{"product_id":"general-electric-is210mvrbh1a-mark-vie-i-o-interface-board","title":"General Electric IS210MVRBH1A Mark VIe I\/O Interface Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS210MVRBH1A\u003c\/strong\u003e is an I\/O interface board designed to function seamlessly within the Mark VIe control system. This printed circuit board (PCB) serves as a dedicated communication and connectivity hub, typically operating in conjunction with the PMVE input-output pack to process analog and digital signals. To maintain system reliability, the board features an integrated temperature sensor with an accuracy of 2 Celsius. If temperatures exceed predefined thresholds, the system automatically triggers a diagnostic alarm and logs the condition into the database (signal space) to support subsequent control actions or plant messages. Because each associated I\/O pack communicates independently on the IONet, the \u003cstrong\u003eIS210MVRBH1A\u003c\/strong\u003e supports individual pack replacement without interrupting other active I\/O modules or requiring the removal of existing field wiring.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfigured specifically for R\/S\/T ADIO (Analog\/Digital Input\/Output) device interfacing.\u003c\/li\u003e\n\u003cli\u003eFacilitates real-time, bidirectional communication and data routing within the control network.\u003c\/li\u003e\n\u003cli\u003eProvides full compatibility with the Mark VIe control system architecture.\u003c\/li\u003e\n\u003cli\u003eModular engineering allows for direct hot-swapping of connected I\/O packs.\u003c\/li\u003e\n\u003cli\u003eUtilizes the Unit Data Highway (UDH) protocol for high-speed inter-module data exchange.\u003c\/li\u003e\n\u003cli\u003eExtends overall signal, sensor, and actuator capacity when combined with PMVE packs.\u003c\/li\u003e\n\u003cli\u003eSupports fault-tolerant architectures through integrated network-wide alerting and data processing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas turbine control systems\u003c\/li\u003e\n\u003cli\u003eSteam turbine monitoring and regulation\u003c\/li\u003e\n\u003cli\u003eDistributed Control Systems (DCS) in power generation\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and process control plants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIS210MVRBH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCB (I\/O Interface Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.75 x 9.50 x 3.50 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Sensor Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Celsius (3.6 Fahrenheit for connected packs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUDH (Unit Data Highway) \/ IONet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Manufacture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure appropriate grounding and shielding practices are maintained at the terminal board to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eAvoid routing high-voltage field wiring parallel to low-voltage network cables within the enclosure.\u003c\/li\u003e\n\u003cli\u003eRely on free convection cooling by leaving adequate ventilation space around the board assembly.\u003c\/li\u003e\n\u003cli\u003eConnected I\/O packs can be plugged in or replaced without removing the underlying field wiring from the interface board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMay comply with safety instrumented system standards such as ISA S84 or IEC 61508 depending on total system configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52695418143083,"sku":"IS210MVRBH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/general-electric-is210mvrbh1a-i-o-interface-board-4c4h0rdyou5_8f5eb6de-32d9-410d-a825-73696da45ab5.jpg?v=1766135314","url":"https:\/\/www.plcprotech.com\/ru\/products\/general-electric-is210mvrbh1a-mark-vie-i-o-interface-board","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}