{"product_id":"bently-nevada-9571-17-interconnect-cable","title":"Bently Nevada 9571-17 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eThe Bently Nevada 9571-17 is a heavy-duty, standard interconnect cable assembly optimized for industrial machinery condition monitoring and vibration tracking loops. Engineered with a \u003cstrong\u003e2-conductor twisted, shielded pair\u003c\/strong\u003e configuration utilizing high-grade 22 AWG conductors, this rugged assembly serves as the key signal link between transducers—such as the Velomitor piezo-velocity sensors or specialized low-frequency accelerometers—and proximity or vibration monitors. It features an integrated 2-socket moisture-resistant female connector at the sensor-facing terminus and prepared terminal ring lugs at the backend interface for clean cabinet termination. Designed to handle severe industrial conditions, this instrumentation cable provides optimal shielding attenuation to reject electromagnetic interference (EMI) and radio frequency interference (RFI) across extended field runs. The option code 17 specifies a precise fixed length of 17 feet (5.2 meters) to maintain consistent impedance control within customized system layouts without extra coil accumulation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTwisted-Pair Shielded Construction:\u003c\/strong\u003e 22 AWG double-conductor design minimizes inductive crosstalk and cross-talk noise across long industrial signal runs.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMoisture-Resistant Connection:\u003c\/strong\u003e Outfitted with an overmolded 2-socket female connector on the field terminus to prevent liquid ingress in humid environments.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePre-Terminated Monitor Lugs:\u003c\/strong\u003e Features durable terminal ring lugs at the cabinet side for direct connection onto terminal strips without field crimping.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Thermal Envelope:\u003c\/strong\u003e Rated to withstand continuous operational temperature exposures ranging from -29 degC to +121 degC.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eOptimized System Length:\u003c\/strong\u003e Pre-cut 17-foot option prevents excess loop storage while satisfying point-to-point field bridging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 20px; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eInterconnecting Velomitor piezo-velocity sensors with remote diagnostic monitors or continuous monitoring racks.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eMachinery monitoring systems in oil and gas extraction facilities, petrochemical refining complexes, and municipal pumping stations.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eCritical absolute casing vibration loops on high-speed rotating equipment, large cooling fans, and industrial pumps.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 8px;\"\u003eField routing within protective conduit tracks where severe EMI interference requires high-integrity drain shields.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eModel Code\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eConfiguration Option\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eTechnical Value Description\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e9571\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBase Assembly Model\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eStandard Interconnect Cable (2-Conductor, 22 AWG, Shielded)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003e-17\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCable Length Designation\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e17 feet (5.2 meters) continuous length\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 20px;\"\u003e\n  \u003ctable style=\"width: 100%; border-collapse: collapse; color: #2d3748; text-align: left;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #1a365d;\"\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; color: #1a365d;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eConductor Gauge\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e22 AWG (0.382 mm2)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCore Arrangement\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2-conductor twisted pair with integrated drain wire\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eField Connection End\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2-socket moisture-resistant female molded connector\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMonitor Connection End\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePre-installed ring terminal lugs\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature Range\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-29 degC to +121 degC (-20 degF to +250 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMaximum Allowed System Loop\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e305 meters (1000 feet) maximum total run when matched with approved sensor\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eApplication Constraints\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eNot for use inside the 21128 Velocity Transducer Housing\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (A Baker Hughes Company)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eU.S.A.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e2.0 Kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003ePackage Dimensions (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e280 mm x 280 mm x 25 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 15px; margin-bottom: 20px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 5px;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and fully de-energize the machine monitoring system loop prior to pulling, routing, or terminating instrumentation wiring. Handling live field signals near high-energy machinery sections can induce dangerous system loop faults, trigger accidental process shutdowns, or create electrical discharge hazards.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color: #2d3748; margin-bottom: 15px;\"\u003eField engineers must strictly observe the following professional connection sequence:\u003c\/p\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e1\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eRoute the cable through dedicated, grounded steel conduit lines to isolate the 22 AWG twisted pairs from high-voltage motor power feeds.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e2\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eInspect the 2-socket moisture-resistant female head for any contaminants, debris, or moisture prior to mating with the sensor housing connector receptacle.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e3\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eEngage the female thread assembly tightly onto the sensor receptacle to create a fully sealed environmental barrier against liquid ingress.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"margin-bottom: 15px; display: flex; align-items: flex-start;\"\u003e\n  \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; border-radius: 50%; min-width: 24px; height: 24px; display: flex; align-items: center; justify-content: center; font-weight: bold; margin-right: 12px; margin-top: 2px;\"\u003e4\u003c\/div\u003e\n  \u003cdiv style=\"color: #2d3748;\"\u003eLand the backend ring terminal lugs securely on the terminal blocks inside the panel enclosure, anchoring the shield wire to the designated instrumentation ground point.\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666534232427,"sku":"9571-17","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-9571-17-interconnect-cable-l321dmvfk5l_98ba226c-f49e-40a1-bad8-c775e9af6fc1.jpg?v=1765440398","url":"https:\/\/www.plcprotech.com\/ru\/products\/bently-nevada-9571-17-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}