (-20 degF to 250 degF) covers most industrial routing paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration and axial position measurement on industrial machinery using the 330750 High Temperature Velomitor System.\u003c\/li\u003e\n  \u003cli\u003eHigh-temperature processing environments including steam turbines, gas turbines, and industrial piping where physical protection of cabling is required.\u003c\/li\u003e\n  \u003cli\u003ePetrochemical, power generation, and steel manufacturing plants with high mechanical abuse risks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e84661\u003c\/td\u003e\n      \u003ctd\u003eStandard Armored Interconnect Cable (with stainless steel armor, shielded 22 AWG cable, moisture-resistant female connector at HTVS end, ring lugs at monitor end)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOption NN (Length)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e66\u003c\/td\u003e\n      \u003ctd\u003e66 feet (approximately 20.1 meters) overall cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e84661-66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard Armored Interconnect Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.382 mm2 (22 AWG)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eShielded twisted pair\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStainless steel armor sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector (Transducer End)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMoisture-resistant 2-pin female connector (compatible with HTVS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTermination (Monitor End)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRing lugs (\"A\" White, \"B\" Black, \"SHLD\" Green)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-29 degC to 121 degC (-20 degF to 250 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOverall Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e66 ft (approx. 20.1 m) +\/- 6.0 in (152.4 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Interconnect Run\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e305 m (1000 ft) max for High Temperature Velomitor System (HTVS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eWire \/ Terminal\u003c\/th\u003e\n      \u003cth\u003eFunction \/ Color\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003eWhite (Signal +)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eBlack (Signal - \/ Return)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSHLD\u003c\/td\u003e\n      \u003ctd\u003eGreen (Shield Ground)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUse shielded cabling to minimize electrostatic and electromagnetic noise.\u003c\/li\u003e\n  \u003cli\u003eEnsure the stainless steel armored jacket is securely tied down along the run using cable clamps.\u003c\/li\u003e\n  \u003cli\u003eAvoid routing in areas where the ambient temperature exceeds 121 degC (250 degF) to preserve cable insulation.\u003c\/li\u003e\n  \u003cli\u003eTerminate the green shield wire to the appropriate monitor ground or instrument ground. Do not ground both ends of the shield to prevent ground loops.\u003c\/li\u003e\n  \u003cli\u003eAvoid tight bends or pinching of the stainless steel armor to prevent inner conductor damage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Fully compatible with Bently Nevada 330750 High Temperature Velomitor System (HTVS) which supports ATEX\/IECEx (Ex ia IIC or IIB, Ex ec IIC or IIB) and CSA\/UL certifications when installed in accordance with system guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531709291,"sku":"84661-66","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-84661-66-velomitor-interconnect-cable-ujczhwzxg3n_0446cfb7-f752-4485-ad5d-78a8ab91d293.jpg?v=1765440365","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-84661-66-330750-series-interconnection-cables","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}