{"product_id":"general-electric-is200vaich1dbc-mark-vi-vme-analog-input-card","title":"General Electric IS200VAICH1DBC Mark VI VME Analog Input Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200VAICH1DBC\u003c\/strong\u003e functions as an VME Analog Input Card developed by General Electric as an integral component of the Mark VI control system. This VME board is engineered to process large volumes of instrumentation signals, accepting up to 20 analog inputs and regulating 4 analog outputs across critical industrial processes. Deployed within a VME rack structure, the board routes digitized real-time sensor measurements over the VME backplane framework to the system controller, permitting precise monitoring and closed-loop control interface execution.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200VAICH1DBC\u003c\/strong\u003e features full structural support for both simplex and Triple Modular Redundant (TMR) operational layouts. In a high-reliability TMR network setup, field signals are distributed across three separate racks each housing an individual analog card, utilizing integrated voting and diagnostic check monitoring circuits to maintain precise current outputs even during single hardware board faults. In simplex layouts, the assembly acts as the sole processing path handling input scaling and output current tracking for the connected application loop.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Channel Instrumentation Density:\u003c\/strong\u003e Provisions 24 independent channels optimized to balance multi-point monitoring constraints within central process frames.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Dual-Redundancy Configurations:\u003c\/strong\u003e Operates seamlessly across simplex architectures or fault-tolerant Triple Modular Redundant (TMR) architectures with automatic isolation control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElevated Output Driving Potential:\u003c\/strong\u003e Engineered with upgraded drive circuitry providing up to 18 V at the external terminal screw contact paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended Load Signal Balancing:\u003c\/strong\u003e Supports operation into higher impedance circuits with a maximum load handling capability of up to 800 ohm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Hardware Interrogation:\u003c\/strong\u003e Interacts with the local terminal card ID device to run automatic mismatch checking routines, creating immediate system faults upon detecting technical hardware conflict.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMark VI central VME control rack instrumentation inputs\u003c\/li\u003e\n\u003cli\u003eHigh-density analog monitoring and actuator drive management\u003c\/li\u003e\n\u003cli\u003eFault-tolerant Triple Modular Redundant (TMR) control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS200VAICH1DBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVME Analog Input Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrive Voltage Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 18 V at terminal screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Handling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 800 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLess than 31 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.04 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.99 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.73 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States of America (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTerminal Board Compatibility\u003c\/h3\u003e\n\u003cp\u003eTo ensure optimal integration, this generation of the Analog Input Card requires specific terminal interface cards. Compatible terminal configurations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTBAIH1C\u003c\/strong\u003e or later revised terminal versions\u003c\/li\u003e\n\u003cli\u003eAny functional revision of the \u003cstrong\u003eSTAI\u003c\/strong\u003e terminal board assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVME Rack Alignment:\u003c\/strong\u003e Slide the card assembly firmly into its targeted slot inside the VME chassis enclosure, ensuring full engagement with the VME backplane pins prior to securing panel screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Interface Connection:\u003c\/strong\u003e Connect robust interface cables from the VME rack directly to the compatible \u003cstrong\u003eTBAIH1C\u003c\/strong\u003e or \u003cstrong\u003eSTAI\u003c\/strong\u003e terminal boards to ensure uncorrupted signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configurations:\u003c\/strong\u003e When executing extended load operations up to 800 ohm, pair the circuit installation with up to 1000 ft of #18 wire to secure reliable operational margins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695409295723,"sku":"IS200VAICH1DBC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is200vaich1dbc-analog-i-o-board-aplviy10yas_026674c8-4b56-4d8f-8398-564a18901b57.jpg?v=1766135000","url":"https:\/\/www.plcprotech.com\/ru\/products\/general-electric-is200vaich1dbc-mark-vi-vme-analog-input-card","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}